Dryer Venting Requirements - Maytag MDE17CSBGW Installation Instructions Manual

Commercial electric dryer
Hide thumbs Also See for MDE17CSBGW:
Table of Contents

Advertisement

Available languages

Available languages

WARNING: Toreducetheriskoffire,thisdryerMUSTBE
EXHAUSTEDOUTDOORS.
IMPORTANT: Observeallgoverningcodesandordinances.
Followingtheseventingrequirementswillminimiseducting
air noise.
Adequateventilationhastobeprovidedtoavoidthe
backflowofgasesintotheroomfromappliancesburning
otherfuels,includingopenfires(i.e.availableairflowinto
theroomshouldmatchairflowoutfromtheroom).
Dryerexhaustmustnotbeconnectedintoanygasvent,
chimney,wall,ceiling,attic,crawlspace,oraconcealed
spaceofabuilding.Onlyrigidorflexiblemetalventshall
beusedforexhausting.
Donotuseanexhausthoodwithamagneticlatch.
102 mm (4") heavy, metal exhaust vent
Onlya102mm(4")heavy,metalexhaustventandclamps
maybeused.
Donotuseplasticormetalfoilvent.
Rigid metal vent:
Recommendedforbestdryingperformanceandtoavoid
crushingandkinking.
Flexible metal vent: (Acceptableonlyifaccessibletoclean)
Mustbefullyextendedandsupportedinfinaldryer
location.
Removeexcesstoavoidsaggingandkinkingthatmayresult
inreducedairflowandpoorperformance.
Donotinstallinenclosedwalls,ceilings,orfloors.
Thetotallengthshouldnotexceed2.4m(7
Anexhausthoodshouldcaptheventtokeeprodentsand
insectsfromenteringthebuilding.
NOTE: Ifusinganexistingventsystem,cleanlintfromentire
lengthofthesystemandmakesureexhausthoodisnot
pluggedwithlint.Replaceplasticormetalfoilventswithrigid
metalorflexiblemetalvents.Review"VentSystemChart"and
ifnecessary,modifyexistingventsystemtoachievebestdrying
performance.

DRYER VENTING REQUIREMENTS

Elbows:
Clamps:
102 mm
(4")
ft.).
3
4
45°elbowsprovidebetterairflowthan90°elbows.
Good
Planinstallationtousethefewestnumberofelbowsand
turns.
Allowasmuchroomaspossiblewhenusingelbowsor
makingturns.Bendventgraduallytoavoidkinking.
Ventoutletislocatedatthecenterofthebottomdryer
back.
Theventcanberoutedup,down,left,right,behindthe
dryer,orstraightoutthebackofthedryer.
Useclampstosealalljoints.
Exhaustventmustnotbeconnectedorsecuredwithscrews
orotherfasteningdevicesthatextendintointeriorofduct
andcatchlint.Donotuseducttape.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
Housecleaning problems and health problems.
Better
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mde17mnbgwMde17csMde17mn

Table of Contents