MECHANICAL DATA
DC connector type
Dimensions (H × W × D)
Weight (with mounting plate)
Cooling
Enclosure
IP rating
Maximum altitude
Calorific value
STANDARDS
Grid compliance (with IQ Relay)
Safety
EMC
Product labeling
Advanced grid functions
Microinverter communication
At STC within MPP range.
(2)
Some of these functions require IQ Gateway Metered with current transformers and/or IQ Relay installed.
(3)
31
IQ8P Microinverter Installation and Operation Manual
3
© 2023 Enphase Energy Inc. All rights reserved.
IQ8P-72-2-INT
Supplied with Stäubli MC4 adapter
265 mm (10.4") × 200 mm (7.9") × 35 mm (1.4") (without
mounting brackets)
1.6 kg (3.5 lbs)
Natural convection – no fans
Class II double-insulated, corrosion-resistant polymeric
enclosure
Outdoor - IP67
< 2,600 m
59.25 MJ/unit
IQ8P-72-2-INT
EN 50549-1
EN IEC 62109-1, EN IEC 62109-2
EN IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-3,
EN IEC 50065-1, 50065-2-1,
EN55011
Power export limiting (PEL), phase imbalance
management (PIM), loss of phase detection
(LOP), power factor control Q (U), cos (phi) (P)
Power line communication (PLC) 110 – 120 kHz (Class
B), narrow band 200 Hz
2
CE
September 2023