AST P-GM+ User Manual

AST P-GM+ User Manual

Non-contact infrared pyrometers

Advertisement

Quick Links

Accurate Sensors Technologies
We measure accurate temperature in extreme conditions
AST P-GM+
Non-contact Infrared Pyrometers
USER MANUAL
AST - Accurate Sensors Technologies
Misgav Industrial Park, Misgav 20173, Israel
Tel: +972-4-9990025, Fax: +972-4-9990031
Email: info@accuratesensors.com
Web: www.accuratesensors.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P-GM+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AST P-GM+

  • Page 1 Accurate Sensors Technologies We measure accurate temperature in extreme conditions AST P-GM+ Non-contact Infrared Pyrometers USER MANUAL AST - Accurate Sensors Technologies Misgav Industrial Park, Misgav 20173, Israel Tel: +972-4-9990025, Fax: +972-4-9990031 Email: info@accuratesensors.com Web: www.accuratesensors.com...
  • Page 2: Table Of Contents

    Index 1. Chapter - 1 ........................General information 2. Chapter - 2 ........................Introduction 2.1 Application, range and working principle 3. Chapter - 3 ........................Technical specification 4. Chapter - 4 ........................Setting at the instrument 4.1 Operation 4.2 Adjustment parameters 5.
  • Page 3: Chapter - 1

    -20°C to +70°C. 1.1.6 Warranty AST P-GM+ instruments have a warranty of two years from the invoice date. AST will replace defective parts, which arises from design errors or manufacturing faults. In case, if pyrometer is opened, disassembled or modified then the guarantees will loss.
  • Page 4: Chapter - 2

    PC, parametrizing can also be done. AST P-GM+ has response time of 2 msec in triggering mode. It has USB 2.0 output. Emissivity, response time Peak Picker, Auto OFF Timing and Temperature Hold Time can be can be observed or adjusted through available optional software.
  • Page 5: Chapter - 3

    Chapter - 3 Technical Specifications Model P-GM+ Temperature Range 250°C….600°C Photo Detector Type InGaAs Spectral Range 1.6 µm Response Time 2 msec. Adjustable upto 10 sec. Repeatability 0.1% of reading in °C ±1°C Accuracy +/- 0.3% of the measured value ±1°C Ambient Temp.
  • Page 6: Chapter - 4

    Chapter - 4 Product Overview Optical Head USB Connector for Communication & Battery Charger Probe OLED Display Push Button for Power ON & data capture Back Cover...
  • Page 7: Setting At The Instrument

    Operation Before powering ON the pyrometer, make sure that the battery is charged up to some level. AST P-GM+ can be powered ON by pressing the trigger button for the first time at a single push. After power ON, the device starts an initializing routine for some seconds.
  • Page 8 4.4Adjustable parameters (Through PC Software) Emissivity : It is the relationship between the emissions of a real object and the emission of a black body radiation source at the same temperature. For a correct measurement it is necessary to adjust emissivity.
  • Page 9: Software Installation

    Chapter - 5 Software Installation The provided AST P-GM+ software offers possibilities to connect with your system shows recorded data for parameter setting, view offline data and to evaluate the measured data. 5.1 Installation Install the pyrometer software using the installation guide file on CD ROM.After installation of the software.
  • Page 10 A. 5.2.2Parameter Setting All user selectable device parameters can be set by using the software in the Panel "Parameter". A) Emissivity settings : The emissivity can be set by clicking on "Parameters” and select or type in the desired emissivity directly in the description field. The emissivity value will be transferred to pyrometer by hitting the "TAB"...
  • Page 11 No of Events Present This head shows the no of events recorded. Retrive Events By clicking on Retrive Events Button, the data which are recorded in pyrometer shows on the screen with time, date, Temperature & Emissivity.
  • Page 12 Save Events By clicking on the save events, File will be stored in .xls format. Clear Memory After clicking on Clear Memory button, the window appears with the box ask to save events or not before clear memory. If yes, record will be saved...