Table Of Contents - flowair ELIS B W 100 2R Technical Documentation Operation Manual

Hide thumbs Also See for ELIS B W 100 2R:
Table of Contents

Advertisement

SPIS TREŚCI
1. INFORMACJE OGÓLNE ............................................................................ 3
2. DANE TECHNICZNE .................................................................................. 4
2.1. BUDOWA .......................................................................................... 4
2.2. WYMIARY ......................................................................................... 5
2.3. POZIOM CIŚNIENIA AKUSTYCZNEGO ................................................ 5
2.4. WYDAJNOŚĆ ..................................................................................... 5
2.5. PRĘDKOŚCI PRZEPŁYWU POWIETRZA ............................................... 6
3. TABELE MOCY GRZEWCZYCH .................................................................. 6
3.1. KURTYNA ELIS B-W-100 .................................................................... 6
3.2. KURTYNA ELIS B-W-150 .................................................................... 7
3.3. KURTYNA ELIS B-W-200 .................................................................... 7
3.4. KURTYNA ELIS
B-2R-100
3.5. KURTYNA ELIS
B-2R-150
3.6. KURTYNA ELIS
B-2R-200
4. MONTAŻ W ZABUDOWIE SUFITOWEJ ..................................................... 9
5. AUTOMATYKA ....................................................................................... 11
5.1 ELEMENTY AUTOMATYKI ............................................................... 11
5.2 PODŁĄCZENIE STEROWANIA ORAZ ZASILANIA ............................... 13
5.3 UKŁAD STEROWANIA DRV ELiS ...................................................... 14
5.3.5 STEROWANIE - ŁĄCZENIE MASTER-SLAVE ............................ 19
5.3.6 STEROWANIE - PODŁĄCZENIE BMS ..................................... 20
5.3.7 STEROWANIE - ŁĄCZENIE DRV ............................................. 20
5.3.8 STEROWANIE - USTAWIENIE ADRESU .................................. 21
6. MONTAŻ CZUJNIKA DRZWIOWEGO ...................................................... 22
7. PODŁĄCZENIE INSTALACJI ELEKTRYCZNEJ ............................................. 23
8. PODŁĄCZENIE INSTALACJI WODNEJ ...................................................... 23
9. EKSPLOATACJA ...................................................................................... 23
10. CZYSZCZENIE I KONSERWACJA .............................................................. 24
11. REGULACJA KRATKI WYLOTOWEJ ......................................................... 24
12. SERWIS I GWARANCJA .......................................................................... 25
Dziękujemy Państwu za zakup kurtyny powietrznej ELIS.
Niniejsza instrukcja obsługi została wydana przez firmę FLOWAIR GŁOGOWSKI
I BRZEZIŃSKI SP.J. Producent zastrzega sobie prawo do wprowadzenia poprawek
i zmian w instrukcji obsługi w dowolnym czasie i bez powiadomienia, a także zmian
w urządzeniu nie wpływających na jego działanie.
Instrukcja ta jest integralną częścią urządzenia i powinna znajdować się w jego pobliżu.
Aby zapewnić prawidłową obsługę urządzenia należy dokładnie zapoznać się z niniejszą
instrukcją i zachować ją na przyszłość.
Urządzenia mogą być instalowane i eksploatowane wyłącznie w warunkach do jakich
zostały przystosowane. Kurtyny przeznaczone są do pracy wewnątrz pomieszczeń
o maksymalnym zapyleniu powietrza 0,3 g/m
wykonane z aluminium, tworzywa sztucznego, miedzi oraz stali cynkowej i nie mogą być
stosowane w środowisku mogącym powodować ich korozję.
Każde inne zastosowanie, niezgodne z niniejszą instrukcją może prowadzić do
uszkodzenia urządzenia bądź wystąpienia groźnych w skutkach wypadków. Należy
dołożyć wszelkich starań w celu wyeliminowania możliwości niewłaściwego stosowania
urządzenia. Należy ograniczyć dostęp do urządzenia osobom nieupoważnionym oraz
przeszkolić personel obsługujący. Producent nie bierze żadnej odpowiedzialności za
zniszczenia będące wynikiem błędów instalacji, złej eksploatacji, lub będących wynikiem
nie zapoznania się z wytycznymi instrukcji producenta
ZALECENIA I WYMAGANE ŚRODKI OSTROŻNOŚCI
Przed wykonaniem jakichkolwiek prac przy urządzeniu należy zapoznać się
z niniejszą instrukcją obsługi.
Urządzenie może być instalowane wyłącznie przez wykwalifikowany personel,
posiadający odpowiednie uprawnienia i kwalifikacje.
Podciśnienie w budynku obniża sprawność kurtyny powietrznej
Podczas wykonywania prac przy urządzeniu, należy pamiętać o własnym
bezpieczeństwie.
Przy montażu, podłączeniu elektrycznym, podłączeniu do medium grzewczego,
uruchamianiu,
naprawach
oraz
przestrzegać powszechnie uznawanych przepisów i norm bezpieczeństwa.
www.flowair.com |2
................................................................... 8
................................................................... 8
................................................................... 9
. Urządzenia posiadają elementy
3
konserwacji
aparatów
grzewczych

TABLE OF CONTENTS

1. GENERAL INFORMATION ....................................................................... 3
2. TECHNICAL DATA .................................................................................... 4
2.1. CONSTRUCTION ............................................................................... 4
2.2. DIMENSIONS .................................................................................... 5
2.3. ACOUSTIC PRESSURE LEVEL ............................................................. 5
2.4. AIR VOLUME .................................................................................... 5
2.5. AIR FLOW SPEED .............................................................................. 6
3. HEAT OUTPUT DATA ............................................................................... 6
3.1. ELIS B-W-100 .................................................................................... 6
3.2. ELIS B-W-150 .................................................................................... 7
3.3. ELIS B-W-200 .................................................................................... 7
3.4. KURTYNA ELIS
3.5. KURTYNA ELIS
3.6. KURTYNA ELIS
4. INSTALLATION ......................................................................................... 9
5. CONTROL SYSTEMS ............................................................................... 11
5.1. CONTROL ELEMENTS ...................................................................... 11
5.2. CONNECTING GUIDE ...................................................................... 13
5.3. DRV ELIS CONTROL SYSTEM .......................................................... 14
5.3.4. REGULATION T-BOX - WIRING DIAGRAMS .......................... 18
5.3.6. CONTROL SYSTEM - BMS CONNECTION ............................ 20
5.3.7 CONTROL SYSTEM - DRV CHAINING ................................... 20
6.
DOOR CONTACT INSTALLATION ........................................................... 22
8. GUIDELINES FOR CONNECTION WITH PIPELINE .................................... 23
9. OPERATION ........................................................................................... 23
10. CLEANING AND CONSERVATION ........................................................... 24
11. OUTLET GRILL ADJUSTING..................................................................... 24
12. SERVICE ................................................................................................. 25
Thank you for purchasing the ELiS curtain.
This operation manual has been issued by the FLOWAIR GŁOGOWSKI I BRZEZIŃSKI
SP.J. company. The manufacturer reserves the right to make revisions and changes in
the operation manual at any time and without notice, and also to make changes in the
device without influencing its operation
This manual is an integral part of the device and it must be delivered to the user together
with the device. In order to ensure correct operation of the equipment, get thoroughly
acquainted with this manual and keep it for the future.
The devices may only be installed and operated in conditions for which they have been
designed. Any other application, inconsistent with this manual, may lead to the
occurrence of accidents with dangerous consequences. Every effort must be made in
order to eliminate the possibility of improper use of the device. Access of unauthorized
persons to the device should be restricted, and the operating personnel should be
trained. The manufacturer bears no responsibility for damage resulting from incorrect
installation, improper operating, or not getting acquainted with the guidelines of the
manufacturer manual.
RECOMMENDATIONS AND REQUIRED SAFETY MEASURES
Get acquainted with this operation manual before performing any works at the
device.
The device may only be installed by qualified personnel with adequate
authorisations and skills.
In the building where ventilation causes underpressure, air cutrain may have limited
efficiency
When performing works at the device, remember about your own safety.
During installation, electrical connection, connection to the heating medium, start-
należy
up, repairs and maintenance of air curtains, observe the commonly recognized
safety standards and regulations.
................................................................... 8
B-2R-100
................................................................... 8
B-2R-150
................................................................... 9
B-2R-200

Advertisement

Table of Contents
loading

Table of Contents