Aimco AcraDyne Phoenix II User Manual

Aimco AcraDyne Phoenix II User Manual

Torque wrench
Hide thumbs Also See for AcraDyne Phoenix II:

Advertisement

Phoenix II/Phoenix III Torque Wrench
User Manual
10000 SE Pine St., Portland, OR 97216 • 800-852-1368 • 503-254-6600
www.aimco-global.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AcraDyne Phoenix II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aimco AcraDyne Phoenix II

  • Page 1 Phoenix II/Phoenix III Torque Wrench User Manual 10000 SE Pine St., Portland, OR 97216 • 800-852-1368 • 503-254-6600 www.aimco-global.com...
  • Page 2: Table Of Contents

    Phoenix II/Phoenix III Torque Wrench User Manual Table of Contents 1. General Power Tool Safety Warnings . Wrench General Configuration . . 14 6.3.1 General . 14 Battery and Charger. 6.3.2 Wi-fi Connection . 14 Accessories 6.3.3 Network address . 15 Tool Usage and Workplace Condition .
  • Page 3: General Power Tool Safety Warnings

    Phoenix II/Phoenix III Torque Wrench User Manual General Power Tool Safety Warnings manufacturer. Doing so may decrease the safety of the product and reduce its performance, life, or cause product failure. WARNING • To change accessories, follow the instruction manual. Read all safety warnings, instructions, illustrations, and •...
  • Page 4: Product Description

    Phoenix II/Phoenix III Torque Wrench User Manual Product Description 3.1.2 USB Interface The Phoenix II/Phoenix III torque wrench is a world class design tailored for industrial applications. It offers in a single product, a variety of tightening strategies for use in production environments and a set of methods and software features for evaluating the Version USB 2.0...
  • Page 5: Dimension And Weight

    Phoenix II/Phoenix III Torque Wrench User Manual 3.1.5 Dimension and Weight 38mm (1.5") 274.5mm (10.8") Figure 1 - Wrench drawing Capacity Drive Connector Weight (without end fitting) Model PHOENIX III 15 9 x 12 16.8 0.95 PHOENIX III 30 9 x 12 16.8 0.95 PHOENIX III 70 9 x 12...
  • Page 6: Battery Charger Model Phx Ii Batt Cgr

    Phoenix II/Phoenix III Torque Wrench User Manual Battery Charger Model PHX II BATT CGR TWConfig is a lightweight application that does not have a minimum computer requirement. If a given computer hardware runs a supported operating system version, then the application will run without issues.
  • Page 7: Wrench Operation

    Phoenix II/Phoenix III Torque Wrench User Manual The status bar is at the top of the screen and offers Battery level very low. Wrench may turn the user quick information about the wrench off automatically at any time operation state. On the left side of the status bar, the battery level, Wi-fi status, and other information Battery fuel-gauge error.
  • Page 8: Tightening Screen

    Phoenix II/Phoenix III Torque Wrench User Manual Tightening Screen The picture below shows a typical tightening screen for a torque only program. On the left side, an analog gauge that follows the applied force gives a more natural feel of the torque needed to reach the target. Current identifier/barcode Program target and limits Torque value display...
  • Page 9: Program Selection

    Phoenix II/Phoenix III Torque Wrench User Manual the navigation keys to type in the identifier. The input can be canceled at any time by pressing Go-back The input can be erased by using the Backspace virtual button or by holding the Shift key and pressing Go-back The behavior of the Enter key changes whether...
  • Page 10: Routes

    Phoenix II/Phoenix III Torque Wrench User Manual Routes Pressing Right shows the details of the program Selecting Routes in the main menu will display used to perform the highlighted tightening. This the route selection screen. The route is built in information is not the current program stored in the a hierarchical fashion, like file and folders in a wrench, but a copy stored with the result when the...
  • Page 11: Pan

    Phoenix II/Phoenix III Torque Wrench User Manual 5.5.1.2 Fair Battery is usable but may hold less than 60% of its rated capacity and Down pans the trace vertically and Poor Battery is near the end of its life. Plan to replace it Left and Right...
  • Page 12: Wrench Management Software Twconfig

    Phoenix II/Phoenix III Torque Wrench User Manual Wrench Management Software TWConfig Basic Operation TWConfig is a windows-based software package developed to manage the Phoenix II/Phoenix III torque wrench. It’s lightweight and offers an intuitive and easy-to-use interface for managing the wrench via a USB cable or Wi-fi connection.
  • Page 13: Open

    Phoenix II/Phoenix III Torque Wrench User Manual 6.2.1.2 Open 6.2.2 Connection Disconnected: Open a file for viewing and editing. It’s possible to connect to the wrench using the USB Previous saved results and traces can port or via Wi-fi using a TCP/IP connection. be viewed and exported.
  • Page 14: Wrench Configuration

    Phoenix II/Phoenix III Torque Wrench User Manual 6.3 Wrench General Configuration If an error occurs while trying to connect with the wrench, contact your IT department, providing From the TWConfig main interface, select General them the error shown, the address of the wrench, configuration and the following screen is displayed: and which computers are being used to connect.
  • Page 15: Network Address

    Phoenix II/Phoenix III Torque Wrench User Manual 6.3.3 Network address 6.4.1 Creating and Editing a Program The IP address and network mask are the two basic The steps to create or edit an existing program are network configurations that must be entered in basically the same.
  • Page 16: Method

    Phoenix II/Phoenix III Torque Wrench User Manual 6.4.1.2 Method in P0.28 is used. If both values are zero, a default of Sets the program strategy and strategy option to be 1 is used. This value changes the torque read in the used.
  • Page 17: Retightening And Loosening Detection

    Phoenix II/Phoenix III Torque Wrench User Manual the tightening if a cycle is started and the torque Loosening detection is kept below Start torque for this amount of time. The loosening of a bolt already tightened can If zero, the default set in P0.8 is used, usually the be detected by setting the loosening torque and default is 5000ms.
  • Page 18: Torque & Angle

    Phoenix II/Phoenix III Torque Wrench User Manual 6.4.4.2 Torque with angle monitoring 6.4.4.4 Automatic breakaway/ residual torque This strategy is similar to the torque strategy but The automatic breakaway strategy is used for also classifiesd the angle value according to a set a quality control check, and automatically window.
  • Page 19: Results

    Phoenix II/Phoenix III Torque Wrench User Manual the residual torque as shown in Figure 27 and more can be used to download more results to the Figure 28, ignoring the breakaway peak if local computer. present. 2. Breakaway torque: The wrench will always collect the breakaway torque as shown in Figure 27 and Figure 28.
  • Page 20: Angle Calibration

    Phoenix II/Phoenix III Torque Wrench User Manual used by the wrench, the wrench capacity is shown as a quick information of maximum torque that may be applied. As the formula in the lower part of the screen indicates the wrench torque (Tv) is calculated by dividing the ADC points (Adp) by the calibration factor (cf).
  • Page 21: Groups

    Phoenix II/Phoenix III Torque Wrench User Manual programs to be performed along with configurations such as how many times it should be executed. The route program is separated from the wrench programs so both can co-exist in the same wrench, deleting a route has no affect in the wrench programs and modifying the wrench programs has no effect in the route.
  • Page 22 Phoenix II/Phoenix III Torque Wrench User Manual Figure 35 - Route test The ID is a unique number used to identify the test in the result list (this number is saved with the results), this number is automatically assigned but can be changed by the user.
  • Page 24 AIMCO CORPORATE HEADQUARTERS AIMCO CORPORATION DE MEXICO SA DE CV 10000 SE Pine Street Ave. Cristobal Colon 14529 Portland, Oregon 97216 Chihuahua, Chihuahua. 31125 Phone: (503) 254–6600 Mexico Toll Free: 1-800-852-1368 Phone: (01-614) 380-1010 Fax: (01-614) 380-1019 LIT-MAN985 Rev. 06-23-23...

Table of Contents