Ouellet COMFORT OFEA 000-VV Series Installation Instructions Manual
Ouellet COMFORT OFEA 000-VV Series Installation Instructions Manual

Ouellet COMFORT OFEA 000-VV Series Installation Instructions Manual

Electric furnace
Hide thumbs Also See for COMFORT OFEA 000-VV Series:
Table of Contents

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS AND
HOMEOWNER'S MANUAL: ELECTRIC FURNACE
COMFORT & ADVANTAGE
(ECM MOTOR)
MULTI-POSITION
INSTALLER / SERVICE TECHNICIAN:
USE
THE
INFORMATION
INSTALLATION AND SERVICING OF THE FURNACE AND KEEP
THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE.
HOMEOWNER:
PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR
FUTURE REFERENCE.
Printed in Canada on
100% recycled paper
IN
THIS
MANUAL
Models:
OFEAxx000-VV
OFEAxx000-1HVV
www.ouellet.com
1 800 463-7043
Attention:
FOR
THE
Do not tamper with the unit or its controls.
Call a qualified service technician.
Manufactured by: Dettson Industries Inc.
Sherbrooke, Qc, Canada
www.dettson.com
2023-02-01
X40239 Rev.F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMFORT OFEA 000-VV Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ouellet COMFORT OFEA 000-VV Series

  • Page 1 INSTALLATION INSTRUCTIONS AND HOMEOWNER’S MANUAL: ELECTRIC FURNACE COMFORT & ADVANTAGE Models: (ECM MOTOR) OFEAxx000-VV OFEAxx000-1HVV MULTI-POSITION www.ouellet.com 1 800 463-7043 INSTALLER / SERVICE TECHNICIAN: Attention: INFORMATION THIS MANUAL Do not tamper with the unit or its controls. INSTALLATION AND SERVICING OF THE FURNACE AND KEEP Call a qualified service technician.
  • Page 2: Table Of Contents

    3.4 AIRFLOW VERIFICATION ......3.4.1 Supply Air Temperature Rise Test ..3.4.2 High limit verification .
  • Page 3: Safety

    technician for the installation and subsequent servicing of this furnace; b) Do not use this furnace if any part of it was under water. SAFETY Call a qualified service technician immediately to assess the damage and to replace all critical parts that were in contact with water;...
  • Page 4: Installation

    2.2.2 Supply air ducts Ducts can be installed with a zero clearance to combustible material. 2 INSTALLATION 2.3 CONFIGURATIONS This furnace requires suitable ductwork. This furnace is a true multi-position unit, in that it will function in an upflow, downflow or horizontal configuration to the left or the right.
  • Page 5: Suspended Installation

    shall be installed on the top of the unit. terminal is supplied with the control box for that purpose. When the furnace is installed in the horizontal position, A connector is supplied on the ground terminal to ground either suspended or on a combustible floor with a choice an added accessory.
  • Page 6: Anticipator Adjustment (If Required) On Thermostat Equipped With Heat Anticipator Adjustment

    Figure 5: 1-stage thermostat, electric heating only Figure 2-stage heating & 1-stage conditioning & heat pump thermostat Figure 2-stage heating & 2-stage conditioning & heat pump thermostat dehumidification mode Figure 6: 2-stage thermostat, electric heating only 2.5.1 Anticipator adjustment (if required) on thermostat equipped with heat anticipator adjustment Some thermostats are equipped with a heat anticipator...
  • Page 7: Supply Air Adjustments

    Figure 10: Fan control board codes. Insulate the ducts that lead through non-heated areas. Use flexible supply and return air connectors to avoid the transmission of vibration. To make the unit run even quieter, the installer should: 1. Use two elbows between each outlet and the supply and return air plenum;...
  • Page 8: Ac/Hp Cfm Adjust

    1. AC – Air Conditioner provides approximately 400 70% airflow, and no OFF delay for added comfort. CFM per ton for greater efficiency and humidity This profile will minimize cold blow in heat pump control with the AC/HP CFM ADJUST set to the operation and could enhance system efficiency.
  • Page 9: Installation Of Accessories

    2.7.3 Dehumidify capability with standard 2.7 INSTALLATION OF humidistat connection ACCESSORIES Latent capacities for systems using this unit are better than average systems. If increased latent capacity is an application requirement, the field wiring terminal block WARNING provides a connection terminal (DH) for use of a standard humidistat.
  • Page 10: Use Of Manual Furnace Controls On Advantage Furnace

    3.3.2 Cooling mode - single stage 3.2 USE OF MANUAL FURNACE NOTE: For single stage systems, do not use the Y1 CONTROLS ON ADVANTAGE terminal. FURNACE a. If indoor temperature is above temperature set point and humidity is below humidity set point, When there is a demand for heat, the pilot light (L-1) thermostat closes circuits R to G, R to Y/Y2 and comes on.
  • Page 11: Airflow Verification

    3.3.8 Heat pump heating mode – m (12”) from the plenum of the main take-off is usually sufficient; Modulating thermostat, outdoor unit two stage 4. Calculate the temperature rise by subtracting • First stage (low) heating: Thermostat closes the return air temperature from the supply air circuits R to G and R to Y1.
  • Page 12: Air Filter

    4.1 AIR FILTER points: 1. Check fuses or the circuit breakers; The disposable filter should be replaced twice a year. 2. Check if the 15 A circuit breaker on the furnace is The presence of animal hair, dust, etc. may necessitate disengaged;...
  • Page 13: Furnace Information

    FURNACE INFORMATION Model: ........Serial number: .
  • Page 14: Sequence Of Operation

    6 SEQUENCE OF OPERATION Table 1: Sequence of operation Thermostat to Control Mode Control Control Function Board 24 VAC Electric Heat only Continous Fan Fan ON at the selected continous fan CFM (Fan switch ON) Fan OFF Fan ON at 50% of the selected Heat CFM, 1st stage of Heat ON** Thermostat calls for 1st stage Heat 1st stage of Heat OFF, Fan OFF Fan ON at selected Heat CFM, 1st stage &...
  • Page 15 Thermostat to Control Mode Control Control Function Board 24 VAC Compressor ON, Fan ON after delays at selected Heat Pump CFM Thermostat calls for 1st stage Heat (Heat pump heating mode) Y/Y2 & G Compressor OFF, Fan OFF after selected Heat Pump delays Fan ON at selected Heat CFM, 1st stage &...
  • Page 16: Table

    7 TECHNICAL SPECIFICATIONS Table 2: Technical specifications(240V) RATING AND OFEAxx000-VV OFEAxx-000-1HVV PERFORMANCE Motor 1/2 HP / 240V Motor 1 HP / 240V Capacity Power, total @ 240V / 208V (Kw) 10 / 7.5 15 / 11.3 18 / 13.5 20 /15 23 / 17.3 25 / 18.8 27 / 20.3 30 / 22.5 Power, first stage @ 240V / 208V 5 / 3.8...
  • Page 17: Figure 15: Furnace Dimensions

    REVISIONS REV. DESCRIPTION DATE Figure 15: Furnace Dimensions 559mm 22" 25mm 1" SUPPLY 25mm ALIMENTATION 1" Identical on the 2 sides Identique sur les 2 cotés 559mm 22" 927mm 508mm x 508mm 36 1/2" 20" x 20" Identical on the 2 sides, the back and below.
  • Page 18: Table

    Table 3: Airflow tables UNIQUE Advantage ECM ½ HP motor COOLING OR HEAT PUMP HEATING MODE (WITH HP-EFF SELECTED AC / HP SIZE A/C size AC/HP CFM ADJUST AC/HP CFM ADJUST AC/HP CFM ADJUST Adjustment (TONS) BLACK wire position BLACK wire position BLACK wire position BLUE wire position (BLK) = (NOM)
  • Page 19: Table

    Table 4: Airflow tables UNIQUE Advantage ECM 1HP motor COOLING OR HEAT PUMP HEATING MODE (WITH HP-EFF SELECTED AC / HP SIZE A/C size AC/HP CFM ADJUST AC/HP CFM ADJUST AC/HP CFM ADJUST Adjustment (TONS) BLACK wire position BLACK wire position BLACK wire position BLUE wire position (BLK) = (NOM)
  • Page 20: Airflow Tables Unique Advantage Ecm ½ Hp Motor 17 Airflow Tables Unique Advantage Ecm 1Hp Motor 18 Venting Delays

    Table 5: Venting Delays ON & OFF DELAY FOR COOLING AND HEAT PUMP HEATING MODE ON / OFF DELAY Adjustment ON-Delay OFF-Delay WHITE wire position Time % "CFM" - Time 0 / 90 0 sec. 100% - 90 sec. 30 / 90 30 sec.
  • Page 21: Figure 16: Electrical Diagram, Unique Advantage Ecm

    Figure 16: Electrical diagram, U Advantage ECM NIQUE...
  • Page 22: Figure 17: Parts List, Advantage Ecm

    Figure 17: Parts list, Advantage ECM...
  • Page 23: Parts List, Advantage Ecm

    Table 6: Parts List, Advantage ECM Item Description Note 1 OFE-B04343-04 Left side panel assembly Includes insulation 2 OFE-B04344-02 Back panel assembly 3 OFE-B04343-02 Right side panel assembly Includes insulation 4 OFE-B04302-01 Top front panel 5 OFE-L01J006 Breaker 60 A 6 OFE-K03071-A Sequencer card assembly Card and plastic pins 7 OFE-B03531-03 Electronic card assembly...

This manual is also suitable for:

Advantage ofea 000-1hvv series

Table of Contents