AUTOHELM NMEA BRIDGE User Manual

Raymarine nmea bridge audio: user guide

Advertisement

Distributed by
Any reference to Raytheon or
RTN in this manual should be
interpreted as Raymarine.
The names Raytheon and RTN
are owned by the
Raytheon Company.

Advertisement

Table of Contents
loading

Summary of Contents for AUTOHELM NMEA BRIDGE

  • Page 1 Distributed by Any reference to Raytheon or RTN in this manual should be interpreted as Raymarine. The names Raytheon and RTN are owned by the Raytheon Company.
  • Page 2 NMEA Bridge Operation and Installation Handbook NMEA BRIDGE Operation and Installation...
  • Page 3: Table Of Contents

    NMEA Bridge Operation and Installation Handbook Contents Chapter 1: Introduction ... 3 Chapter 2: Mounting ... 4 Chapter 3: Operation/Wiring ... 6 3.1 NMEA Output ... 6 3.2 NMEA Input ... 9 3.3 Main Alarm ... 12 3.4 Connecting to a Personal Computer ... 14...
  • Page 4 NMEA Bridge Operation and Installation Handbook...
  • Page 5: Nmea Bridge Operation And Installation Handbook

    Chapter 1: Introduction SeaTalk is the language used by all Autohelm products to share information. This is unique to Autohelm. The NMEA Bridge, by providing conversion between SeaTalk and NMEA 0183 data format, allows operation with other manufacturer's equipment .
  • Page 6: Chapter 2: Mounting

    • accessible for cabling • reasonably well protected from physical damage. Once a suitable location has been found, thoroughly clean the surface with an alcohol based cleaner. Remove the protective backing from the NMEA Bridge and firmly press onto the mounting surface.
  • Page 7 NMEA Bridge Operation and Installation Handbook Alternatively, the NMEA Bridge may be attached using the 2 self tapping screws provided. Remove the top of the Bridge by squeezing the lid at each end and pull away from the base. Route all the necessary cables into the Bridge.
  • Page 8: Chapter 3: Operation/Wiring

    NMEA Bridge Operation and Installation Handbook Chapter 3: Operation/Wiring 3.1 NMEA Output Providing you have the appropriate SeaTalk instrumentation, the data listed below is transmitted in NMEA 0183 format for use with non-SeaTalk equipment. Note: NMEA is also output in response to NMEA input.
  • Page 9 NMEA Bridge Operation and Installation Handbook Data GPS Satellite Azimuth GPS Satellite Elevation GPS Satellite PR Number GPS Satellite SNR GPS Differential Station ID GPS Differential AGE GPS Number of Satellites GPS Antenna Height GPS Quality Indicator Heading (Magnetic or True) Latitude &...
  • Page 10 NMEA Bridge Operation and Installation Handbook Cabling The NMEA Bridge should be connected to SeaTalk and the other manufacturer's equipment as follows: (v+) Yellow (Data) Screen (0v) Red (v+) Power Screen (0v)
  • Page 11: Nmea Input

    NMEA Bridge Operation and Installation Handbook 3.2 NMEA Input The NMEA Bridge can also be used to convert NMEA 0183 data to SeaTalk. NMEA 0183 data is also re-transmitted on NMEA "OUT" in response to NMEA "IN". This allows non-SeaTalk equipment to be connected directly to the SeaTalk bus.
  • Page 12 NMEA Bridge Operation and Installation Handbook Data GPS Number of Satellites GPS Antenna Height GPS Quality Indicator Heading (Magnetic or True) Latitude & Longitude MOB (Cancel) Route Speed Over Ground Speed Through water Temperature, Water Time True Wind Angle Variation RMA, HVD Waypoint Destination No.
  • Page 13 NMEA Bridge Operation and Installation Handbook Waypoint Capture Waypoints, last one & next 4 PNATA Cabling (ST1,2,3000 autopilots)
  • Page 14: Main Alarm

    NMEA Bridge Operation and Installation Handbook Yellow (Data) Screen (0v) Screen (0v) Red (12V) 5A Fuse 3.3 Main Alarm The NMEA Bridge can be used to drive the Autohelm Main Alarm (Cat No Z035). This alarm will sound as soon as one of...
  • Page 15 NMEA Bridge Operation and Installation Handbook the following alarms is present on the SeaTalk bus: • Deep Depth • Shallow Depth • Autopilot off course • Watch alarm* • Wind shift* • Low battery* • Large Cross Track Error* • No NMEA data* •...
  • Page 16: Connecting To A Personal Computer

    The Main Alarm should be wired to the NMEA Bridge as follows: 3.4 Connecting a Personal Computer The NMEA Bridge can be used to send or receive NMEA data to or from a personal computer via the "RS232 OUT and NMEA...
  • Page 17 NMEA Bridge Operation and Installation Handbook IN" terminals, as shown in the following illustrations. Screen (v+) (0v) Power Yellow (Data) Screen (0v) Red (v+)
  • Page 18 NMEA Bridge Operation and Installation Handbook PC Serial Port Connections to NMEA The following diagram shows the pin connections for 25 and 9 pin PC serial ports to NMEA. DB25 25 PIN SERIAL CONNECTOR Transmit Receive Ground DB9 9 PIN...
  • Page 19: Chapter 4: Fault Finding

    NMEA Bridge Operation and Installation Handbook Chapter 4: Fault Finding All Autohelm products are comprehensively tested procedure prior to packing and shipment. In the unlikely event that a fault does occur, the following check list should help cure the problem.