[User Manual] CONTENTS 1、SUMMARY .................................. 3 2、INTERFACE .................................. 4 2.1 S ERIAL ABLE NTERFACE ............................4 2.2 RF I NTERFACE ..................................5 3、FUNCTION AND OPERATING INSTRUCTIONS ....................5 3.1 P OWER ..................................5 3.2 P OWER SHIFT ..................................5 3.3 T RANSMITTING CHANNEL SHIFT ............................
Page 3
This products operation manual and all the related software are protected by Harxon Corporation, and all rights reserved. All rights of this manual include copyright only belongs to Harxon Corporation (short for Harxon as below), unless the copyright holders allowed, strictly forbid to copy this manual by printing、xeroxing、recording and other means.
[User Manual] 1、Summary 1601D is an external Receipt &Transmission 1W radio modem, waterproof to IP67、 Durable structure,which can apply to all outdoor weather conditions. 1601D has 4 pieces of LED、1 piece of nixie tube and 3 pieces of push-button, for user’s convenience of booting、...
[User Manual] Interface type: asynchronous serial communication standard of RS232 Pin definitions: Pin 1------Power,9-16V DC; Pin 2------power grounding,Power GND; Pin 3------serial data receiver,RXD; Pin 4------serial signal grounding; Pin 5------serial data transmission,TXD. 2.2 RF interface 1601D RF interface is TNC female connector of 50Ω. 3、Function and operating instruction 3.1 Booting Press the button of ON/OFF to boot.
[User Manual] pressing for fast forward, digital tube display the current channel number. 3.4 Channel Display Operation Mode: Display the channel number of “1-8” transmitting rate. 3.5 Low voltage indicator While transmitting data,TX/RX LED indicator of ON will be red flash;While receving data, TX/RX LED indicator show green.
Page 7
[User Manual] 4.2 Make radio modem enter the configuration mode Connecting the power line and serial port line, which confirmed to be connected correctly, repower, press the button of “ON/OFF” for booting, LED indicator of ON show green. Within 3 seconds, click the butto to make the radio modem enter configuration mode, reading and saving the information of configured radio modem (shown as the chart below), button of “load”...
Page 8
[User Manual] 4.3 Configuring the parameter radio modem 4.3.1 Configuring the customized rate, defaulted rate as: There are two groups of defaulted rate value(transmitting and receiving frequency),click " def ault " below,Will set all the frequencies in the corresponding column。 4.3.2 Configuring the serial baud rate Serial baud rate optional 9600,19200,38400,57600,115200 bps.
[User Manual] 4.3.3 Configuring the current channel ch1-ch8 You can choose one channel as the current communication channel in the 1-8 channel,click button,Configuring Radio Parameters; Noted:Before Configuring Radio Parameters,click“Read” Button,First read all the configuration parameters of the machine, and then make the appropriate parameter modification;...
[User Manual] 5、Software upgrading Fault description Cause analysis Solution Power cable connection is not Cannot boot reliable or positive and negative Correctly connect power cable reversed Correctly configured serial baud Unable to enter configuration Serial port configuration is not rate and related parameters, click mode correct, improper operation the "Connect"...
Page 11
[User Manual] ≤±1.0ppm Frequency Stability 148×76×30mm Dimension -30℃~+60℃ Operating Temperature -55℃~+85℃ Storage Temperature TNC-Female Antenna Interface Antenna Interface 50ohm Impedance LEMO,HGG.1B.305 Data Power Interface Transmitter Performance Specifications Name Specifications (1W) 30±1dBm@DC12V High power RF output power (0.5W) 27±1dBm@DC12V Low power ±1dB RF Power Stability Adjacent Channel...
Need help?
Do you have a question about the UHF1601D and is the answer not in the manual?
Questions and answers