Woodward DTSC-200A Installation Manual

Woodward DTSC-200A Installation Manual

Ats controller
Hide thumbs Also See for DTSC-200A:

Advertisement

37482A
DTSC-200A
ATS Controller
Installation
Software Version 2.0xxx
Beta-Version Manual 37482A_1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DTSC-200A and is the answer not in the manual?

Questions and answers

Summary of Contents for Woodward DTSC-200A

  • Page 1 37482A DTSC-200A ATS Controller Installation Software Version 2.0xxx Beta-Version Manual 37482A_1...
  • Page 2 Provides other helpful information that does not fall under the warning or caution categories. Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and reliable. However, Woodward assumes no responsibility unless otherwise expressly undertaken.
  • Page 3: Table Of Contents

    Panel Cutout ............................7 Installation............................8 4. W ....................9 HAPTER IRING IAGRAM 5. C ....................11 HAPTER ONNECTIONS Power Supply ............................12 Interfaces ............................16 RS-485 Modbus RTU Slave ....................16 CAN Bus Interfaces (FlexCAN) ....................17 6. T .................... 19 HAPTER ECHNICAL © Woodward Page 3/20...
  • Page 4 Table 1-1: Manual - overview ................................5 Table 5-1: Conversion chart - wire size.............................11 Table 5-19: RS-485 Modbus interface - terminal assignment ......................16 Table 5-20: CAN bus interface - terminal assignment ........................17 Table 5-21: Maximum CAN bus length ............................18 Page 4/20 © Woodward...
  • Page 5: Chapter 1. General Information

    Manual 37482A DTSC-200 - ATS Controller Chapter 1. General Information Type English German DTSC-200A this manual  DTSC-200A - Installation 37939 DTSC-200A - Configuration in work 37940 DTSC-200A - Operation in work 37941 DTSC-200A - Application in work 37942 DTSC-200A - Interfaces...
  • Page 6: Chapter 2. Electrostatic Discharge Awareness

    CAUTION To prevent damage to electronic components caused by improper handling, read and observe the pre- cautions in Woodward manual 82715, Guide for Handling and Protection of Electronic Controls, Printed Circuit Boards, and Modules. Page 6/20 © Woodward...
  • Page 7: Chapter 3. Housing

    Manual 37482A DTSC-200 - ATS Controller Chapter 3. Housing Panel Cutout ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ Figure 3-1: Housing - panel-board cutout © Woodward Page 7/20...
  • Page 8: Installation

    (2). Over tightening of these screws may result in the clamp inserts or the housing breaking. Do not exceed the recommended tighten- ing torque of 0.1 Nm (0.9 pound-force inches). Reattach terminals Reattach the wire connection terminal strip (1) and secure them with the side screws. Page 8/20 © Woodward...
  • Page 9: Chapter 4. Wiring Diagram

    Manual 37482A DTSC-200 - ATS Controller Chapter 4. Wiring Diagram © Woodward Page 9/20...
  • Page 10: Figure 4-1: Wiring Diagram

    Relay [R08] isolated Power supply [R08] Command: Open from source 1 position 8 to 35 Vdc to neutral position Reverse polarity protected *1 configurable via LogicsManager Subject to technical modifications DTSC-200A Diagram Figure 4-1: Wiring diagram Page 10/20 © Woodward...
  • Page 11: Chapter 5. Connections

    The following chart may be used to convert square millimeters [mm²] to AWG and vice versa: mm² mm² mm² mm² mm² mm² 0.05 0.38 600MCM 0.08 750MCM 0.14 0.75 300MCM 1000MCM 0.25 350MCM 0.34 500MCM Table 5-1: Conversion chart - wire size © Woodward Page 11/20...
  • Page 12: Power Supply

    Manual 37482A DTSC-200 - ATS Controller Power Supply ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ General Notes Page 12/20 © Woodward...
  • Page 13 Manual 37482A DTSC-200 - ATS Controller Terminals RS485 Ethernet Not used RS232 Not used Source 1 Source 2 Load current Voltage Voltage max.300VAC max.300VAC © Woodward Page 13/20...
  • Page 14 Outside connected to secondary coil of CT in L2 load (rated 5 A) Load current L3 1.5mm Outside connected to secondary coil of CT in L3 load (rated 5 A) Load current N 1.5mm Outside connected to secondary coil of current transformer (Rated 5 A) Not used Page 14/20 © Woodward...
  • Page 15 Digital input 11 1.0mm Free purposes digital input Digital input 12 1.0mm Free purposes digital input Not used NOTE Woodward recommends to fuse-protect all lines according to their rated load (rated current). Wiring proposal RS232 Ethernet microSD Not used Device Not used...
  • Page 16: Interfaces

    Table 5-2: RS-485 Modbus interface - terminal assignment Half-Duplex with Modbus on RS-485   Figure 5-2: RS-485 Modbus - connection for half-duplex operation NOTE Please note that the DTSC must be configured for half- duplex configuration (refer to parameter 3173). Page 16/20 © Woodward...
  • Page 17: Can Bus Interfaces (Flexcan)

    Please note that the CAN bus must be terminated with a resistor, which corresponds to the impedance of the cable (e.g. 120 Ohms, 1/4 W) at both ends. The termination resistor is connected between CAN-H and CAN-L. Termination Termination Transistor Transistor 120Ohm 120Ohm Figure 5-5: Interfaces - CAN bus – termination © Woodward Page 17/20...
  • Page 18: Table 5-21: Maximum Can Bus Length

    • The configured baud rate is too high for wiring length • The CAN bus cable is co-routed with power cables Woodward recommends the use of twisted-pair cables for the CAN bus (i.e.: Lappkabel Unitronic LIYCY (TP) 2×2×0.25, UNITRONIC-Bus LD 2×2×0.22).
  • Page 19: Chapter 6. Technical Data

    Manual 37482A DTSC-200 - ATS Controller Chapter 6. Technical Data © Woodward Page 19/20...
  • Page 20 Phone +49 (0) 711 789 54-510 • Fax +49 (0) 711 789 54-101 stgt-info@woodward.com Homepage http://www.woodward.com Woodward has company-owned plants, subsidiaries, and branches, as well as authorized distributors and other authorized service and sales facilities throughout the world. Complete address/phone/fax/e-mail information for all locations is available on our website (www.woodward.com).

Table of Contents