Page 3
English (GB) Service instructions ............... . 4...
English (GB) Service instructions Original service instructions 2. Safety Table of contents WARNING Mixer installation in pits must be carried out by specially Symbols used in this document ....4 trained persons.
4. Storing and handling the product 4.1 Handling the product The mixer weighs between 36 and 65 kg without accessories. It is therefore very important to use the correct lifting equipment. The mixer weight is stated on the nameplate. Make sure that all lifting equipment is rated for the purpose.
ISO VG 68 WARNING [litre] Before starting any service work, remove the fuses or switch off the power supply. Make sure that the power SMD.09.21.1478 supply cannot be accidentally switched on. SMD.11.25.1470 All rotating parts must have stopped moving. 0.13 SMD.14.25.1460...
Explosion-proof versions must be serviced and repaired by shaft end. Grundfos or by a service partner appointed by Grundfos. 8. Remove the motor flange (1020) from the shaft using a puller. Spare parts Replace defective parts.
11.3.5 Moisture switch 3. Fit the screws. See section Torques and lubricants. 1. Disconnect the wires of the moisture switch (1080). 4. Fit and tighten the clamping ring (1138), if not fitted. 2. Remove the screw (1082). Related information 3. Remove the moisture switch (1080). 7. Torques and lubricants 11.4.3 Leakage sensor 1.
Page 10
6. Fit the screws. See section Torques and lubricants. 7. Lubricate the lip seal (1104) with Loctite MR 5923 and knock it home on the propeller (1103) using the bearing fitting tool kit (A). 8. Fit the key (1105) and the propeller (1103) onto the shaft. 9.
12. Testing the AL05 Ex leakage sensor WARNING If the sensor has been or is to be incorporated in an explosion-proof product, you must not carry out the tests described below. The intrinsically safe sensor (EN 60079-11) loses the explosions-proof aspect if it is connected to non-intrinsically safe devices.