Southbend FF-21-36 Hardware Manual

Deep fat fryer manual supplement for fryer filter system

Advertisement

IMPORTANT
m
southbe"d
~~n~~e~~~~
SERIAL #
A MIDDLEBY COMPANY
DATE PURCHASED
OWNER'S MANUAL
INSTALLATION
USER'S GUIDE
SERVICE
PARTS
DEEP FAT FRYER MANUAL SUPPLEMENT
for
FRYER FILTER SYSTEM
MODEL FF-21-36, FF-21-42
These instructions should be read thoroughly before attempting installation. Set up,
installation and Performance Check should be performed by a qualified service
technician. The Manufacturer, Southbend (1100 Old Honeycutt Rd., Fuquay-Varina, North
Carolina 27526), informs you that unless the installation instructions for the above
described Southbend product are followed and performed by a qualified service
technician, (a person experienced in and knowledgeable concerning the installation of
commercial gas and/or electrical cooking equipment) then the terms and conditions of the
Manufacturer's Limited Warranty will be rendered void and no warranty of any kind shall
atwb.
If the equipment has been changed, altered, modified or repaired by other than a
qualified service technician during or after the 12-month limited warranty period, then
the manufacturer shall not be liable for any incidental or consequential damages to any
person or to any property which may result from the use of the equipment thereafter.
Some States do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion thereto may not apply to you.
In the event you have any questions concerning the installation, use, care, or service of
the product, write Customer Service Department, Southbend, 1100 Old Honeycutt Rd.,
Fuquay-Varina, North Carolina 27526.
FRYER FILTER SYSTEM
DEEP FAT FRYER
(Manual Section SR)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FF-21-36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Southbend FF-21-36

  • Page 1 The Manufacturer, Southbend (1100 Old Honeycutt Rd., Fuquay-Varina, North Carolina 27526), informs you that unless the installation instructions for the above described Southbend product are followed and performed by a qualified service technician, (a person experienced in and knowledgeable concerning the installation of commercial gas and/or electrical cooking equipment) then the terms and conditions of the Manufacturer’s Limited Warranty will be rendered void and no warranty of any kind shall...
  • Page 2 With proper care and field maintenance, you will experience years of reliable, trouble-free operation from your Southbend equipment. To get the best results, it’s important that you read this manual carefully.
  • Page 3: Installation

    FRYER FILTER SYSTEM FRYER FILTER FF=?l-36 FRONT VIEW DIMENSIONS: UTILITY INFORMATION l/3 HF’ - 115 OR 230 VOLT AMPS - 115 VOLT - 6.5 230 VOLT - 2.6 INSTALLATION GENERAL: THE UNIT WHEN INSTALLED MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE ANSI 2223.1.1984.
  • Page 4 THESE PROCEDURES MUST BE FOLLOWED WARRANTY WILL BE VOIDED. LEGS OR OPTIONAL CASTERS: 1. A set of legs or casters are packed in the unit. A threaded receptacle is fastened to the base frame at each comer. Each leg or caster has a similar mating thread. 2.
  • Page 5: Operation

    OPERATION FRYER FILTER OPERATION This section describes the cleaning process for your fryer know as the “Boil -Out”. A “Boil-Out” should be performed on new equipment prior to actual cooking and every time shortening is removed from the fryer for cleaning of the fry-kettle and replacement by fresh shortening.
  • Page 6 19. Slide the filter pan forward and carefully remove it for cleaning. Note - We recommend that you use Southbend Cleanser or an equivalent cleanser such Ajax or Comet to clean the filter pan. Avoid liquid dishwashing detergents as they may leave residues which reduce shortening life.
  • Page 7 Remove the Hold-Down frame from the filter pan and place it in the sink for cleaning. Note - Use only Southbend Boil or a cleanser such as Ajax or Comet to clean the Hold-Down frame as well as the other interior surfaces and components of the filter pan.
  • Page 8 Drain Pipe Nipple Filter Pan Hold-Down Rack with Latchw Remove the crumb and breading residue from the small ledge which surrounds the Hold-Down rack that secures the filter paper in place. Remove crumbs and breading residue from the top sheet of filter paper with the metal crumb shovel supplied with the fryer.
  • Page 9 Failure to insure that the Thermostat is in the “Off” position during procedure may result in equipment damage and/or personal iqjury. Stir 8 ounces of Southbend filter powder in the hot oil. The filter powder helps extend shortening life by removing impurities.
  • Page 10: Maintenance

    WARNING; HOT FRYING COMPOUND CONTACT WITH HOT FRYING COMPOUND WILL CAUSE SEVER BURNS. ALWAYS USE CAUTION, FRYING COMPOUND AT 200°F IS MORE DANGEROUS THAN BOILING WATER MAINTENANCE CONSULT DEEP FAT FRYER OWNERS hJANUAL, - PART # 11611609 FOR CLEANING INSTRUCTIONS. FRYER FILTER SYSTEM PAGE 6 USER’S GUIDE...
  • Page 11 ’ ADJUSTMENTS ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED TECHNICIAN WHO IS EXPERIENCED OPERATION OF COMMERCIAL YOUR CONFIDENCE, CONTACT RELIABLE SERVICE, DEPENDABLE GENUINE FACTORY PARTS. TROUBLE SHOOTING DESCRIPTION 1. Quick Disconnect For Filter Pan #1174293 2. Filter Pan #1174289 3. Filter Pan Hold-Down Bracket and Latches #1174288 4.
  • Page 12 DESCRIPTION 6. Quick Disconnect for Oil Discharge Wand #1174293 OIL FIITRATION SYSTEM INOPERATIVE; 1. If switch is in the “On” Position, use a multimeter to verify that the pump switch is functioning properly. If switch is operative, refer to wiring diagram and locate the filter pump and motor assembly and use a multimeter to check for proper voltage at the pump motor.
  • Page 13: Filter System

    When ordering, please supply the Model Number, Serial Number, Part Number, Description, plus Finish, Qpe of Gas and Electrical Characteristics, as applicable. For parts not listed consult a Southbend Authorized Parts Depot or Southbend Authorized Service Agency. If necessary, please consult Southbend Escan Parts Department for assistance.
  • Page 14 FIG. 2 UNIT SHOW FIG. 3 FRYER FILTER S PARTS...
  • Page 15 DEEP FAT FRYER MANUAL SUPPLEMENT FOR FRYER FILTER SYSTEM A product with the Southbend name Incorporates the best In durability and low maintenance. We all recognize however, that replacement parts and occasional professional service may be necessary to extend the useful life of this unit. When mvbe la needed, contact a Southbend Authorized Service Agency, or your dealer.

This manual is also suitable for:

Ff-21-42

Table of Contents