Page 1
User Manual Blood Pressure Monitor TMB-995-GS-003 Arm Type Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-995-GS-003. Guangdong Transtek Medical Electronics Co., Ltd. Zone B, No.105 ,Dongli Road, Torch Development District, To use the monitor correctly and safely, please read the manual thoroughly.
CATALOGUE CATALOGUE Table of Contents INTRODUCTION........................2 General Description Indications for Use Contraindications Measurement Principle Safety Information LCD Display Signal Monitor Components List BEFORE YOU START......................9 The Choice of Power Supply Installing and Replacing the Batteries MEASUREMENT.........................10 Tie the Cuff Start the Measurement INFORMATION FOR USER....................13 Tips for measurement Maintenances...
Symbol for “SERIAL NUMBER” where facilities exist. Check with your local authority or retailer for recycling The Transtek Blood Pressure Monitor is a digital monitor intended for use in Symbol for “DIRECT CURRENT” advice” measuring blood pressure and heartbeat rate with arm circumference ranging Caution: These notes must Symbol for “MANUFACTURE...
Page 4
INTRODUCTION INTRODUCTION CAUTION CAUTION * This device is intended for adult use in homes only. * The ACCOMPANYING DOCUMENT shall disclose that the SPHYGMOMANOMETER was * The device is not suitable for use on neonatal patients, pregnant women,patients with clinically investigated according to the requirements of ISO 81060-2:2013. implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial * To verify the calibration of the AUTOMATED SPHYGMOMANOMETER, please contact the fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or...
* If you have any problems with this device, such as setting up, maintaining or using, please SYMBOL DESCRIPTION EXPLANATION contact the SERVICE PERSONNEL of Transtek. Don’t open or repair the device by yourself in the event of malfunctions. The device must only be serviced, repaired and opened by Systolic blood pressure High pressure result individuals at authorized sales/service centers.
Worn batteries are harmful to the environment. Do not dispose with daily garbage. Remove the old batteries from the device following your local recycling guidelines. 1. Blood Pressure Monitor 2. Cuff (22~42cm) 3. User manual (TMB-995-GS-003) (Type BF applied part) 4. 4*AA batteries...
MEASUREMENT MEASUREMENT Start the Measurement Tie the Cuff 1.When the monitor is off,press the START/STOP button to turn on the monitor, Remove all jewelry, such as watches and START bracelets from your left arm. and it will finish the whole measurement, STOP Note: If your doctor has diagnosed you with transmit the measurement data .
INFORMATION FOR USER MEASUREMENT Tips for Measurement 3.If the data is successfully transmitted, the “ ” will be shown, then the device will turn off. If the data transmission fails, the corresponding Measurements may be inaccurate if taken in the following error code is displayed, for example “...
DATA MANAGEMENT INFORMATION FOR USER ABOUT BLOOD PRESSURE Maintenance What are systolic pressure and diastolic pressure? In order to get the best performance, please follow the When ventricles contract and pump blood out Systolic Diastolic of the heart, the blood pressure reaches its instructions below.
ABOUT BLOOD PRESSURE TROUBLESHOOTING This section includes a list of error messages and frequently Why does my blood asked questions for problems you may encounter with your blood pressure fluctuate pressure monitor. If the products not operating as you think it should, check here before arranging for servicing.
This device complies with Part 15 of the FCC Rules. Operation is subject For more information about our products, please visit www.transtek.cn.you can get customer service, usual problems and customer download, transtek will serve you anytime. including interference that may cause undesired operation.
Warning:Portable RF communications equipment (including peripherals such as antenna cables and external essential performance - Collateral standard: Requirements for antennas) should be used no closer than 30 cm (12 inches) to any part of the equipment TMB-995-GS-003, medical electrical equipment and medical electrical systems used in including cables specified by the manufacturer.
Need help?
Do you have a question about the TMB-995-GS-003 and is the answer not in the manual?
Questions and answers