Lippert TI-452 Adjustment

Pneumatic outswing door actuator

Advertisement

Quick Links

Purpose

This document outlines the procedures for making outswing door linkage adjustments.

Safety

Read and understand all instructions before installing or operating this product. Adhere to all safety labels.
This manual provides general instructions. Many variables can change the circumstances of the instructions,
i.e., the degree of difficulty, operation and ability of the individual performing the instructions. This
manual cannot begin to plot out instructions for every possibility, but provides the general instructions,
as necessary, for effectively interfacing with the device, product or system. Failure to correctly follow the
provided instructions may result in death, serious personal injury, severe product and/or property damage,
including voiding of the Lippert limited warranty.
Always wear eye protection when performing service, maintenance or installation procedures.
Other safety equipment to consider would be hearing protection, gloves and possibly a full face

Resources Required

• Straight blade screwdriver
7/16
" Wrench
9/16
" Wrench
• 8mm Wrench
NOTE: An angled open-end wrench or pliers may be required to rotate the linkage rods to complete
adjustments due to the confined working area.
Rev: 02.28.2023
PNEUMATIC OUTSWING DOOR ACTUATOR
shield, depending on the nature of the task.
Moving parts can pinch, cut or crush. Keep clear and use caution.
ADJUSTMENT
DOORS
Page 1
CCD-0007326

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TI-452 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lippert TI-452

  • Page 1 Failure to correctly follow the provided instructions may result in death, serious personal injury, severe product and/or property damage, including voiding of the Lippert limited warranty. Always wear eye protection when performing service, maintenance or installation procedures.
  • Page 2 PNEUMATIC OUTSWING DOOR ACTUATOR ADJUSTMENT DOORS Procedure Outswing Door Linkage Adjustments Preliminary outswing door linkage adjustment. A. Manually position door leaves to a fully opened position. B. Remove the actuator assembly's cover (Fig. 1A). Using a screwdriver, back out the three slotted fasteners (Fig. 1B) securing the cover. II.
  • Page 3 PNEUMATIC OUTSWING DOOR ACTUATOR ADJUSTMENT DOORS C. Using an 9/16" wrench, loosen the jam nuts (Fig. 2A) on the two linkage rods (Fig. 2B) connected to the teeter arm assembly (Fig. 2C). NOTE: Linkage rods have "-24 UNF right hand threads on the ends adjacent to the teeter arm assembly "-24 UNF left hand threads on the ends adjacent to the door pivot arm assemblies.
  • Page 4 PNEUMATIC OUTSWING DOOR ACTUATOR ADJUSTMENT DOORS Adjust air pressure regulator to obtain consistent, proper opening of the door. A. Pull the adjustment knob (Fig. 3A) out on the air pressure regulator (Fig. 3B) to unlock the control. Fig. 3 Rotate the adjustment knob (Fig. 4A) clockwise to increase pressure and door speed (Fig. 4). II.
  • Page 5 PNEUMATIC OUTSWING DOOR ACTUATOR ADJUSTMENT DOORS B. Push the adjustment knob in (Fig. 5A) to lock the adjustment. C. Evaluate operation of the bi-fold door's opening action to make sure the following elements are met: Bi-fold door fully opens. II. Bi-fold door opens smoothly—not jerky or noisy. III.
  • Page 6 PNEUMATIC OUTSWING DOOR ACTUATOR ADJUSTMENT DOORS Fig. 6 Air Cylinder Decrease Increase Page 6 Rev: 02.28.2023 CCD-0007326...
  • Page 7 As a supplier of a broad array of highly-engineered components in the recreation and transportation product markets, safety, education and customer satisfaction are our primary concerns. Should you have any questions, please do not hesitate to contact us at 432-LIPPERT (432-547-7378) or by email at customerservice@lci1.com.