m
PO2
O2%
OLF
Fig. 3.20 Nitrox display. The
maximum depth based on set
O
% (21%) and PO
(1.4 bar) is
2
2
54.1 m [177 ft].
m
O2%
OLF
°
C
DIVE
TIME
Fig. 3.21 Surface display in the
NITROX Mode.
28
WARNING!
IF YOUR DIVE COMPUTER IS INSTALLED
IN A CONSOLE, DO NOT EXPOSE THE PRES-
SURE GAUGE TO ANY GAS MIX CONTAIN-
ING MORE THAN 40% OXYGEN! Enriched air
with greater oxygen content may present a risk of
fi re or explosion and serious injury or death.
DEFAULT NITROX SETTINGS
In the NITROX Mode, when set to standard air
(21% O
), the instrument can be used as an air dive
2
computer. It remains in this air mode until the O
setting is adjusted to any other percentage of oxygen
(22% - 50%).
NOTE! The computer will automatically revert to
the air (21% O
) setting when a new dive series is
2
started, if it is not set to any other mix during the
last two hours. When the oxygen percentage is set
for air, the computer will retain this setting.
Manually entered values for oxygen percentage are
retained for about two hours after the setting if a dive
series has not started. In case a dive series is started,
the set value is retained until a new dive series is
started or a new value is entered manually.
The default setting for maximum oxygen partial
pressure is 1.4 bar, however you are able to set it
between the range of 1.2 - 1.6 bar.
%