1
User's Manual
Cautions for safety
Be sure to read cautions before use for correct use.
The specifications and exterior sizes described in this manual
may be subject to change for improving product capacity.
Safety Precautions
1.This product was not manufactured as a safety device. Therefore, in case
of using it as a controller such as for a device that may cause casualty,
serious damage to peripheral devices, and tremendous loss of property,
be sure to attach double safety devices.
2.Do not wire or inspect or repair while power is on.
3.In case of supplying power, be sure to check a terminal number for connection.
4.This device should not be dissembled, processed, improved, or repaired.
Caution
• Before the installation of this device, understand fully how to use, safety regulations
or warnings, and be sure to use within specified related specifications or related
capacities.
• Do not wire or install it for a motor or solenoid with great inductive load.
• During the extension of a sensor, use a shielding wire, and do not make it unnecessarily
longer.
• Do not use the same power supply or any part that generates arc during closing or
opening directly near the power supply.
• A power line should be far apart from a high-tension wire, and the device should not be
installed in a place containing much water, oil, or dust.
• Do not install it in a place under direct light or exposed to rain.
• Do not install it in a place with strong magnetism or noise or vibration or impact.
• Put it far apart from a place that may release strongly alkaline or strongly acidic substance,
and use an independent pipe.
• Do not spray water directly on it for cleaning in case of installing it in the kitchen.
• Do not install it in a place where temperature/humidity exceeds rating.
• Take caution not to break a sensor wire or make any scratch.
• A sensor wire should be away from a signal line, power, and load line, and use an
independent pipe.
• In case of dissembling or modifying this product voluntarily, it may not be applied with
warranty service.
• A
mark on the terminal circuit diagram is a safety mark as warning or caution.
• Do not use it near any device (harmonics welder, harmonics, harmonics radio, and
large capacity SCR controller) that generates strong harmonics noise.
• In case of using it with any other method than one designated by a manufacturer,
injury or loss of properties may occur.
• As it is not a toy, keep out of the reach of children.
• Installation must be done by a relevant professional or a qualified person.
• Our company shall not be responsible for any damage caused by failing to observe
the contents specified in the above warnings or cautions or by the fault of a consumer.
Danger
Caution, risk of electric shock
Electric Shock - Do not contact with AC terminal during current carrying.
This may cause electric shock.
Input power must be blocked when checking input power.
Models
Model
Range
Sensor
Dimension
Function
Temp./Humi.
Temp./
Humi. control
FOX-301 series can be changed as followings :
※
Sensor HCPV-220NH is convertible
Sensor for temperature : FS-200N(NTC 10K)
Sensor for humidity : HCPV-220H
Converted temperature range : Upto -55.0 C ~ 99.9 C
°
°
humidity range
: Upto 10~95%
Name of each parts
Temp. measured value display(red)
Humi. meausred value display(green)
Humi. output display
Dehumi. output display
Set value(UP) key
Humi. mode changing key
Set value(DOWN) key
Temp. mode changing key
Heating output display
Cooling output display
Set value display
Measured value display
Power
Wiring terminal
Output : 250VAC 2A
Please make sure to use the power relay or a suitable magnet .
FOX-301AR1
yellow
green
black
white
red
control
RS485
Sensor
Standard type
(Integral unit)
yellow green
Temp./Humi.sensor
Product exterior dimension
Tempeature
sensor
Humidity
sensor
<Front>
<Wall-hanging>
<Panel type>
Temperature
Setting for temperature
Temp./Humi. sensor
Cooling temperature
setting
Temp./Humi.sensor
series
Heating temperature
Customized
setting
(Extended sensor)
Setting for temperature programs
press for more than 5 sec.
delay time
min.
Unit
deviation
temperature
corrected
present
temperature
<Panel hole>
applied
applied
present temperature
communication
address
communication
speed
Need help?
Do you have a question about the FOX-301 Series and is the answer not in the manual?
Questions and answers