Nibe ClimaCool CoolLogic Touch Installation, Operation & Maintenance Manual
Nibe ClimaCool CoolLogic Touch Installation, Operation & Maintenance Manual

Nibe ClimaCool CoolLogic Touch Installation, Operation & Maintenance Manual

Hide thumbs Also See for ClimaCool CoolLogic Touch:

Advertisement

Quick Links

CoolLogic Touch
Installation, Operation & Maintenance Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ClimaCool CoolLogic Touch and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nibe ClimaCool CoolLogic Touch

  • Page 1 CoolLogic Touch Installation, Operation & Maintenance Manual...
  • Page 2: Table Of Contents

    Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 CoolLogic Touch Control System Network Setup .
  • Page 3: Introduction

    Introduction General Description WARNING/ADVERTISSEMENT The CoolLogic Touch Control System provides leaving Disconnect power supply(ies) Debrancher avant d’entreprendre chilled and hot water liquid temperature control algorithms before servicing. Refer servicing le dépannage de l’appareil. which maintain precise temperature control for cooling, to qualified service personnel.
  • Page 4: Communications Wiring

    Communications Wiring CoolLogic Touch Control System Wiring Field Connections to the Modules The CoolLogic Touch Control Panel (see Figure 1) connects A separate 115 volt power supply is required to power the to the modules using the embedded ARC156 networking CoolLogic Touch Control Panel.
  • Page 5 Communications Wiring Avoiding Noise ARC 156 Wiring Specifications Avoid running communication wires or sensor input wires The table below lists the specifications for ARC156 wiring. next to AC power wires or the controller’s relay output The wire jacket and UL temperature rating specifications wires.
  • Page 6: Configuration - Coollogic Touch Control System

    Configuration – CoolLogic Touch Control System Configuring the CoolLogic Touch Controller CoolLogic Touch Control System Operator Interface Turn off the CoolLogic Touch Controller’s power The CoolLogic Touch Control System offers an easy-to-use Using the rotary switches, set the CoolLogic Touch operator interface touch screen (Figure 5) which includes a Controller’s address .
  • Page 7 Configuration – CoolLogic Touch Control System Starting the Chiller Setup Menu When power is first applied to the CoolLogic Touch Control Chiller system operation is determined by the values assigned Panel, a 45 second initialization period will occur. The display to the system variables, as predominantly found in the Setup will show the home screen (Figure 7) .
  • Page 8 Configuration – CoolLogic Touch Control System Alarm Menu To Power Down Chiller Bank Up to 100 of the most recent occurrences stored with date Locate CoolLogic Touch Panel for the particular bank to and time . Access to this log is available through the keypad . be disabled .
  • Page 9 Configuration – CoolLogic Touch Control System Recommended for Extended Bank Shutdown Remove the command for “Remote Chiller Enable” using the BAS System or hard wire connection . Turn off the switch on the front of the CoolLogic Touch Control Panel Leave main power ON to the CoolLogic Touch Controller .
  • Page 10: Standard Alarm Functions

    Standard Alarm Functions High Pressure Cutout High Leaving Condenser Water Temperature - This requires resetting both the module’s manual reset high Above 138° F pressure control switch and the CoolLogic Touch Control The CoolLogic Touch Control Panel will auto reset after the Panel’s software reset to resume operation.
  • Page 11: Standard Features

    Standard Features Chilled Water Flow Sensor menus . If the chiller is operating and it receives a chilled water reset command, the leaving chilled water temperature setting The CoolLogic Touch Control Panel has an input for a will be allowed to ramp toward the new setting at a rate of differential pressure sensor, which measures and displays 2°F every seven minutes .
  • Page 12 Standard Features Chilled Water Temperature Sensor Connections LonWorks LonTalk Communications ® Chilled water temperature monitoring (entering and leaving) Interface Option is a standard feature of the CoolLogic Touch Control System . It The CoolLogic Touch Control Panel provides an optional is accomplished by using a factory supplied pair of sensors and LonTalk communication interface between the chiller and...
  • Page 13: Startup And Warranty Form

    Startup and Warranty Form CoolLogic CoolLogic Touch Module Size Selector Controller Page 1 of 3 Project Name: Start-Up Date: Chiller # Bank # System Setup Module 1 Size ......... . Module 2 Size .
  • Page 14 Startup and Warranty Form Page 2 of 3 Refrigeration Temp and Press Chiller # Bank # Cool PID Setup Discharge Pressure Available ....Suction Pressure Available .
  • Page 15 Startup and Warranty Form Page 3 of 3 Chiller # Bank # Router MAC Address IP Network # ..... __ __ __ __ __ MS/TP Network # .
  • Page 16: Coollogic Touch Screen Menu Hierarchy

    CoolLogic Touch Screen Menu Hierarchy User Access – Home Screen (Example Only) Tap any module to CoolLogic Controller see its respective Level Configuration Previous information and status Module Level Configuration Modules populate screen as they are added Status (4) Alarm Menu (3) System Setup (2) Service Menu (7) CoolLogic Touch Menu...
  • Page 17: Status User Access

    Status User Access Home Module Level Module Info Configuration CoolLogic Controller Status Level Configuration System Setup Alarms Service Menu www.climacoolcorp.com...
  • Page 18: Setup User Access

    Setup User Access System Setup Cool & Heat Free Cooling Setup Setpoints Remote Demand Controller Config Limiting Configuration www.climacoolcorp.com...
  • Page 19: Service User Access

    Service User Access Service Menu Configure DPT Calibrate & Lock Device Temps Configure Low Alarm Lockout Ambient Heat Reset Reset Comp Diagnostic Manual Run times & Cycles Mode (FN7) www.climacoolcorp.com...
  • Page 20: Coollogic Touch Control System Network Setup

    CoolLogic Touch Control System Network Setup Connection Type Device Instance of CoolLogic Touch Controller The default CONNECTION TYPE for the BACnet over The device instance number for the CoolLogic Touch ETHERNET to the WEB PORTAL is a CAT5 Cable via an Controller is 516800.
  • Page 21: Control Panel With I/O Pro 8/12U

    Appendix A Physical Hardwire Inputs and Outputs The CoolLogic Touch Control Panel with I/O Pro 8/12U - Quick Reference Guide Input Points Input # Description Input Type Bank Chilled Water Outlet Temperature AI - Thermistor/RTD Bank Chilled Water Entering Temperature AI - Thermistor/RTD Bank Condenser Water Outlet Temperature AI - Thermistor/RTD...
  • Page 22: Panel With I/O Flex 6126, Models Ucw/H/R

    Appendix B The CoolLogic Touch Module Controller with I/O Flex 6126 - Quick Reference Guide Models UCW/H/R Input Points Input # Description Input Type Compressor 1 Suction Refrigerant Pressure AI - Pressure Transducer (o-5VDC) Compressor 2 Suction Refrigerant Pressure AI - Pressure Transducer (o-5VDC) Compressor 1 Discharge Refrigerant Pressure AI - Pressure Transducer (o-5VDC) Compressor 2 Discharge Refrigerant Pressure...
  • Page 23: Panel With I/O Flex 6126, Model Uca

    Appendix C The CoolLogic Touch Module Controller with I/O Flex 6126 - Quick Reference Sheet Model UCA Input Points Input # Description Input Type Compressor 1 Suction Refrigerant Pressure AI - Pressure Transducer (o-5VDC) Compressor 2 Suction Refrigerant Pressure AI - Pressure Transducer (o-5VDC) Compressor 1 Discharge Refrigerant Pressure AI - Pressure Transducer (o-5VDC) Compressor 2 Discharge Refrigerant Pressure...
  • Page 24 Wiring Diagram – CoolLogic Touch Control Panel www.climacoolcorp.com...
  • Page 25 Wiring Diagram – CoolLogic Touch Control Panel www.climacoolcorp.com...
  • Page 26: Wiring Diagrams

    Wiring Diagram – Single Unit Module Control www.climacoolcorp.com...
  • Page 27 Wiring Diagram – Voltage/Phase Monitor www.climacoolcorp.com...
  • Page 28: Warranty Certificate

    Warranty Certificate www.climacoolcorp.com...
  • Page 29 Notes www.climacoolcorp.com...
  • Page 30 15 S . Virginia Oklahoma City, OK 73106 Phone: 405.815.3000 Fax: 405.815.3052 www .climacoolcorp .com ClimaCool works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein.

Table of Contents