Read and understand this material before operating or servicing this equipment. Failure to understand how to safely operate this tool can result in an accident causing serious injury or death.
SAFETY ALERT SYMBOL
This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage. The signal word, defined below, indicates the severity of the hazard. The message after the signal word provides information for preventing or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result in severe injury or death.
Hazards which, if not avoided, COULD result in severe injury or death.
Hazards which, if not avoided, MAY result in injury.
ELECTRIC SHOCK HAZARD
Failure to observe these precautions may result in severe injury or death.
Failure to observe these precautions can result in injury and can damage the instrument.
This manual is intended to familiarize personnel with the safe operation and maintenance procedures for the Tempo 200GX Inductive Amplifier.
Please read this entire manual before operating the tool and keep this manual available to all personnel. Replacement manuals are available upon request at no extra charge.
Safety is essential in the use and maintenance of Tempo tools and equipment. This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool. Observe all of the safety information provided.
Tempo's 200GX Inductive Amplifier, when used in conjunction with any Tempo tone generator, allows you to trace and troubleshoot a variety of electrical circuits (communication, alarm/security, automotive, etc.) without piercing the insulation.
Features include:
NOTE:
To use the 200GX without pressing the POWER button, perform either one of the following:(both methods will bypass the speaker and show a visual indication only)
Electrical | |
Gain | 30dB |
Input Impedance | 100M Ohm |
Probe Tip Resistance (min) Plastic Tip | 300 Ohm |
Battery | One 9V (NEDA 1604, JIS 006P, or IEC 6LR61) |
Battery Life (nominal) | 50 hours |
Physical | |
Length | 229 mm (9.0") |
Width | 48 mm (1.875") |
Depth | 35 mm (1.375") |
Weight | 0.13 kg (4.6oz) |
Operating/Storage Conditions | |
Temperature: | |
Celsius | 0°C to 50°C |
Fahrenheit | 32°F to 122°F |
Before opening the case, remove the test leads from the circuit and shut off the unit. Failure to observe these warnings can result in severe injury or death.
Periodically wipe with a damp cloth and mild detergent; do not use abrasives or solvents.
Tempo – Mesa | Formerly Progressive Electronics
Telephone: +1 815 397-4279
Toll-free in the US and Canada: 1 800 282-7941
Facsimile: +1 815 397-1865
www.tempo.textron.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.