Menu
Type
Service 708
Service 608
OSD Level
Audio Level Meter
Audio CH
Position
Transparency
Peak Hold
Time Code
VITC/LTC
Position
Password
Change Password
76
System Configuration Menu
Function and operation ([
Sets the closed caption type.
[Auto1]: Select to set to 608(VBI) when the SD-SDI signal is input or 708 when the HD-
SDI signal is input.
Auto2: Select to set to 608(VBI) when the SD-SDI signal is input or 608(708) when the
HD-SDI signal is input.
708: Select to display the closed caption signal of the EIA/CEA-708 standards.
608 (708): Select to display the closed caption signal of the EIA/CEA-608 standards
transmitted by EIA/CEA-708 standards.
608 (ANC): Select to display the closed caption signal of the EIA/CEA-608 standards
transmitted as the ancillary data
608 (VBI): Select to display the closed caption signal of the EIA/CEA-608 standards
transmitted by using the line 21.
Sets Service when Type is set to 708.
You can select from Service1 to Service6. [Service1]
Sets Service when Type is set to 608 (VBI), 608 (ANC) or 608 (708).
You can select from CC1 to CC4 or Text1 to Text4. [CC1]
Sets the luminance of the letter.
You can select from [100IRE] (bright), 50IRE or 30IRE (dark).
Sets the audio level meter.
When the BKM-250TG is installed, you can select the item.
The setting is effective for the input signal of the BKM-250TG.
Note
As the audio level meter is superimposed on the video signal, the audio level meter may be
cut partially because of the scan mode setting of the monitor.
Sets the audio channel.
You can select from [CH1-CH8] or CH9-CH16.
Sets the display position of the audio level meter.
You can select from [Bottom] (bottom) or Top (top).
Sets the transparency of the background of the audio level meter.
You can select from [Black] (black) or Half (translucence).
Sets the peak hold mode of the audio level meter.
[Off]: The peak hold does not function.
Auto: The peak hold is automatically released after about 1 second.
Manual Reset: The peak hold is released manually.
To release the peak hold, select ALM Hold Reset (page 71) in the Function Switch menu
of the Display Function menu or set ALM Hold Reset to on by pressing the ALM Hold
Reset button* of the controller.
* ALM Hold Reset is assigned to the controller in the Function Key menu (page 84) of
the Controller menu.
Sets the time code.
When the BKM-250TG is installed, you can select the item.
The setting is effective for the input signal of the BKM-250TG.
Note
As the time code is superimposed on the video signal, the time code may be cut partially
because of the scan mode setting of the monitor.
Sets the type of the time code.
You can select from [VITC] or LTC.
Sets the display position of the time code.
You can select from Top Left (top left), [Top Center] (top center), Top Right (top right),
Bottom Left (bottom left), Bottom Center (bottom center) or Bottom Right (bottom right).
Sets the password for the menu.
Enter a four-digit number for the password. [9999]
Changes the password.
Enter New Password: Enter a new password with the numeric buttons and press the
ENTER (Ent) button.
Re-Enter Password: Enter the new password again and press the ENTER (Ent) button.
The password is registered.
To change it, press the MENU button.
]: factory setting)