Operating Instructions Submodule MSM-1-R-CKS2-FLX-... Contents About this document ..................... 3 1.1. Scope ............................3 1.1.1. Notes on older product versions ..................3 1.2. Target group ..........................3 1.3. Key to symbols ..........................3 1.4. Supplementary documents ......................3 Correct use ......................4 Description of the safety function ................5 Exclusion of liability and warranty .................
Always read all documents to gain a complete overview of safe installation, setup and use of the device. The documents can be downloaded from www.euchner.com. For this purpose enter the doc. no. or the order number for the device in the search box.
The submodule MSM-1-R-CKS2-FLX-... may be combined only with suitable MLI modules (see Table 2: Combination options for modules with MLI technology). On the impermissible use of other keys or the modification of system components, EUCHNER provides no warranty for safe function.
Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating instructions are always available during mounting, setup and servicing. For this reason you should archive a printed copy of the operating instructions. You can download the operating instructions from www.euchner.com. MAN20001527-02-01/23 (translation of the original operating instructions)
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 6. Function Submodule Key A-FLX-K-0A-RD-168921 168921 MSM-1-R-CKS2-FLX-… 1 key per packaging unit A-FLX-K-0A CKS2 LED Key identification Illuminated key Key A-FLX-K-0B-RD-… adapter 168963 168963 168963 Several keys per packaging unit, with identical key code and different key iden- A-FLX-K-0B A-FLX-K-0B A-FLX-K-0B...
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 7. Mounting Important! Mounting must be performed only by authorized personnel. Ì The submodule MSM-1-R-CKS2-FLX-... can be used only in base units with MLI technology (see Table Ì 2: Combination options for modules with MLI technology on page 4). Submodule mounting is described in the operating instructions for the respective base unit.
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... Setup DANGER Danger to life due to tampering. Unused keys must be rendered unusable or protected against unauthorized access to prevent by- Ì passing the safety function. If master keys or replacement keys are used, the operating organization must take suitable organi- Ì...
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 10.2. Teaching-in a new key Important! Only the key version with which the device was configured can be taught-in. Reconfiguration is not Ì possible. The teach-in operation may be performed only if the device functions flawlessly. The LED flashes Ì...
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 12. Status and error messages 12.1. LED indicator Color CKS2 Illuminated key adapter red, green, yellow (externally controlled) CKS2 LED Illuminated key adapter Important! If you do not find the displayed device status in the following tables, this indicates an internal device fault.
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 12.2. Status messages LED indicator SM_FI_S3 SM_I_S3_E Status Device is ready for operation. No key inserted. green slowly Key inserted. green Device is in teach-in standby (see chapter 10.2. Teaching-in a new key on page 9). white ¨...
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 12.3. Error messages Acknowledging errors LED indicator Error Troubleshooting Teach-in errors Once bit SM_O_Jx has been set for the teach-in input, the No key detected during teach-in standby. key must be inserted within 3 minutes. ¨ Key removed from the key adapter prior to the end of the Repeat teach-in operation.
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 12.4. Acknowledging error messages Depending on the error type, the error message can be acknowledged by briefly removing the key or by a reset. After a reset, the overall system must be restarted. For this purpose, disconnect the bus module MBM from the power supply for a few seconds.
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 14. Technical data 14.1. Technical data for submodule MSM-1-R-CKS2-FLX-... NOTICE If a data sheet is included with the product, the information on the data sheet applies. Parameter Value Housing material Fiber glass reinforced plastic Dimensions See dimension drawing data sheet Weight 0.1 kg net Ambient temperature...
MSM-1-R-CKS2 Series MSM-1-R-CKS2BP Series MSM-1-R-CKS2BR Series MSM-1-K-CKS2 Series MSM-1-K-CKS2BP Series MSM-1-K-CKS2BR Series Responsible Party – U.S. Contact Information EUCHNER USA Inc. 1860 Jarvis Avenue Elk Grove Village, Illinois 60007 +1 315 701-0315 info(at)euchner-usa.com http://www.euchner-usa.com MAN20001527-02-01/23 (translation of the original operating instructions)
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... 14.3. Technical data for key A-FLX-K-… Parameter Value Unit min. typ. max. Housing material ABS plastic Dimensions 40 x 31 x 5 Weight 0.004 Ambient temperature °C Degree of protection IP65/IP67 Power supply Inductive via key adapter 14.3.1.
Loss of the safety function because of damage to the device. In case of damage, the affected module must be replaced completely. Only accessories or spare parts that can be ordered from EUCHNER may be replaced. Regular inspection of the following is necessary to ensure trouble-free long-term operation: Check the secure mounting of the devices and the connections Ì...
Page 18
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... (translation of the original operating instructions) MAN20001527-02-01/23...
Page 19
Operating Instructions Submodule MSM-1-R-CKS2-FLX-... MAN20001527-02-01/23 (translation of the original operating instructions)