You need to configure the alarm input/output conditions on the ALARM SETTINGS screen.
The duration of recording initiated by each trigger is as follows.
ALARM IN1/ALARM IN2/MOTION: Time selected in [DURATION] under [ALARM IN] on ALARM
SETTINGS screen
ALARM OUT1/ ALARM OUT2: Time selected in [ALARM OUT TIME] under [ALARM OUT] on
ALARM SETTINGS screen
NETWORK FAILURE: Time until network failure is resolved
3
If you selected "NETWORK FAILURE" in [TRIGGER]
In [NETWORK FAILURE TIME], select the time from the occurrence of a network failure until the camera
recognizes it as a recording trigger.
15SEC, 20SEC, 30SEC, 40SEC, 50SEC, 1MIN, 2MIN, 3MIN, 4MIN, 5MIN
The setting values are interlocked among RECORDING, E-MAIL SETTINGS, and FTP SETTINGS
screens. (Note that the setting configured most recently will take precedence.)
4
To perform pre-alarm recording, in [PRE ALARM], select "ON".
You can now record the video for a specific period before and after the occurrence of an alarm.
If you selected "ON" in [PRE ALARM]
5
In [DURATION], select how long you want to perform pre-alarm recording.
5SEC, 10SEC, 15SEC, 20SEC, 30SEC, 45SEC, 1MIN, 2MIN, 3MIN, 4MIN, 5MIN
The pre-alarm recording duration setting applies commonly from the ALARM EVENT1 to ALARM
EVENT3 settings.
If you selected a JPEG stream in [RECORD STREAM], in [FRAME RATE], select the frame
6
rate of the stream.
Select the refresh rate of live video.
VDC-HD3500: 0.1ips, 0.2ips, 0.5ips, 1ips, 3ips, 5ips, 10ips, 15ips, 30ips
VDC-HD3500P: 0.1ips, 0.2ips, 0.5ips, 1ips, 2.5ips, 5ips, 8ips, 12.5ips, 25ips
Here, you can select a frame rate slower than that set for the stream.
If you selected an H.264 stream, you cannot change the frame rate set for the stream.
The frame rate setting will be applied commonly to the ALARM EVENT1 to ALARM EVENT3
settings.
* To configure the periods during which recording is activated, click
The SCHEDULE SETTINGS screen appears.
For details, refer to the "SCHEDULE SETTINGS" section.
This button is labeled "SCHEDULE ON" if the recording schedule has been configured.