Apollo Healthcare Technologies Limited APH059 User Manual

Apollo Healthcare Technologies Limited APH059 User Manual

Dynamic replacement mattress

Advertisement

Quick Links

A World of Healthcare Solutions
DECLARATION OF CONFORMITY
The Company
Apollo Healthcare Technologies Ltd
Holme Street
Liversedge
West Yorkshire
WF15 6JF
Declares that the articles which it sells, called ............................
and related accessories, are classified as Class I non-invasive
Medical Devices according to Medical Directive 93/42/EEC and to
national law no. 46/97 and comply with the European Directive on
CE marking; in addition
• they are not measuring instruments;
• they are not intended for clinical investigations;
• they are sold in non-sterile packaging;
The above mentioned devices meet with the
essential requirements and provisions of
Directive 93/42/EEC.
Apollo Healthcare Technologies Ltd endeavour to provide the
exact specification as printed. Apollo Healthcare Technologies Ltd
reserve the right to change specification without prior notice.
Apollo Healthcare Technologies Limited, Holme Street, Liversedge, West Yorkshire WF15 6JF
Tel: +44 (0) 1924 400900 Fax: +44 (0) 1924 412466 Email: sales@apollo-ht.co.uk www.apollo-ht.co.uk
Apollo Pro
Dynamic Replacement Mattress
USER MANUAL
Product Code - APH059

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the APH059 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Apollo Healthcare Technologies Limited APH059

  • Page 1 Apollo Healthcare Technologies Ltd reserve the right to change specification without prior notice. Apollo Healthcare Technologies Limited, Holme Street, Liversedge, West Yorkshire WF15 6JF Tel: +44 (0) 1924 400900 Fax: +44 (0) 1924 412466 Email: sales@apollo-ht.co.uk www.apollo-ht.co.uk...
  • Page 2: Table Of Contents

    STATEMENTS & SYMBOLS TABLE OF CONTENTS Note, caution, warning & danger statements STATEMENTS & SYMBOLS ..................... NOTE ........................INTRODUCTION ..5 Indicates some tips or some information users should be aware of........................ PACKAGE CONTENT ..5 CAUTION ......................PRODUCT FUNCTIONS ..
  • Page 3: Introduction

    Pump INTRODUCTION Make sure the type of pump is identical to which you purchased. Functionalities vary from model to model. This manual should be used for the initial set up of the system and for reference purposes. General The Apollo Pro is a high quality and affordable air support surface suitable for medium and high-risk pressure ulcer treatment.
  • Page 4 PRODUCT FUNCTIONS STATIC/ALTERNATING switch (6) Press the STATIC/ALTERNATING switch to switch the air mattress to STATIC mode or ALTERNATING mode. The amber STATIC indicator (or the green ALTERNATING Pump indicator) lights up to indicate the correspondent operation mode. POWER switch CYCLE TIME switch (7) The CYCLE TIME switch can be used to select the appropriate cycle time of the inflation MUTE switch...
  • Page 5: Installation

    OPERATION INSTALLATION General Step 1 Place the mattress flatly on the bed frame. The inflation tube should be towards the foot end so that it can be connected to the This product is designed to provide maximum comfort to home care patients. Make sure that inflation nozzles on the pump.
  • Page 6 Pressure adjustment Turn the power ON The pressure of the mattress can be set by pressing the PRESSURE SELECTION keys. A BEEP sound will begin the operation. The indicator (green) of the power switch will light up, There are totally 8 different pressure levels selectable ranging from 20 to 60 mmHg. and the pump starts to pump air into the mattress.
  • Page 7: Cpr Function

    Low pressure warning To silence the alarm When abnormal pressure occurs, the Low Pressure indicator will come on. The audible alarm will be activated to bring attention to a low pressure condition. If the pressure drops below the pre-defined level, the LOW PRESSURE indicator will light up Check if the connections are secure and correctly installed according to the relevant accompanied with a BEEP alarm tone.
  • Page 8: Cleaning

    HANDLING AND STORAGE CLEANING Lay the mattress out flat and upside down. In this section, we describe the procedures to clean and decontaminate the pump. It is Roll from the foot end towards the head end; the foot-end strap can then be s t r e t c h e d important to follow these procedures before using the system on patients.
  • Page 9: Troubleshooting

    SPECIFICATIONS TROUBLESHOOTING System Problems Solutions Item Specifications 1. Check if the plug is inserted firmly into the outlet. The pump doesn’t work 2. Turn on the power switch again. Classification Class II; IP21; AP/APG NO; Type BF If the power indicator is ON and the pump still doesn’t w o r k , contact your local dealer immediately.
  • Page 10 Table 2 –MANUFACTURER’S declaration – electromagnetic Table 1–MANUFACTURER’S declaration – ELECTROMAGNETIC IMMUNITY –for all ME EQUIPMENT and ME SYSTEMS EMISSIONS – for all ME EQUIPMENT and ME SYSTEMS GUIDANCE AND MANUFACTURER’S DECLARATION – GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC IMMUNITY ELECTROMAGNETIC EMISSIONS The Air pump is intended for use in the electromagnetic environment specified below.
  • Page 11 T T able 3 – G G u u i i da a n n c c e a a n n d MAN N U U F F A A C C T T U U R R E E R R ’S d d e e c c l l a a r r a a t t t i i o o n – e e l l e e c c t t ro o m m a a g g n n e e t t ic IMMU U N N I I TY –f f or ME EQUI I PMENT and ME SYSTEMS t t h h at are no o t L L I I F F E E -S S U U P P P P O O R R T T ING NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
  • Page 12 NOTES Tabl l e e 4 – R R ec c o o mm m en n d d ed s s s e e e pa a r r a a t t i i on d d i i s s t t a a nc c e e s s b b e e t t w w ee e n n p p o o rtab b l l e an n d d mo o b b i i l l e e RF c c o o mmunic c a a tions equipment and the ME E E QUIP P ME E NT or ME S S Y Y S S TE E M –...

Table of Contents