G Monitor Display
There are two monitoring modes, alarm associated (SPOT)
mode and alarm ignore (OFF) mode, depending on the
selection for MONITOR MODE in the ALARM SETUP menu.
Typical cases are described below for each setup.
Alarm Associated Mode
• The image of the alarmed input is displayed on the mul-
tiscreen monitor in single spot mode, interrupting what-
ever live, playback, single or multiple image previously
displayed. When a new alarm is received, the last acti-
vated input image will be displayed.
• The blinking camera title and "ALARM" indication on the
monitor will be alternately. For example, when an alarm
is received from CH1, "CH1 ALARM" will be displayed
on the monitor.
CAM1
CH1 ALARM
• When a camera signal loss has occurred, the monitor
display switches to a blackout screen with the channel
number indicated, for example, "CH 1 LOSS".
CAM1
CH1 LOSS
Alarm Ignore Mode
• The images being displayed will remain on the monitor
screen when an alarm arises, but the "ALARM" status
indication will appear.
The following outputs for each channel will be enabled or
disabled depending on the settings made in the TRIGGER
ACTION SETUP menu.
• The following will be disabled when OFF is selected for
the channel.
• The following will be enabled when REC&ALM is select-
ed for the channel.
• Only alarm recording will be enabled when REC is
selected for the channel.
G Alarm Recording
The recorder starts alarm recording with the preset rate and
picture quality, if applicable. See ALARM RECORDING for
details.
G Alarm Buzzer
The buzzer sounds when an alarm is input, if applicable.