Advertisement

Quick Links

XENOLUX 180
Light Source
V.2019.04.01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XENOLUX 180 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ecleris XENOLUX 180

  • Page 1 XENOLUX 180 Light Source V.2019.04.01...
  • Page 2 ECLERIS USA 11801 NW 100th Rd Suite 17 Medley, FL 33178 Phone: +1 786 483 7490 CMC Medical Devices & Drugs S.L. C/ Horacio Lengo Nº18, CP29006, Málaga, Spain Ph. +34951214054 Email: info@cmcmedicaldevices.com...
  • Page 3: Table Of Contents

    INDEX INDEX ................................ 3 INTRODUCTION ............................4 DESCRIPTION ............................5 FRONT PANEL ..................... 5 REAR PANEL ......................6 TECHNICAL SPECIFICATIONS ......................7 SIMBOLS DESCRIPTION ..................8 COMPONENTS ............................9 INSTALLATION ............................10 REVISION AND OPERATION........................ 11 REVISION ......................11 MAINTENANCE ............................13 CLEANING ......................
  • Page 4: Introduction

    INTRODUCTION XENOLUX 180 light source has a Xenon arc lamp designed to be used in all ECLERIS microscope and colposcope models as well as in therapeutic and diagnostic procedures. This light source has a connection for endocamera, video output and universal adapter for those fiber optic models most widely distributed in the market.
  • Page 5: Description

    DESCRIPTION FRONT PANEL On/Off switch Diaphragm control Camera connector (video input) Universal fiberoptic cable connector INMANUUIN182...
  • Page 6: Rear Panel

    REAR PANEL Power supply voltage selector switch (110/220V)) Power supply cable connector with fuse holder S-Video Output (SVHS) Composite Video Output (CVBS) EclerisEndodigiConnector (Image and video capture) and other peripheral devices* 10 Ventilationgrids *Standard output (Normally-Open) to remotely operate other image capture devices such as Video Printers.
  • Page 7: Technical Specifications

    Built-in revolving turret with multiple adapters VIDEO OUTPUT Composite Video (CVBS) (1 Vpp/75 Ω), BNC S-Video (Y/C), Jack mini-DIN ECLERIS ENDODIGI CONNECTOR Mono Jack 3.5 mm DIMENSIONS 150 X 330 X 230 MM (width x depth x high) WEIGHT 5.8 KG SERVICE CONDITIONS 10 - 40 ºC...
  • Page 8: Simbols Description

    SIMBOLS DESCRIPTION Attention! Read the related documentation. Alternate current Protect against water Fragile CE Mark Identificación del fabricante (Nombre, Dirección) B Type...
  • Page 9: Components

    COMPONENTS XENOLUX 180 light source includes the following components. It is recommended to identify and check their existence before proceeding with the installation.  MainUnit  PowerSupply Cable  User’s Manual INMANUUIN182...
  • Page 10: Installation

    Thoroughly follow the instructions included in this section. Unpacktheequipmentcarefully. In case of using the XENOLUX 180 as an endoscopic light source, place it on a solid and flat surface. Rotate the universal adapter until the corresponding connector is aligned with the light output.
  • Page 11: Revision And Operation

    REVISION AND OPERATION REVISION Once installation is over and before turning the XENOLUX 180 on, please go through the following check list: • Verify that the electrical power has its grounding connection in perfect conditions and that it makes perfect contact with the equipment.
  • Page 12 You may begin the procedure after turning the XENOLUX 180 on, by pressing the on/off switch. The Xenon Lamp takes 2 seconds to turn on after the XENOLUX 180 is ON. Use the diaphragm control to regulate lighting intensity. Once the procedure is over, turn the XENOLUX 180 off in order to maximize the lamp useful life.
  • Page 13: Maintenance

    MAINTENANCE In order to keep an optimum operation of the XENOLUX 180 it is recommended to perform the following procedures: • Periodic cleaning of all exterior components. • Connections inspection. • Annual technical inspection of the equipment. To perform any revision or maintenance work, contact your local distributor or the closest ECLERIS office.
  • Page 14: Electrical Connections

    • Faulty connection between the cable and the plug. • Oxide corrosion in connection pins FUSE CHANGE To avoid time losses due to downtime of the XENOLUX 180, it is recommended to have a spare fuse. 1 Disconnect the power supply cable from the electrical power and the equipment.
  • Page 15 Lamp fastening screw Disconnect the lamp power supply connector. Remove the lamp holder screw and take away the defective lamp. Place the new 180W Xenon lamp in the lamp holder as shown in the figures (code part: XBO R180/45C). Fix the lamp by adjusting the lamp holder screw. Connect the Xenon lamp power supply connector (male) to the light source female connector.
  • Page 16: Troubleshooting

    TROUBLESHOOTING The following table indicates the most common problems and their quick solutions. Please consult this table for any difficulty you may encounter. PROBLEM PROBABLE CAUSE ACTION The equipment It is not connected to the Connect the power supply cable does not turn on electrical power to the electrical power...
  • Page 17: Warnings

    It is important to read this manual thoroughly before using the XENOLUX 180. ECLERIS shall not be liable for the damages that may occur if the equipment is not used according to these instructions and following the criteria mentioned herein below: •...
  • Page 18: Maintenance Card

    • Poor care and maintenance of the equipment or. • Repair or manipulation by unauthorized personal. …any material or personal damage were caused to third parties, ECLERIS, the manufacturer and the supplier of the equipment, shall not assume any responsibility for such damages.
  • Page 19 This card shall only be completed by the authorized person from the company responsible for the maintenance, repair and modification of the device. We recommend keeping it updated for a quicker and more efficient service. INMANUUIN182...
  • Page 20: Technical Service

    Product’s serial number. • Problem’s description. The XENOLUX 180 shall be sent in its original packing so that it is not damaged during transportation. ECLERIS shall not be liable for damages that may occur during transportation, caused by deficient packaging.
  • Page 21: Warranty

    (1) year as from the date of purchase invoice. ECLERIS shall not be liable for any damage caused to/by the XENOLUX 180 due to incorrect use, negligence, cleaning or incorrect storage. Any repairs made by personnel not authorized by ECLERIS will void this warranty.