Installation, Relocation, Storage, and Connection
Do not attempt to lift the Device Expansion Unit only by yourself.
The Device Expansion Unit weighs max. 20 kg (depending on its
hardware configuration). Always get more than one persons or use
the lifter to install, disassembly, or carry the Device Expansion Unit.
Carrying out these actions only by yourself may strain your back or
drop the chassis to cause personal injury or damage of surrounding
devices. Lift the Device Expansion Unit by firmly holding its bottom
with other person.
Do not install the Device Expansion Unit in any place other than
specified.
Do not install the Device Expansion Unit in the following places or any
place other than specified in this User's Guide. Failure to follow this
instruction may cause a fire.
・a dusty place
・a place exposed to direct sunlight
・a humid place such as near a boiler ・an unstable place
Do not install the Device Expansion Unit on rack with leaving
covers removed.
Do not install the Device Expansion Unit on a rack with the cover being
removed. Failure to follow this instruction not only may decrease the
cooling effect in the Device Expansion Unit and result in some
malfunction, but may also allow dusts to enter the Device Expansion
Unit and result in a fire or electric shock.
Be careful not to get your fingers caught in the rails or other
components.
When mounting/removing the device onto/from the rack, be careful to
avoid getting your fingers caught in the rails or cutting your fingers on
the rails.
Do not attempt to connect or disconnect the interface cable while
the power cord is plugged into an outlet.
Make sure to power off the Device Expansion Unit and unplug the
power cord from the power outlet before connecting/disconnecting the
interface cable. If the Device Expansion Unit is powered off but its
power cord is plugged to a power source, touching the cable may
cause an electric shock or a fire resulted from a short circuit. Also,
connect/disconnect the interface cable after turning off the power of
the destination.
Do not use any unauthorized interface cable.
Use only interface cables provided by NEC and locate a proper
device and a proper connector before connecting a cable. Using an
authorized cable or connecting a cable to an improper destination
may cause a short circuit, resulting in a fire.
Also, observe the following notes on using and connecting an interface
cable.
Do not use any damaged cable connector. Before connecting an
interface cable, confirm that any cable connector is not damaged and
any connector pin is not bent or dirt.
・Do not step on the cable.
・Do not place any object on the cable.
・Do not use the Device Expansion Unit with loose cable connections.
・Do not use the Device Expansion Unit with loose interface cable
connections. After connecting the interface cable, secure it with a
screwdriver or equivalent. To disconnect the interface cable, release the
secured part and hold the connector and pull it straight out.
Do not use the equipment in the place where corrosive gases exist.
Do not install the Device Expansion Unit in a place subject to corrosive
gases including sulfur dioxide, hydrogen sulfide, nitrogen dioxide,
chlorine, ammonia, and ozone. Do not install the Device Expansion Unit
in an environment that contains dusts or chemicals that accelerate
corrosion such as sodium chloride, sulfur, and conductive materials.
Failure to follow this warning may cause the wires on the printed wiring
board to short circuits, leading to fire. If you have any questions,
contact the store where you purchased the product or a maintenance
service company.
Do not close the ventilation hole.
Do not close fan or the front ventilation hole at the back of the Device
Expansion Unit. Otherwise, its internal temperature will rise to cause
malfunctions or a fire.
Do not apply any weight on the Device Expansion Unit when it is
extended from the rack.
Do not apply any weight on the Device Expansion Unit when it is
extended from the rack. Doing so may cause the frames to be bent,
which makes it impossible to be mounted on the rack. It also may
cause the Device Expansion Unit to fall, resulting in personal injury.
Do not work in the state installed to the rack.
Do not work in the state installed to the rack. Failure to follow this
warning may cause an electric shock. Please work after removing from
the rack.
Notes on Installing and Accessing the Rack Cabinet
Do not carry or install the rack only by a single person.
More than one person is required to carry or install the rack. Failure
to follow this instruction may cause the rack fall to result in personal
injury and/or breakage of surrounding devices. In particular, a high
rack is unstable if it is not fixed by stabilizers. More than one person
must always carry or install the rack while they support it.
Do not install with the load weight distributed unevenly
To avoid unevenly distributing the load of the rack and device, install a
stabilizer or connect multiple racks to distribute the weight. Otherwise,
the rack may fall, resulting in personal injury.
Do not install components on the rack only by yourself.
Two or more people are required to install the rack components such
as the door or rails. When installing the door, make sure that both
upper and lower hinge pins are held in place. Failure to follow this
instruction not only may cause some parts to fall but may also be
broken and result in personal injury. .
Do not pull out a device from the rack if the rack is unstable.
Always pull out a device from the rack in the state that the rack is
made stable (by the installation of stabilizers or earthquake-resistant
construction).
Failure to follow this instruction may cause the rack to fall out and
result in personal injury.
When wiring for the rack, be sure not to exceed the rating of the
power supply.
To prevent burns, fires, and device damages, the power supplied to
the power supply in the rack shall not exceed the rating load of the
power branch circuit. Contact the local power company for the
requirements on the wiring and installation of electric facilities.
Do not extend more than one device out of the rack.
Extending multiple devices from the rack may cause the rack to fall,
resulting in personal injury. Extend only one device at one time.
Elevated Operating Ambient
If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than
room ambient. Therefore, consideration should be given to installing
the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow
Installation of the equipment in a rack should be such that the amount
of air flow required for safe operation of the equipment is not
compromised.
Mechanical Loading
Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when
addressing this concern.
Reliable Earthing
Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than
direct connections to the branch circuit (e.g., use of power strips).
During Operation
Do not touch the Device Expansion Unit during thunderstorms.
Do not touch any part of the Device Expansion Unit, including the
cables, when a thunderstorm is approaching. Also, do not connect or
disconnect any devices. There may be a risk of electric shock from
lightning strike.
Do not place any object on top of the Device Expansion Unit.
The Device Expansion Unit may fall and cause property damage to the
surroundings.
Do not pull out or remove the Device Expansion Unit from the
rack.
Do not pull out or remove the device from the rack while the device is
running. In addition to causing equipment to not function properly,
separating the device from the rack may result in personal injury.
Do not use a cellular phone or pager around the Device
Expansion Unit.
Turn off the cellular phone or pager around the Device Expansion Unit.
Radio interference may cause malfunctions of the Device Expansion
Unit.
Keep any animal (pet) away from the Device Expansion Unit.
Pet's discharges or fur may enter the Device Expansion Unit and cause
a fire or electric shock.
1. Verify the packed contents
Verify the packed contents with the part list given below and ensure that all the
components and parts are present. Also, check that each item is undamaged. If a
component or part is missing or damaged, contact your dealer.
2. Installation Procedure  NEC Rack/Third Vendor Rack 
(1) Remove the inner rails from the rack rails, attach the inner rails to the Device Expansion Unit
with a M4 Millimeter Screws.
(2) Loosen the eight screws fixing the slide bracket of each of the outer rails.
This is required to have the length of the outer rail be the same as the depth of the rack (or the distance
between the front and rear supports). If the screws are loosened, you can slide the slide bracket.
If the depth of the rack is not enough, remove the two screws at the tip to extend the slide bracket.
※Attach the screws which removed to the position of the figure.
Inner rail
Rack rail
(3) Locate the outer rails on the frames of the rack.
(4) Fix the each of the outer rails by using M5 Millimeter screws(two at each of the front and rear, or four in
total) and washers(two at each of the front and rear, or four in total).
(5) Fasten the screws loosened in step 1 to fix the slide bracket.
(6) Install another outer rail on the rack in the same way as described in steps 1 to 4 above.
(7) Two or more workers hold the unit securely to mount it on the rack.
Two round stamps
(located at 5U position)
Stamp
Narrower distance
between angle holes
3. Install a 5.25-inch devices in the Device Expansion Unit in the procedure below.
・To install a 5.25-inch device in DEVICE1, use the latching rails (2) installed in the Device Expansion Unit
(1) To install 5.25-inch devices in DEVICE2 - DEVICE4,
remove the respective device bay covers.
(2) Install latching rails on the 5.25-inch device to be
installed in the Device Expansion Unit.
(3) Install the 5.25-inch device into the device bay.
Push the device until a click occurs
User's guide in attached CD describe detailed explanation.
© NEC Corporation 2015 No copying or modifying without permission of NEC Corporation.
The contents of this document may be changed without notice.
Parts name
1
Device Expansion Unit
2
Latching Rail
3
Rack Rail
4
M5 Millimeter Screw
5
M4 Millimeter Screw
6
Washer
7
Startup Guide(This manual)
CD (USER'S GUIDE )
8
Outer rail
Slide bracket
Plastic guide
Bearing rail
Inner rail
Release lever