GRE PP051 Instruction Manual page 5

Hide thumbs Also See for PP051:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
B: 210 mm
C: 190 mm
D: 90 mm
E: 200 mm
F: 265 mm
G: 47,8 mm
H: 136,5 mm
I: 175 mm
J: 407,5 mm
EN- Self-priming swimming pool pump
SAFETY INSTRUCTIONS. READ CAREFULLY
• All electrical installations should comply with the following standard;
NF C15-100
NF EN 60-335-2-41
that refers "to the construction of electrical installations, both in indoor and outdoor
swimming pools", or the equivalent standard in force in each region or country.
• All filtering should follow the C 15-100 installation standard that stipulates that all
electrical apparatus located at less than 3.5
m. from the pool and freely accessible, should be supplied by a very low voltage of 12
V. All apparatus supplied with 220 V should be located at least 3.5 m. from the swim-
ming pool edge. Ask the manufacturer for permission to make any modifications in
one or more elements of the filtering system.
• The electrical installation should be performed by professional staff qualified in elec-
trical installations.
• The apparatus must not be on while the pool is being used.
• Do not operate the apparatus unless it is properly primed.
• NEVER touch the apparatus when it is operating if you are wet or have wet hands.
• When handling the pump, DISCONNECT the power supply.
• Make sure that the ground is dry before touching the electrical equipment.
• Do not install the apparatus where it could become wet, as it may cause electrocu-
tion.
• Do not allow children or adults to lean against or sit on the apparatus.
• If the supply flex of the apparatus is damaged, it should be replaced. Read the ins-
tructions carefully to replace it. If in doubt, contact the technical service.
This mode allows making a correct installation with optimal results of your swim-
ming pool pump. Carefully read this instruction manual.
Your new pump is a one-stage self-priming, centrifugal pump, designed for use with
a swimming-pool filtering system. It is designed to be used with clean water for
temperatures between 5 ºC and 35 ºC. It is manufactured from high quality materials
subject to strict hydraulic and electrical tests. A correct installation of this pump is as-
sured by following the instructions from this manual. We decline all responsibility for
damages caused by use different to that explained in this instruction manual.