Fimco HIGH-FLO HFP-24000-214 Owner's Manual

Fimco HIGH-FLO HFP-24000-214 Owner's Manual

12 volt, 2.4 gpm, 60 psi bypass diaphragm pump

Advertisement

Quick Links

12 Volt, 2.4 GPM, 60 PSI
Bypass Diaphragm Pump
Model: HFP-24000-214
(5281373/5151089)

Installation and Service Information

Fimco High-Flo High Performance pumps are designed to pump water and aqueous solutions of common pesticides. They are not
designed to pump petroleum products or other flammable materials. They are not designed to pump bleach solutions. Use of this
pump for petroleum products or bleach solutions will void the warranty. When pumping liquids other than water, the pump
should be flushed out with a cleaning solution, such as Fimco Tank Neutralizer & Cleaner, or clean water mixed with a good grade
dish soap after each use to prolong pump life.
This High-Flo High Performance pump is equipped with an internal bypass valve with a factory set pressure limit. When the system
pressure hits the limit, the internal valve will open and circulate fluid internally to relieve excess pressure. Operating the pump for
longer than 10 minutes in the bypass stage, discharge is closed, could damage the check valve. The motor will continue to run until
the pump is shut off with the manual switch located in the lead wire or the pump is disconnected from the power source.
High-Flo High Performance pumps are self-priming. Vertical prime will depend on the viscosity of the liquid and suction line size.
Minimum recommended suction line size is 3/8 inch. Make sure all hose clamps are tight before testing or spraying for the first
time. The installation of a 50 mesh strainer is recommended to prevent debris or other foreign material from entering the pump
and causing pump failure. The pump should be mounted in a dry and adequately ventilated area. The pump can be mounted hori-
zontally or vertically. If mounted vertically, the pump head should be down and the motor should be up. This pump has 3/8" fe-
male pipe threads at the inlet and outlet ports. Use 3/8" male pipe threaded fitting to connect to this pump. Use flexible hose or
tubing to connect to the inlet and outlet ports on the pump. This minimizes stress on the pump head. Never use rigid pipe connec-
tions. Do not compress the feet. Overtightening will reduce the ability to isolate vibration & noise.
Pump is rated at 2.4 GPM @ open flow.
Pump is designed to run off of the battery of your ATV, lawn tractor, or other vehicle with a 12V system. If using a stand alone
battery, use a deep cycle RV or marine battery.
The pump should be winterized before storage, by pumping a solution of RV antifreeze through it, and the entire plumbing system.
High-Flo High Performance Pumps are warranted against manufacturer or workmanship defects forTwo (2) years from date of
purchase for home owner usage and 90 days for commercial usage.
WARNING:
To reduce the risk of injury, the
user must read and understand the operator's
manual before using this product.
WARNING:
Cancer and Reproductive Harm.
www.P65Warnings.ca.gov
OWNER'S MANUAL
Retain a copy of receipt for your pump.
As it will be required to validate any warranty service.
See Page 6 for Warranty Information
www.fimcoindustries.com
1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD 57049
Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440
[5194687
(01/22)]
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HIGH-FLO HFP-24000-214 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fimco HIGH-FLO HFP-24000-214

  • Page 1 When pumping liquids other than water, the pump should be flushed out with a cleaning solution, such as Fimco Tank Neutralizer & Cleaner, or clean water mixed with a good grade dish soap after each use to prolong pump life.
  • Page 2 Always turn off power to pump and relieve pressure in the system before leaving pump unattended. After Spraying: Clean Pump and Sprayer. Using a tank neutralizer cleaner like Fimco Tank Cleaner and Neutralizer to thoroughly clean system. Dispose or Store chemicals properly as recommended by the chemical label.
  • Page 3 Drain and then refill half full, add the recommended amount of a good quality tank cleaner, such as FIMCO Tank Neutralizer and Cleaner. Turn pump on and circulate through system for 15 minutes and then spray out through handgun nozzle.
  • Page 4 Pump Model: 5281373 Available Replacement Parts Replacement Pump: 5151089 DON’T • • Clean and rinse your pump after each use with Fimco Tank Use to pump bleach. Neutralizer. • Use to pump petroleum products such as diesel fuel, gaso- •...
  • Page 5 Motor Running-BUT Little to No Pressure: Cleaning the Check Valve: If you’re experiencing little to no pressure or the pump is not priming and you’ve checked your filter screen and it’s clean, and you’ve gone through the other trouble shooting tips, you may need to clean the check valve.
  • Page 6 WHAT REMEDIES ARE AVAILABLE UNDER THIS LIMITED WARRANTY. If the conditions set forth above are fulfilled and the Equipment or any part thereof is found to be defective, Fimco shall, at its own cost, and at its option, either repair or replace the defective Equipment or part. Fimco will pay for shipping and handling fees to return the repaired or replacement Equipment or part to you.

This manual is also suitable for:

52813735151089

Table of Contents