5. Remove the locking rings "M" and
push the pin "N" out. You can then
pull out the blades "O" and the slide
plates "P".
7. The work steps must be carried out in reverse order to fit the new parts.
ATTENTION!
Apply HURST special grease to all sliding surfaces!
NOTE:
The torque required can be taken from the spare parts list of your particular unit.
G
H
J
L
K
4. First remove the grub screw "G", then
the central bolt nut "H" and then pull out
the central pin "J".
M
N
6. Release the fixing screws "K" and
remove them. The handle "L" can now be
pulled out forwards.
31
N
M
P
O