Download Print this page

DeltaTRAK FlashLink 22367 Installation Instructions Manual

3g-2t in-transit logger

Advertisement

Quick Links

User Instructions
Model 22367
3G-2T In-Transit Logger
Installation Instructions

Advertisement

loading
Need help?

Need help?

Do you have a question about the FlashLink 22367 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DeltaTRAK FlashLink 22367

  • Page 1 User Instructions Model 22367 3G-2T In-Transit Logger Installation Instructions...
  • Page 2 When ready to start loading the container, first ensure the logger is disconnected from the external sensor cable before proceeding. Disconnect cable from the logger...
  • Page 3 Activate the FlashLink RTL Logger with the cable disconnected: • Press and hold the green START button until the STATUS LED flashes 5 times, then release the button • If the LEDs flash red-blue-red-blue when START button is released, this indicates the logger did NOT activate •...
  • Page 4 Remove the peel away barcode label from the sleeve and place it on your copy of the shipping paperwork. This has the trip number which is needed for reference and traceability Load the first two pallets in the back of the container Take the sensor cable and affix the probe tip to one of the first pallets.
  • Page 5 Run the sensor cable through the T-channel on the floor of the container towards the doors. Make sure it is completely inside the T-channel to keep it from being damaged while loading the additional pallets. The side channel should have top covers, which will help keep the cable from popping out of the T-channel If the temperature needs to be tracked in the middle of the container, the probe can be installed between cargo boxes at...
  • Page 6 Leave the extra cable length inside the safety of the T-channel, (pictured in step 6) or you may place it under the container (pictured below) to avoid damage while loading the remaining pallets. Load all the remaining pallets Take the sensor cable from the T-channel and bring it up the front of the last pallet, under the straps and skimmers to the top carton.
  • Page 7 Connect the sensor cable to the RTL logger, pressing the stereo jack firmly together until her it ‘CLICK’ If it is not completely connected, the external sensor will not register temperature. Wrap tape around the stereo jack for extra security to avoid accidental disconnection during transit.
  • Page 9 DeltaTrak Corporate P.O. Box 398 Pleasanton CA 94566 (925) 249-2250 (800) 962-6776 www.deltatrak.com DTI Mexico International Guadalajara, Mexico +52-33-3188-3161 / 36712190 www.deltatrakmexico.com DTI South America SA Santiago, Chile +562 2758 2866  +569 7477 1061 www.deltatraksouthamerica.com DTI China Limited Shenzhen China...