Advertisement

Quick Links

IBX100 RCU CONTROL UNIT
4679000
4679003
INSTALLATION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IBX100 and is the answer not in the manual?

Questions and answers

Summary of Contents for ARAG IBX100

  • Page 1 IBX100 RCU CONTROL UNIT 4679000 4679003 INSTALLATION...
  • Page 2: Table Of Contents

    This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for future reference; ARAG reserves the right to modify the specifications and instructions regarding the product at any time and without prior notice.
  • Page 3: Risks And Protections Before Assembly

    • In case of voltaic arc welding, remove connectors from device and disconnect the power cables. • Only use ARAG genuine spare parts and accessories. PACKAGE CONTENT 1 Control unit 2 Instruction manual (DVD-ROM) 3 Connector closing cap Wiring must be ordered separately (Ref. to ARAG general catalog) Fig. 1...
  • Page 4: Position On Farming Machine

    LINE 2 Fig. 2 Legend of connection cables: NUM. TYPE COD. 1A Monitor / IBX100 / battery for TOWED MACHINE( 4679000.151 1B Monitor / IBX100 / battery for SELF-PROPELLED MACHINE( Cable connecting DELTA 80 - Sensors / control uniti ●...
  • Page 5 INSTALLATION > > > 5.1 System recommended composition The length of the last descent of cables with Tab. 1 - CONNECTION CABLES even number of Seletron is 1 meter; The length of the last descent of cables with odd number of Seletron is 0.5 meter The cables for single and twin SELETRON feature 2 outputs per joint.
  • Page 6 Fig. 3 Legend of connection cables: NUM. TYPE COD. 1A Monitor / IBX100 / battery for TOWED MACHINE ( 4679000.150 1B Monitor / IBX100 / battery for SELF-PROPELLED MACHINE( Cable connecting DELTA 80 - Sensors / control unit (G + P) Control unit IBX100 Sprayer - battery 4679000.103...
  • Page 7: Control Unit Fixing

    For any reference to the system configuration read par. 5.1. Respect the mounting direction of the control units, as specified in Fig. 4 (connectors shall be facing down) Fasten the IBX100 using 4 bolts installed in the relevant slots ( , Fig. 4).
  • Page 8: Wiring Connections

    SYSTEM WITH SECTION VALVES Hydraulic unit Seletron - Line 2 SYSTEM WITH SELETRON Seletron - Line 1 Monitor + power supply + IBX100 Hydraulic (hydraulic controls) Fig. 6 IBX100 HYDRAULIC CONNECTION POINTS Hydraulic unit IBX100 Sprayer (water controls) Fig. 7...
  • Page 9: Ibx100 - Monitor Connection

    Monitor / IBX100 / Power supply Monitor / IBX100 / Power supply There are different cables available for switch box connection (ARAG general catalog). Alternatively, connect the joystick (Fig. 11). The hydraulic or section valve controls are managed via switch box; alternatively, connect the joystick.
  • Page 10 Monitor / IBX100 / Power supply IBX100 / Power supply There are different cables available for switch box connection (ARAG general catalog). Alternatively, connect the joystick (Fig. 15). The hydraulic or section valve controls are managed via switch box; alternatively, connect...
  • Page 11 > > > 5.4 IBX100 - MONITOR connection HARNESS CONNECTION FOR SPRAYER MODE CONNECTION Monitor / Auxiliary functions / IBX100 / Power supply Fig. 16 COLLEGAMENTO JOYSTICK Connect the joystick to the relevant connector on the power supply harness. Fig. 17...
  • Page 12: Wiring Connections

    • Use of unsuitable cables not provided by ARAG automatically voids the warranty. • ARAG is not liable for damages to the equipment, persons or animals caused by failure to observe the above instructions. General precautions for a correct harness position •...
  • Page 13: Securing The Seletron Cables

    USED ON LONGER BOOMS. IBX100 main control valve, flowmeter and pressure sensor must be installed in the front section of the machine; if needed, ONLY the sensors may be moved to a different position and connected using the extensions listed in the catalogue. Never use an extension for any other components unless you have so agreed with the ARAG Assistance Center.
  • Page 14 HARNESSES, ETC.) COME INTO CONTACT WITH MOVING PARTS AT ANY TIME WHEN THE SYSTEM IS IN USE (INSTALLATION, COMMISSIONING, USE AND SHUTDOWN OF THE FARMING MACHINE). ARAG will not be held responsible for any damage to the system, people, animals or objects caused by failure to follow the guidelines outlined above.
  • Page 15: Control Unit Valve Connection - System With Section Valves

    • Use ARAG valves: use of unsuitable valves not provided by ARAG automatically voids the warranty. ARAG is not liable for damage to the equipment, persons or animals caused by failure to observe the above instructions. • All valve connectors must be provided with seals before being connected (Fig. 31).
  • Page 16: Sensor Connection

    • level sensor • filling flowmeter; • RPM sensor. All ARAG sensors use the same type of connector. Connect the sensor connector to the relevant harness; make sure it is correctly fitted and push it until locking it. Fig. 33...
  • Page 17: Power Supply Connection

    To avoid short circuits, do not connect the power cables to battery before the installation is completed Before powering up the IBX100 make sure the tractor battery voltage is as specified (12 VDC). Connect the power cable directly to the battery using the suitable eyelets.
  • Page 18: Maintenance / Diagnostics / Repairs

    MAINTENANCE / DIAGNOSTICS / REPAIRS MAINTENANCE / DIAGNOSTICS / REPAIRS KEY TO LED STATUS COLORE verde giallo rosso - consistent flashing = constant flashing - periodical flashing = set of several flashes separated by a pause Upon start, the control unit switches the LEDs on in the following sequence: Switch on 1 green LED - 2 yellow LED - 3 red LED Sequence overall duration: 2 seconds.
  • Page 19: Technical Data

    Dispose of the system in compliance with the established legislation in the country of use. GUARANTEE TERMS 1. ARAG s.r.l. guarantees this apparatus for a period of 360 days (1 year) from the date of sale to the client user (date of the goods delivery note).
  • Page 20 Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com 42048 RUBIERA (Reggio Emilia) - ITALY Via Palladio, 5/A Tel. +39 0522 622011 Fax +39 0522 628944 http://www.aragnet.com...

This manual is also suitable for:

46790004679003

Table of Contents