Status Commands - Murata Hn-210 Manual

Outdoor base remote
Table of Contents

Advertisement

Status Commands

These commands deal with general interface aspects of the operation of the HopNet.
Command
zb[?|0|1]
zc[?|0..2]
zh?
zm?
zl?
zp[?|0-5]
base only)
zq[?|0|1]
remote only)
z>
Banner Display Disable
Enables or disables display of the banner string and revision code automatically at
power-up. May be disabled to avoid being mistaken for data by the host.
Set Escape Sequence Mode
Enables or disables the ability to use the in-data-stream escape sequence method of
accessing Control Mode by transmitting the string ":wit2410". When this mode is set
to 1, the escape sequence only works immediately after reset (this is the default).
When set to 2, the escape sequence may be used at any time in the data stream when
preceded by a pause of 20 ms. For backwards compatibility with the WIT2400, the
string ":wit2400" is also accepted for entering Control Mode. Note that the escape
sequence must be interpreted as data by the radio until the last character is received,
and as such will be transmitted to a receiving radio station.
Copyright © Murata Manufacturing Co., Ltd. All Rights Reserved. 2004
HN-210/210X 01/13/17
Description
Banner Display Disable
0 = disabled
1 = enabled (default)
Set Escape Sequence Mode
0 = disabled
1 = once after reset (default)
2 = unlimited times
Read factory serial number high byte.
Read factory serial number middle byte.
Read factory serial number low byte.
Set the duty cycle at which the modem will wake up to send and
receive data. Duty cycle equals 1/2
command equals N.
Low Power Acquisition Mode Enable
0 = Disabled (default)
1 = Enabled
Exit Modem Control Mode
46 of 58