Wiring Instructions For Inter-Unit Connections - Sanyo 18KLS72 Installation Instructions Manual

Indoor/outdoor unit inverter split system air conditioner
Hide thumbs Also See for 18KLS72:
Table of Contents

Advertisement

3-8. Wiring Instructions for Inter-unit Connections

(1) Insert the inter-unit wiring (according to local codes)
into the through-the-wall PVC pipe. Run the wiring
toward the indoor side allowing approx. 10" (25 cm)
to extend from the wall face. (Fig. 24)
(2) Grasp both ends of the air intake grille, and remove
it by opening towards the front and pulling towards
you.
(3) Remove the screw on the right side cover plate and
open the cover. (Fig. 25)
(4) Route the inter-unit wiring from the back of the
indoor unit and pull it toward the front for connec-
tion. (Fig. 26a, 26b)
(5) Connect the inter-unit wiring to the corresponding
terminals on the terminal plate (Fig. 26a, 26b) while
referring to the wiring diagram.
(6) Be sure to secure the wiring with the provided
clamp.
NOTE
When closing the air intake grille, press the bottom right
and left corners and center. (Fig. 27)
Please refer to "How to replace the grille" on page 11 for
installing the air intake grille.
Fig. 27
Rear
panel
Wiring
Earth
plate
Top of conduit
connector
14
Wall
Plastic
cover
10"
(25 cm)
Fig. 24
Cover
Fig. 25
Terminal
plate
Fig. 26a
Inter-unit
wiring
Lock nut
Fig. 26b

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents