SPECIFICATIONS

• Sensor: UV spectrum absorption
• Sensor life: 10 years
• Alarm mode: visual and audible
• Display: high resolution bright TFT active matrix LCD
• Automatic shutdown: 10 minutes without operation
• Operating temperature: -10 to 52˚C (14 to 125.6˚F)
• Operating relative humidity: 50% to 85% RH
• Storage temperature: -20 to 60˚C (-4 to 140˚F)
• Probe length: 14.37"
• Battery: 3.78V 3000mAh lithium battery (rechargeable) (6 hours of detection)
• Weight: 15 oz.
• Size: 7.8 x 3 x 1.5"
WARNING!!
• Wear Safety Glasses / Wear Gloves
• Please install clean filter before detection, otherwise it may damage the sensor
• Please charge the detector promptly to ensure sufficient battery level
• Do not touch or detect any charged objects using the probe
• Do not let water enter the air inlet of the probe
• Please avoid breathing the refrigerant vapors. Inhalation of high concentrations of refrigerant is harmful and may
cause unconsciousness or death.
• The detector has a built-in rechargeable lithium battery, please do not change to other battery types
BUTTONS & DISPLAY
BUTTONS
: Press and hold for 2 seconds to turn on the detector; press again to turn it off
• SENS: Press to select preferred sensitivity level (low, medium and high)
• MUTE: Press to turn on/off the buzzer
• REF: Press to select ALL REF (default setting), R134a, R404a, R407C, R410A or R1234yf
• PEAK: Press and release to mark or unmark the maximum leak. If unmarked, the peak value will be cleared
DISPLAY
1. ALARM: Indicates alarm status. red icon: disabled; green icon: enabled
2. PEAK VALUE: Indicates the maximum detected leak
Note: PEAK function must be on or it will not show peak value
3. LEAK VALUE: Indicates the current detected leak. The higher the leak concentration, the
higher the bars
4. SENSITIVITY LEVEL: Displays current sensitivity level. 3 levels are available for different
needs. H: high sensitivity; M: medium sensitivity; L: low sensitivity
5. SMART SENSOR: Displays current refrigerant selection
6. BATTERY LEVEL: Displays current battery level
Green: full battery; Yellow: low battery; Red: extreme-low battery, please charge as soon
as possible
7. PEAK ON/OFF: Indicates peak function status. The display shows on or off to indicate the
peak function is enabled
or disabled (turning off peak will clear all recorded peak values).
8. Charging and status indicator