Mount and tighten screw
Guideline
Screw plug, water
pump drain hole
600616-10
–
Stand the motorcycle on a level surface using the side stand.
–
Refill with coolant.
Coolant
–
Completely fill the radiator with coolant.
–
Mount radiator cap
S03317-10
–
Remove compensating tank cover
–
Add coolant to the top marking.
–
Mount the cover of the compensating tank.
Danger
Danger of poisoning Exhaust gases are toxic and inhaling
them may result in unconsciousness and death.
–
Always make sure there is sufficient ventilation when
running the engine.
V02746-12
–
Use effective exhaust extraction when starting or run-
ning the engine in an enclosed space.
–
Start the engine and allow it to warm up.
–
Stop the engine and allow it to cool down.
Finishing work
–
Check the coolant level. (
–
Install the engine guard. (
COOLING SYSTEM 15
1
with a new seal ring.
M10x1
15 Nm (11.1 lbf ft)
1.20 l (1.27 qt.)
Coolant (
2
.
3
.
p. 99)
p. 65)
p. 127)
103