H3C CR16000-F Installation Manual page 163

Hide thumbs Also See for CR16000-F:
Table of Contents

Advertisement

Table 1 Card slot arrangement
MPU
installation
Model
location
CR16006-F
CR16010H-F
(four switching
fabric modules)
Two
uppermost
card slots on
the front
panel
CR16010H-FA
CR16010H-F
(five switching
fabric modules)
CR16010-F (one
fan tray)
CR16010-F (two
fan trays)
Two middle
card slots on
the front
panel
CR16014-F
CR16018-F (four
Two
switching fabric
lowermost
modules)
card slots on
Card slot numbering
As shown in
Figure
1, the card slots
are numbered as follows:
On the front panel, the card
slots are numbered 0 to 5 from
top to bottom.
On the rear panel, the card
slots are numbered 6 to 9 from
left to right.
The card slots are numbered as
follows:
On the front panel, the card
slots are numbered 0 to 9 from
top to bottom.
On the rear panel, the card
slots are numbered 10 to 13
from left to right.
The card slots are numbered as
follows:
On the front panel, the card
slots are numbered 0 to 9 from
top to bottom.
On the rear panel, the card
slots are numbered 10 to 14
from left to right.
The card slots are numbered as
follows:
On the front panel, the card
slots are numbered 0 to 9 from
top to bottom.
On the rear panel, the card
slots are numbered 10 to 14
from left to right.
The card slots are numbered as
follows:
On the front panel, the card
slots are numbered 0 to 9 from
left to right.
On the rear panel, the card
slots are numbered 10 to 13
from top to bottom.
As shown in
Figure
2, the card slots
are numbered as follows:
On the front panel, the card
slots are numbered 0 to 13
from top to bottom.
On the rear panel, the card
slots are numbered 14 to 17
from left to right.
As shown in
Figure
3, the card slots
are numbered as follows:
On the front panel, the card
4
Card slot arrangement
MPU slots: slots 0 and 1
Service module slots:
slots 2 to 5
Switching fabric module
slots: slots 6 to 9
MPU slots: slots 0 and 1
Service module slots:
slots 2 to 9
Switching fabric module
slots: slots 10 to 13
MPU slots: slots 0 and 1
Service module slots:
slots 2 to 9
Switching fabric module
slots: slots 10 to 14
MPU slots: slots 0 and 1
Service module slots:
slots 2 to 9
Switching fabric module
slots: slots 10 to 14
MPU slots: slots 4 and 5
Service module slots:
slots 0 to 3 and slots 6 to
9
Switching fabric module
slots: slots 10 to 13
MPU slots: slots 6 and 7
Service module slots:
slots 0 to 5 and slots 8 to
13
Switching fabric module
slots: slots 14 to 17
MPU slots: slots 16 and
17
Service module slots:

Advertisement