COOPER LIGHTING - METALUX
WB SERIES
4 ' o r 8 ' S u r f a c e
2 o r 4 L a m p s
S U R F A C E W I D E
W R A PA R O U N D
• Equipped with energy
saving ballast/complies
with federal energy
efficiency standards
• Low profile
• Low brightness/extruded
acrylic refractor
• Injection molded end caps
• Die formed channel
• Baked white enamel finish
• Lift and shift refractor for
ease of re-lamping
• Surface or stem mounting,
single or continuous row
• Also available in tandem 8'
lengths
• UL/CUL Listed. Suitable for
damp locations.
420
COOPER LIGHTING
D E S C R I P T I O N
The WB Series is a premium
wraparound luminaire featuring
wide body construction and
energy efficient performance.
The luminaire's characteristic
clean, low profile design is both
appealing and practically
functional. The WB Series utilizes
a clear, low brightness, extruded
acrylic refractor with injection
molded end caps for high
performance and good looks
The efficient and stylish wide
body WB Series is the perfect
wraparound for commercial
spaces, schools, dormitories,
offices and retail areas.
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : W B - 2 3 2 A - 1 2 0 V - E B 8 1 - U
Tandem
Blank=4' Length
8T=8' Length
WB=Series
Width
Blank=Standard
A=Wide Body for 2 Lamps
(3)
(1)
NOTES:
Products also available in non-US voltages and frequencies for international markets.
(3)
2 point suspension recommended.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
®
D I M E N S I O N S
NOMINAL LENGTH
A
4'/8' 2 Lamp
12" (305mm)
4'/8' 4 Lamp
18" (457mm)
Number of
Lamps
2 or 4 lamps
(Not Included)
Wattage (Length)
40=40W T12 (48")
32=32W T8 (48")
Lens
A=Acrylic Refractor/Lens
(1)
Voltage
120V=120 Volt
277V=277 Volt
347V=347 Volt
(2)
UNV=Universal Voltage 120-277
Options
GL=Single Element Fuse
GM=Double Element Fuse
Emergency - for EM installed, see EM options table
B
C
2-7/8" (73mm)
10-5/8" (270mm)
2-7/8" (73mm)
16-5/8" (422mm)
Options
(See Options
(1)
Ballast Type
Section)
LE3=T12 Magnetic Energy Saving
EB8 = T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
No. of
Harmonic Distortion < 20%
Ballast
1, 2 or 3
ER8 = T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB2 =T12 Electronic Rapid Start.
No. of Ballast
1 or 2
(For complete details on generic or to specify
manufacturer's ballast see pg. 469)
(2)
Not available when specifying emergencies, voltage must be specific.