Body Temperature Measurement Network Camera User Manual Precautions Precautions Precautions Fully understand this document before using this device, and strictly observe rules in this document when using this device. If you install this device in public places, provide the tip "You have entered the area of electronic surveillance" in an eye-catching place. Failure to correctly use electrical products may cause re and severe injuries.
Page 3
Body Temperature Measurement Network Camera Precautions User Manual Strictly conform to local electrical safety standards and use power adapters which are marked with the LPS standard when installing and using this device. Otherwise, this device may be damaged. Use accessories delivered with this device. The voltage must meet input voltage ...
Page 4
Body Temperature Measurement Network Camera User Manual Precautions Use a soft and dry cloth to clean the device body. In case that the dirt is hard to remove, use a dry cloth dipped in a small amount o f mild detergent and gently wipe the device, and then dry it again.
Body Temperature Measurement Network Camera Contents User Manual Contents Precautions ............................I Contents .............................. IV 1 Product Overview ........................1 About Product ......................... 1 Features .......................... 1 Device Dimen ......................... 2 Cable Connection ......................5 2 Quick Con guration ........................7 Login and Logout ......................
Page 6
Body Temperature Measurement Network Camera User Manual Contents Accessing the Sensor Interface ..................43 Mode ..........................43 Images .......................... 44 Scene ..........................45 Set Pseudocolor ......................46 FFC Control ......................... 47 Noise Reduction ......................49 Enhance Image ......................50 6 Intelligent Analysis ........................
Page 7
Body Temperature Measurement Network Camera Contents User Manual Maintenance ....................... 81 Local Config ....................... 82 A Troubleshooting ......................... 83 Issue V1.0 ( 2020-03-17 )...
Body Temperature Measurement Network Camera User Manual Product Overview Product Overview About Product T he Body Temperature Measurement Network Camera is integrated with the thermal imaging and temperature measuring, visible fusion, core image intelligent analysis, etc. Unique double registration mechanism, visible light and therma limaging is ...
Body Temperature Measurement Network Camera Product Overview User Manual In the heat setting temperature measuring points in the image or temperature area, temperature detection and display: point temperature measurement, regional temperature measuring, full screen, temperature measurement Over-temperature warning, temperature di erence alarm and over-temperature ...
Page 10
Body Temperature Measurement Network Camera User Manual Product Overview Issue V1.0 ( 2020-03-17 )...
Page 11
Body Temperature Measurement Network Camera Product Overview User Manual Issue V1.0 ( 2020-03-17 )...
Body Temperature Measurement Network Camera User Manual Product Overview Cable Connection Figure 1-2 the multi - connector combination cable of the thermal imaging integrated network camera. For details about the multi-connector combination cable, please refer to Table 1-1. Multi-connector combination cable Multi-connector combination cable Core of Cable Functions...
Page 13
Body Temperature Measurement Network Camera Product Overview User Manual Audio Input Inputs the audio signal and receives the analog audio signals from the sound pick -up device. A udio Output Connects to the external audio device such as the voice box. DC12V (2A) Power interface, connects to the 12 V DC power supply.
Body temperature Measurement Network camera User Manual Quick Configuration Quick Con guration Login and Logout You must use Internet Explorer 8 or a later version to access the web management system; otherwise, some functions may be unavailable. Login system Open the Internet Explorer, enter the IP address of camera (default value is 192.168.0.121) in the address box, and press Enter.
Body Temperature Measurement Network Camera Quick Configuration User Manual logout To logout of system, click in the upper right corner of the homepage, the login page is displayed after you log out of the system. Homepage Layout On the home page, user can view real-time video, playback and con guration. User can set parameter, Video parameter, Video control, PTZ control, PTZ Con gure and logout of the system.
Page 16
Body temperature Measurement Network camera User Manual Quick Configuration Element Description Alarm icon When the device generates an alarm, the alarm icon is displayed. You can click to view the alarm information. When the device accepts an alarm signal, the alarm icon will display within 10s in the web management system .
Body Temperature Measurement Network Camera Quick Configuration User Manual Element Description turned on the function in IAS settings. ---- End Changing the Password Description User can click to change the password for logging in to the system. Procedure Click in the upper right corner of the main page. The Change Password dialog box is displayed, as shown in Figure 2-3.
Body temperature Measurement Network camera User Manual Quick Configuration T he change password page will be displayed if you don’t change the default password when you login the system for the rst time. Input the old password, new password, and con rm password. Click OK.
Page 19
Body Temperature Measurement Network Camera Quick Configuration User Manual Adding the a trusted site In the Internet Explorer, choose Tool > Internet Options > Security > Customer level, and set Download unsigned ActiveX control and initialize and script ActiveX controls not marked as safe for scripting under ActiveX controls and plugins to Enable, as shown in Figure 2-5.
Body temperature Measurement Network camera User Manual Quick Configuration Con guring ActiveX control and plug-ins Download and install the player control as prompted. The login page is displayedwhen the control is loaded. Install Plugins You will be prompted with a message “click here to use short delay Plugin for Live Video”...
Body Temperature Measurement Network Camera Quick Configuration User Manual Procedure Click the message, download and install the plugin follow the prompts. R eopen the browser after installation . On live video page, you can operate these buttons as shown in live video. Channel switch, choose channel 1view the visible picture, channel 2 is ...
Page 22
Body temperature Measurement Network camera User Manual Quick Configuration Device information Set the parameters according to Table 2-2. Local network parameters Parameter Description Setting IP Protocol IPv4 is the IP protocol that uses [Setting method] an address length of 32 bits. Select a value from the drop-down list box.
Page 23
Body Temperature Measurement Network Camera Quick Configuration User Manual Parameter Description Setting IP Address Device IP address that can be [Setting method] set as required. Enter a value manually. [Default value] 192.168.0.121 Subnet Mask Subnet mask of the network [Setting method] adapter.
Page 24
Body temperature Measurement Network camera User Manual Quick Configuration If you set only the Subnet Mask, Default Gateway, Preferred DNS Server, and Alternate DNS Server parameters, you do not need to log in to the system again. You can click Reset to restore the previous parameters if required. ...
Body Temperature Measurement Network Camera Human Thermometer Setting User Manual Human Thermometer Setting Parameter Con gure Operation Procedure Choose Con guration >human thermometer >parameter con gure. The parameter con gure page is displayed, as shown in Figure 3-1. Temperat u re Parameters interface Issue V1.0 (...
Page 26
Body Temperature Measurement Network Camera User Manual Human Thermometer Setting Set the parameters according to Table 3-1. Parameter of face detection Parameter Description Setting Face detection Detect face of human [Setting method] E nable [Default value] Display trace Display the information of [Setting method] tracing.
Page 27
Body Temperature Measurement Network Camera Human Thermometer Setting User Manual Mode 1 Mode 1 : Show detection area Enable, the live video will show [Setting method] area of detection. E nable Con dence Face detection sensitivity, the [Setting method] coe cient value range is high, medium, Choose from drop -list low, the larger the value is, the...
Page 28
Body Temperature Measurement Network Camera User Manual Human Thermometer Setting interval set the interval. Input a number from 1 to [Default value] Snapshot count A t optimal mode, set the [Setting method] number of snapshot image Input 1 Y aw degree(0 -90) Both eyes appear on the screen, [Setting method] o set in the left and right...
Page 29
Body Temperature Measurement Network Camera Human Thermometer Setting User Manual Temperature parameters Temperature parameters Parameter Description Setting Temperature Unit Celsius and Fahrenheit [Setting method] temperature units are available. Select a value from the drop-down list box. [Default value] Celsius Ambient Type The ambient of camera.
Page 30
Body Temperature Measurement Network Camera User Manual Human Thermometer Setting Parameter Description Setting Correction Correction coe cient refers to [Setting method] Coe cient the deviation of measured Enter a value manually. object temperature and actual [Default value] temperature . 0.00 For example: 1.
Page 31
Body Temperature Measurement Network Camera Human Thermometer Setting User Manual Face alarm linkage Temperature parameters Parameter Description Setting Output channel Choose channels to output [Setting method] alarm T ick the channels [Default value] Uncheck A larm rules Set the maximum temperature [Default value] greater than set value Maximum temperature...
Body Temperature Measurement Network Camera User Manual Human Thermometer Setting SMTP E nable, when there is an alarm, [Setting method] the camera will send mail. E nable FTP upload E nable, when there is an alarm , [Setting method] the camera will upload FTP. E nable ---- End Schedule Linkage...
Body Temperature Measurement Network Camera Human Thermometer Setting User Manual NOT E Method 1: Click left mouse button to select any time point within 0:00-24:00 from Monday to Sunday as shown in Figure 3-4. Method 2: Hold down the left mouse button, drag and release mouse to select the alarm ...
Body Temperature Measurement Network Camera User Manual Human Thermometer Setting Settings please refer to Table 3-4. Parameter of thermal mapping Parameter Description Setting Zoom in /zoom out. [Setting method] Click the button Near focus / far focus. [Setting method] Click the button L ock focus [Setting method] position...
Page 35
Body Temperature Measurement Network Camera Human Thermometer Setting User Manual Operation Procedure Choose Con guration >human thermometer >bad point check, if there are some bad point as shown in Figure 3-6. Bad point check interface B a d P oint 1 B a d P oint 2 Click the white point at image, click Apply to recover the bad point, as shown in Figure 8-5...
Body Temperature Measurement Network Camera User Manual Human Thermometer Setting Recover bad point Click Reset to return the previous settings. Click Apply. The message "Apply success" is displayed, the system saves the settings . ---- End Thermal Calibration Enable the thermal calibration function; you need the special calibration tool to check the temperature, input the target temperature (the special calibration tool s temperature), ’...
Page 37
Body Temperature Measurement Network Camera Human Thermometer Setting User Manual Thermal calibration interface Enable the button and display area info. Input the target temperature, emission rate and distance. Click Apply. The message "Apply success" is displayed, the system saves the settings.
Body Temperature Measurement Network Camera User Manual Visible Sensor Configuration Visible Sensor Con guration Accessing the Sensor Interface Procedure On the web or NVMS interface, move the cursor to the real-time video page and right- click on the page. A shortcut menu is displayed, as shown in Figure 4-1 Sensor setting interface Choose Sensor Con gure and the Sensor Setting dialog box appears.
Body Temperature Measurement Network Camera Visible Sensor Configuration User Manual Mode Choose the switch mode from the drop-down list. T ime mode: Set the Start Time, set the End Time. DN linkage Mode, the day mode is correspond to scheme 1, the night mode is correspond to scheme 2. Click Save, the message "Save succeed"...
Page 40
Body Temperature Measurement Network Camera User Manual Visible Sensor Configuration Parameters of Image Con guration Parameter Description Method Brightness It indicates the total brightness of an image. As [Setting method] the value increases, the image becomes Drag the slider. brighter. [Default value] Sharpness It indicates the border sharpness of an image.
Body Temperature Measurement Network Camera Visible Sensor Configuration User Manual Scene Figure 4-4 shows the scene tab page. Scene Table 4-2 describes the parameters on the scene tab page. Parameters of scene Con guration Method Parameter Description Scene Indoor or outdoor . [Setting method] Select a value from the drop -down list.
Body Temperature Measurement Network Camera User Manual Visible Sensor Configuration Exposure Figure 4-5 shows the Exposure tab page. Exposure Table 4-3 describes the parameters on the Exposure setting tab page. Parameters of exposure setting Con guration Parameter Description Method Exposure Mode The exposure modes include: [Setting method]...
Page 43
Body Temperature Measurement Network Camera Visible Sensor Configuration User Manual Max Shutter It is valid in mode. You can [Setting Iris Priority select a maximum shutter speed. As the method] value increases, the image becomes Select a value brighter. from the drop - down list.
Body Temperature Measurement Network Camera User Manual Visible Sensor Configuration Parameters of WB Con guration Parameter Description Method Mode It is used to display the real color of a [Setting monitoring scenario when the color temperature method] changes. Select a value from the drop - A uto: camera adjusts automatically .
Page 45
Body Temperature Measurement Network Camera Visible Sensor Configuration User Manual Parameters of day night Con guration Parameter Description Method It can be set to Auto, Day Mode, Night [Setting method] DayNight Mode and Timing. Mode Select a value from the drop - A uto mode ...
Body Temperature Measurement Network Camera User Manual Visible Sensor Configuration Noise Reduction Figure 4-8 shows the noise reduction tab page. Noise R eduction Table 4-6 describes the parameters on the Special Function tab page. Parameters of noise reduction Con guration Parameter Description Method...
Page 47
Body Temperature Measurement Network Camera Visible Sensor Configuration User Manual Enhance image Table 4-7 describes the parameters on the enhance image setting tab page. Parameters of enhance image Con guration Parameter Description Method It is intended to provide clear image [Setting method] performance in strong backlight areas such as Drag the slider.
Body Temperature Measurement Network Camera User Manual Visible Sensor Configuration Anti-shake W hen the camera shakes out, it is processed [Default value] by algorithm compensation Disable Defog It indicates the camera defog automatically . [Setting method] Drag the slider. [Default value] Zoom Focus Figure 4-10 shows the enhance image Setting tab page.
Page 49
Body Temperature Measurement Network Camera Visible Sensor Configuration User Manual [Setting method] :zoom out Click :zoom in :near focus :far focus A uto focus [Setting method] once Click L ens [Setting method] initialization Click Issue V1.0 ( 2020-03-17 )...
Body Temperature Measurement Network Camera User Manual Thermal Sensor Configuration Thermal Sensor Con guration Accessing the Sensor Interface Operation Procedure On the Internet Explorer interface or the client software interface, choose channel 2 select and right click the surveillance image to the set, as shown in Figure 5-1. Sensor con guration Choose Sensor.
Body Temperature Measurement Network Camera Thermal Sensor Configuration User Manual Mode interface Operation Procedure in the lower left corner of Sensor Setting, and choose Debug Click Mode . Choose switch mode from the drop down list T ime mode: Set the Start Time, set the End Time. DN linkage Mode, the day mode is correspond to scheme 1, the night mode is correspond to scheme 2.
Body Temperature Measurement Network Camera User Manual Thermal Sensor Configuration Image setting interface Click in the lower left corner of Sensor Setting, and choose Debug Mode . Drag the slider to adjust parameter of image. Click Save, the message "Save succeed" is displayed, the system saves the settings. NOT E Brightness :It indicates the total brightness of an image.
Body Temperature Measurement Network Camera Thermal Sensor Configuration User Manual Scene setting interface in the lower left corner of Sensor Setting, and choose scene Click Choose mirror mode from drop-list. Click Save, the message "Save succeed" is displayed, the system saves the settings. NOT E Mirror providing the selection of image pixel locations.
Body Temperature Measurement Network Camera User Manual Thermal Sensor Configuration Set pseudocolor setting interface Click in the lower left corner of Sensor Setting, and choose set pseudo color Choose polarity/LUT mode from drop-list. Enable or disable the temperature strip switch Click Save, the message "Save succeed"...
Page 55
Body Temperature Measurement Network Camera Thermal Sensor Configuration User Manual FFC control interface Table 5-1 lists the parameters on the FFC control interface. Parameters on the FFC control interface Parameter Description Setting The internal of the thermal imaging camera may comprise the mechanical action correction mechanism that can periodically improve the image quality.
Body Temperature Measurement Network Camera User Manual Thermal Sensor Configuration Parameter Description Setting The temperature change of the camera is based on the temperatures collected by the internal temperature probe. The temperature of the camera sharply changes when the camera is powered on.
Body Temperature Measurement Network Camera Thermal Sensor Configuration User Manual Noise reduction interface Table 5-2 lists the Noise reduction parameters. Parameters on the Noise reduction interface Parameter Description Setting [How to set] Select from the drop -down list box. Decrease the image 2DNR noise.
Page 58
Body Temperature Measurement Network Camera User Manual Thermal Sensor Configuration Enhance image interface Click in the lower left corner of Sensor Setting, and choose enhance image . T ick defog, then drag the slider to set. It ranges from 0-100, the default value is 50. Click Save, the message "Save succeed"...
Body Temperature Measurement Network Camera Intelligent Analysis User Manual I ntelligent Analysis Perimeter Description The perimeter function refers to that an alarm is generated when the targets of speci ed types (such as person, car, and both person and car) enter the deployment area. Procedure Select Con guration >...
Page 60
Body Temperature Measurement Network Camera User Manual Intelligent Analysis Perimeter Parameter Description Parameter Description Setting Channel Channel 1: visible. Choose one channel to set. Channel 2: thermal . Enable Enable the button to enable [How to set] the alarm. Click Enable to enable. [Default value] Limit E ective alarms are set based...
Page 61
Body Temperature Measurement Network Camera Intelligent Analysis User Manual Parameter Description Setting Output If you check to set the Output [How to set] Channel Channel and the device is Click to select an ID. connected to an external alarm indicator , the alarm indicator signals when an alarm is triggered.
Body Temperature Measurement Network Camera User Manual Intelligent Analysis A drawn line cannot cross another one, or the line drawing fails. Any shape with 32 sides at most can be drawn. The quantity of deployment areas is not limited yet and will be described in future when ...
Page 63
Body Temperature Measurement Network Camera Intelligent Analysis User Manual Procedure Select Con guration > Intelligent Analysis > Single Virtual Fence to access the Single Virtual Fence setting interface, as shown in Figure 6-3. Single Virtual Fence Setting Interface of speci ed types (such as person or car) cross this line. Set all parameters for the single virtual fence.
Page 64
Body Temperature Measurement Network Camera User Manual Intelligent Analysis Parameter Description Setting Limit Target Type E ective alarms are set based [How to set] on target type, with options of Click t o enable Limit Person or Car, person , car. Target Type.
Page 65
Body Temperature Measurement Network Camera Intelligent Analysis User Manual Parameter Description Setting Alarm Record [How to set] Enable the button to enable the Click to enable Alarm alarm record. Record. [Default value] SMTP Enable the button to enable [How to set] SMTP sever.
Body Temperature Measurement Network Camera User Manual Intelligent Analysis NOT E A single virtual fence is not within any deployment area, therefore, when an alarm is generated, the trace always exists. Only when the target object moves out of the eld of view, the trace disappears.
Page 67
Body Temperature Measurement Network Camera Intelligent Analysis User Manual Double Virtual Fences Setting Interface Set all parameters for the double virtual fences. Table 6-3 describes the speci c parameters . Description of Parameters for Double Virtual Fence Parameter Description Setting Channel Channel 1: visible.
Page 68
Body Temperature Measurement Network Camera User Manual Intelligent Analysis Parameter Description Setting Limit The target size for triggering an [How to set] Target Size e ective alarm is set based on the Click to enable Limit actual target size. The minimum size Target Size.
Page 69
Body Temperature Measurement Network Camera Intelligent Analysis User Manual Parameter Description Setting Enable the button to enable File [How to set] Upload Transfer Protocol. Click to enable FTP . [Default value] PTZ Type [How to set] Set PTZ type for dome cameras and select corresponding PTZ type : Select from the drop - Preset/Scan/Track/Tour .
Body Temperature Measurement Network Camera User Manual Intelligent Analysis Object Left Description The object left function refers to that an alarm is generated when the dwelling time of an object with in the deployment area meets the set s h ortest dwelling time. Procedure Select Con guration >...
Body Temperature Measurement Network Camera Intelligent Analysis User Manual NOT E A drawn line cannot cross another one, or the line drawing fails. Any shape with 32 sides at most can be drawn. T he quantity of deployment areas is not limited yet and will be described in future when ...
Page 72
Body Temperature Measurement Network Camera User Manual Intelligent Analysis Set all parameters for o bject removed. Table 1-1 describes the speci c parameters . Description of Parameters for Object Removed Table 1 -1 Parameter Description Setting Channel Channel 1: visible. Choose one channel to set.
Page 73
Body Temperature Measurement Network Camera Intelligent Analysis User Manual Parameter Description Setting Alarm Record Enable the button to enable the alarm [How to set] record. Click to enable Alarm Record. [Default value] SMTP Enable the button to enable SMTP [How to set] sever.
Body Temperature Measurement Network Camera User Manual Alarm Setting Alarm Setting Alarm Output Procedure Select Con guration > alarm > alarm output to access the alarm output setting interface, as shown in Figure 7-1. Alarm output interface Set alarm output of channel, name, enable valid signal and alarm time choose alarm output mode.
Body Temperature Measurement Network Camera Alarm Setting User Manual Disk alarm interface Enable the disk full alarm. Set alarm interval , the value is from 10 to 86400 s. T ick the channel to push alarm message. Click apply to save the settings, click refresh will return last settings. Network Alarm Procedure Select Con guration >...
Body Temperature Measurement Network Camera User Manual Alarm Setting Network alarm interface Choose network card ID and enable exceptional alarm to set alarm interval. Tick output channel. E nable the alarm record . Click apply to save the settings, click refresh will return last settings. I/O Alarm Linkage Procedure Select Con guration >...
Body Temperature Measurement Network Camera Alarm Setting User Manual I/O alarm linkage interface Choose alarm input and trigger mode, set name, enable other linkages such as alarm input, PTZ linkage, alarm record, SMTP and FTP upload. Set alarm schedule, choose the duration of linkage. Click apply to save the settings, click refresh will return last settings.
Body Temperature Measurement Network Camera User Manual Alarm Setting Motion alarm interface Choose channel and enable the motion alarm , set alarm interval and sensitivity. enable other linkages such as alarm record, SMTP and FTP upload. Set motion alarm schedule, Click apply to save the settings, click refresh will return last settings.
Page 79
Body Temperature Measurement Network Camera Alarm Setting User Manual Push message interface Enable the push message, you will receive the message when the alarm happened. Click apply to save the settings, click refresh will return last settings. Issue V1.0 ( 2020-03-17 )...
Body Temperature Measurement Network Camera User Manual Other Web Configurations Other Web Con gurations D evice Information You can view the information about device, as shown in Figure 8-1. Device information interface Stream Base Stream Choose con guration >stream >base stream, as shown in Figure 8-2. Issue V1.0 (...
Body Temperature Measurement Network Camera Other Web Configurations User Manual Base stream interface Choose channel, stream ID, video encode type, video encode level, audio encode type, resolution, frame rate, frame interval, bit rate type and bit rate from all drop list.
Body Temperature Measurement Network Camera User Manual Other Web Configurations SVC stream interface Choose SVC stream ID, elementary stream ID and P frame rate from drop list. Click Apply. The message "Apply success" is displayed, the system saves the settings. Choose con guration >stream >ROI, as shown in Figure 8-4.
Body Temperature Measurement Network Camera Other Web Configurations User Manual Snapshot Choose con guration >stream >snapshot, as shown in Figure 8-5. Snapshot interface Choose snapshot resolution and snapshot quality from drop list. Click Apply. The message "Apply success" is displayed, the system saves the settings.
Body Temperature Measurement Network Camera User Manual Other Web Configurations Device interface External Device Choose con guration >external device, enable PTZ, set parameters as shown in Figure 8-7. External device interface Issue V1.0 ( 2020-03-17 )...
Body Temperature Measurement Network Camera Other Web Configurations User Manual D evice Record Choose con guration > device record, enable schedule record, set post record, record audio, record rule (cycle store or save days) and stream name. At this interface, you can also view or modify the information of record directory.
Body Temperature Measurement Network Camera User Manual Other Web Configurations Privacy masking interface Network Service Choose con guration > network service. You can set 802.1x, DDNS, PPPoE, Port mapping, SMTP, IP lter, CGI alarm service center , SNMP and QOS. Privacy Manager Add user account, manage the users’...
Body Temperature Measurement Network Camera Other Web Configurations User Manual Privacy manager interface Protocol Choose con guration > protocol. You can set protocol information, security, CMS con guration and multicast parameter. Issue V1.0 ( 2020-03-17 )...
Body Temperature Measurement Network Camera User Manual Other Web Configurations Protocol interface D evice Log Choose con guration > device log. You can view operation log and alarm log, or collect all log information, as shown in Figure 8-12. Device log interface M ainten ance Choose con guration >...
Page 89
Body Temperature Measurement Network Camera Other Web Configurations User Manual Maintenance interface L ocal C on g Choose con guration > local con g. You can choose the snapshot picture format, change the save path of snapshot and local record , as shown in Figure 8-14. L ocal con g interface Issue V1.0 (...
Page 90
Body Temperature Measurement Network Camera User Manual A Troubleshooting Troubleshooting Common Trouble Possible Cause Solution Unable to access Network is not Connect the network cable of the camera to the the web connected. PC to check whether the network cable is in good contact.
Page 91
Body Temperature Measurement Network Camera A Troubleshooting User Manual Issue V1.0 ( 2020-03-17 )...