NBR
Giriş Basıncı 0,5 bar)
n gazlar
GR70-GR40 GAS REGULATOR
afından özelleştirilir.
Basıncı 1 bar)
n gazlar
afından özelleştirilir.
ü (Max. IGiriş Basıncı 1 bar)
n gazlar
afından özelleştirilir.
USER MANUAL
PLEASE READ THE INSTRUCTIONS BEFORE USE!
K 607
GR 20
GR 30
GR 60
SEPTEMBER 2022
GF 10
GR 20
GR 30
/SMSTORK
/sms-tork
www.smstork.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the GR70 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tork GR70

  • Page 1 Diyafram ğı GR 20 GF 10 Giriş Basıncı 0,5 bar) n gazlar GR70-GR40 GAS REGULATOR afından özelleştirilir. USER MANUAL GR 30 GR 20 Basıncı 1 bar) n gazlar afından özelleştirilir. GR 60 GR 30 /SMSTORK /sms-tork www.smstork.com ü (Max. IGiriş Basıncı 1 bar)
  • Page 2 1 bar and they also have a safety membrane that will prevent the gas flow to the environment in case of rupture of the main membrane. ı dikkate alınarak üretici tarafından özelleştirilir. SMS-TORK Endüstriyel Otomasyon Ürünleri San. Tic. Ltd. Şti. lık...
  • Page 3 Doğalgaz Regülatörü (Max. Giriş Basıncı 0,5 bar) pan, bütan, şehir gazı, hava, agresif olmayan gazlar minyum Figure-1 GR 70 Model DN 25 Nominal Diameter TORK Filtered Gas Regulator with Safety Shutdown Product Tree C / +50°C mbar www.smstork.com teri uygulamaları dikkate alınarak üretici tarafından özelleştirilir.
  • Page 4 Compensation Diaphragm Screw Seals Compensation Diaphragm Screw Ring Funnel Screw Seals Blowback Tube O-ring Diaphragm Lower Disc O-ring Figure-2 GR 40 Model DN 25 Nominal Diameter TORK Filtered Gas Regulator Product Tree SMS-TORK Endüstriyel Otomasyon Ürünleri San. Tic. Ltd. Şti.
  • Page 5 Funnel Fixing Screw Flange Screws Bottom Cap Screws Anti Dust Tube Tap O-ring Regulation Screw Washer for Spring Setting Spring Filter Figure-4 GR 40 Model DN 32 - DN 40 -DN 50 Nominal Diameter TORK Filtered Gas Regulator Product Tree www.smstork.com...
  • Page 6 It is mounted in front of the regulation organs in the regulator gas lines to control the pressure. TORK brand regulators can provide the technical features required by the directive as a device within the scope of the 3G and 3D class of the gas group. (Equipment Group No. II, Category No. 3). Equipment Group No. II, Category No. 3 includes devices designed to provide normal level of protection.
  • Page 7 Spring Marking Input Pressure Connection Diameter Used Code Pressure Range (mbar) Color DN 25 - DN 32 White Maximum 1 Bar GY-26 5-30 DN 40 - DN 50 Table-4 GR40 and GR70 Model Regulators Safety Shut-Off Spring Selection Table www.smstork.com...
  • Page 8: Installation

    •After the assembly process is finished, check that you have not mounted the regulator upside down. •After installation, always check the gas tightness of the system. Example mounting shape and dimensions of the product are given below. Newtwork User SMS-TORK Endüstriyel Otomasyon Ürünleri San. Tic. Ltd. Şti.
  • Page 9 • Manually operated ball on-off valve • GR70 model safety shut-off gas regulator •TORK-DT Relief valve • Hand-operated ball valve with remote control handle Figure-5 GR 70 Model DN 25 Filtered Gas Regulator Assembly and Line Diagram Evacuation to the...
  • Page 10 A distance of at least 20 mm should be left between the body and the wall. FRO GR70 : DN25 DN32 - DN40 - DN50 FOR GR40 DN25 - DN32 - DN40 - DN50 SMS-TORK Endüstriyel Otomasyon Ürünleri San. Tic. Ltd. Şti.
  • Page 11 10354 5 - CALIBRATION, SELECTION, FLOW CONVERSION, OUTPUT PRESSURE AND REPLACEMENT GR70 MANUAL INSTALLATION: Our products come out of our factory in accordance with the user demand, with the safety pressures adjuste and the crown closed. Therefore, the installation process of our product on the customer line should be done as follows •Open the inlet valve slowly in 4 stages.
  • Page 12 Pull the crown out and set the regulator. In this case, verify that there is gas passage through the regulator (If you have trouble installing, consider the WARNING-2 explained below) Adjust the outlet pressure to the desired outlet pressure and finish the check. SMS-TORK Endüstriyel Otomasyon Ürünleri San. Tic. Ltd. Şti.
  • Page 13 WARNINGS: UYARI-1: For the item: Do not open the inlet ball valve quickly all at once. WARNING-2: For items 7 and 11: If you cannot install the assemble lever or if you have a problem closing the regulator at a value you do not want, try to loosen the regulation screw by turning it counterclockwise a little more. Do this delay until the assemble lever is installed.
  • Page 14 Otherwise, the values corresponding to the spring will increase and decrease irregularly; In such a case, loosen the springs enough to bring them to pressures that can meet the label values. SMS-TORK Endüstriyel Otomasyon Ürünleri San. Tic. Ltd. Şti.
  • Page 15 SELECTION: The choice of regulator 50k is important. While making the selection, these values should be known since the inlet pressure in the line, the desired outlet pressure, the safety closing pressure and the desired flow rate values will be used.
  • Page 16 P4 point is chosen because it is the smallest regulator among other points, with the value closest to 30 mbar. As it can be seen in Table-9 below, the Gr70 840 model for Gr70, the GR 40 04 model for GR 40, since the pressure loss value (approximately 16 mbar) is the closest to 30 mbar, this model is the most suitable model for us to give the flow rate we want.
  • Page 17 Flow Conversion The flow rates and flow capacity table above have been prepared for natural gas. In case our regulator is used in a gas other than natural gas, the flow rate of the said other gas is calculated according to the following flow conversion formula. •Ql:Q2xK •Q1: Gas Flow Rate (m3/h) •Q2: Flow Rate of Natural Gas (m3/h) selected in the capacity table...
  • Page 18: Maintenance And Repair

    6. MAINTENANCE AND REPAIR The maintenance, repair and cleaning works described below should only be carried out by authorized and certified technicians and authorized companies - services that have received approval from gas approval institutions. Definitely the end user should not do these operations. The user or unauthorized persons should never interfere with the product or even in case of any maintenance, malfunction or repair.
  • Page 19 7- ISSUES TO BE CONSIDERED AND WARNINGS It is strongly recommended to use our product in all gas lines so that the arguments in the system are not damaged. Especially in critical installation conditions (unprotected areas, poor ventilation, inadequate service and maintenance) or when flammable materials or dangerous devices are close to the regulator during normal operation;...
  • Page 20: Transport-Shipping

    8-USER ERRORS, FAULTS, CAUSES AND CONSEQUENCES When faced with malfunction situations, some examples of which are given below, the end user should definitely not intervene and should inform the authorized service or us. If a pressure higher than the pressure specified in the technical specifications section above comes to the regulator, the device may break down and there will be a constant high and unadjustable pressure transition on the outlet side.
  • Page 21: Warranty Certificate

    Factory : İMES O.S.B 2. Cd. No: 5 Çerkeşli OSB Mh. Dilovası - Kocaeli / Türkiye Product : Natural Gas Regulator Brand : TORK Model Delivery Date and Place : ......................Warranty Time : 2 years Maximum Repair Time : 20 working days Seller / Distributor : ......................
  • Page 22 NOTE SMS-TORK Endüstriyel Otomasyon Ürünleri San. Tic. Ltd. Şti.
  • Page 23 Çerkeşli OSB Mah. İmes-2 Cad. No 5 Dilovası Kocaeli TÜRKİYE /SMSTORK /SMSTORK /sms-tork /sms-tork www.smstork.com www.smstork.com...