Set Range Optimization
This command applies an adjustment factor to the over-the-air timing of remotes to
compensate for the effects of propagation delay at long ranges. The default setting of
00H is suitable for ranges of 0 to 0.8 miles (1287 m), with optimal performance at 0.1
miles (162m). Each increment of this parameter adds 0.1 miles (162 m) to the
working range. Thus the optimal and max ranges are determined by:
optimal = 0.1mi + 0.1mi x dx = 0.17km + 0.17km x dx
max = 0.8mi + 0.1mi x dx = 1.33km = 0.17km x dx
The following table presents various values of dx and the associated optimal and max
ranges.
dx
setting
00H
01H
04H
06H
09H
13H
31H
45H
64H
C8H
FAH
Optimal 'dx' setting for various distances.
Copyright © Murata Manufacturing Co., Ltd. All Rights Reserved. 2004
HN-210/210X 01/13/17
range:
optimal
min
0mi/0km
0.1mi/0.2km
0mi/0km
0.2mi/0.3km
0mi/0km
0.5mi/0.8km
0.1mi/0.2km
0.7mi/1.2km
0.4mi/0.7km
1.0mi/1.6km
1.4mi/2.3km
2.0mi/3.3km
4.4mi/7.3km
5.0mi/8.3km
6.4mi/10.7km
7.0mi/11.7km
9.4mi/15.7km
10.0mi/16.7km
19.4mi/32.3km
20.0mi/33.3km
24.4mi/40.7km
25.0mi/41.7km
42 of 58
Downloaded From
max
0.8mi/1.3km
0.9mi/1.5km
1.2 mi/2.0km
1.4mi/2.3km
1.8 mi/3.0km
2.8mi/4.7km
5.8 mi/9.7km
7.8mi/13.0km
10.8mi/18.0km
20.8mi/34.7km
25.8mi/43.0km
Oneyac.com
HN210
www.murata.com