Advertisement

Quick Links

User ManUal

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DETECT APEX LOCATOR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DENTSPLY DETECT APEX LOCATOR

  • Page 1 User ManUal...
  • Page 2: Table Of Contents

    Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1 .
  • Page 3: Introduction

    FOR DENTAL USE ONLY 3 . Warnings (See Contraindications) Introduction See above. • Only use the original charger. Congratulations on the purchase of Detect ™ 4 . Precautions The Detect device must be used with the manufacturer’s original accessories only. ™ In order to prevent infectious agent transmission it is highly recommended to use a rubber dam system during the endodontic procedure.
  • Page 4: Step-By-Step Instructions

    6 . step-By-step Instructions A. Content C. Replacement of the rechargeable battery Check the contents of the equipment before use: The battery compartment is located at the bottom of Detect and the cover is secured ™ by a screw. – one Detect apex locator – one charger ™...
  • Page 5: Getting Started

    D. Getting Started E. Searching for the Apex 1. Disconnect the charger from the device if connected. 1 . Coronal and Medial Zone 2. Connect the measurement cable and switch the device On – after a short logo Slowly introduce the file into the canal. The cursor on the tooth icon indicates the progression presentation, the main screen is displayed and the cursor on the tooth image will start of the file inside the canal.
  • Page 6 2) apical Zone F. Sound Adjustment The apical zone is divided into 10 segments graduated from 0.9 to 0.0 (apex) as visual Detect is equipped with a sonic indicator which enables monitoring of the progression of ™ information of file progression. the file within the canal. When the apex is reached, the cursor shows “APEX” and a solid tone is emitted. This function, in conjunction with the display of progression, enables working “blind” while still monitoring the progression of the file. BegInnIng oF aPICal Zone MIDDle oF aPICal Zone aPICal PosITIon...
  • Page 7 I. Maintenance of your Detect L. Standard Symbols ™ The device does not contain user serviceable parts. The service and repair should be On the device label appears standard symbols as follows: provided by factory trained service personnel only. Attention, consult Type BF applied part Class II Equipment After each use, all the objects that were in contact with infectious agents should be cleaned...
  • Page 8 ProCeDUre For lIP ClIP, hook anD Fork (ConT’) Operation Operating mode Warning Rinsing –Rinse the accessories manually with plenty of water Manual Cleaning –clean manually the –the hook mechanism has to be activated accessories with an during the cleaning process (press the push adequate brush, button several times) pre-soaked in a clean –no visible impurities should be observed on the pre-disinfectant solution accessories.
  • Page 9 Manufactured for: DENTSPLY Maillefer DENTSPLY International, Inc. 608 Rolling Hills Drive Johnson City, TN 37604 1-800-924-7393 1-800-924-7389 (fax) www.maillefer.dentsply.com Manufactured Under U.S. Patent #6,425,875. ©2010 DENTSPLY International, Inc. DETECTDFU05/10...

Table of Contents