Supplement; Technical Data - Vega VEGATOR 631 Ex Operating Instructions Manual

Signal conditioning instrument
Hide thumbs Also See for VEGATOR 631 Ex:
Table of Contents

Advertisement

9 Supplement

9.1 Technical data

General data
Series
Weight
Housing material
Socket material
Power supply
Operating voltage
Max. power consumption
Fuse
Supply area
-
Switching off possibility
-
Sensor input
Quantity
Response resistor
Parallel resistor for fault monitoring
Measuring circuit
Permissible line capacitance
Switching hysteresis
Adjustment elements
DIL switch block
Potentiometer
Control lamps in the front plate
Status indication operating voltage
-
Status indication fault signal
-
Status indication switching point control
-
Relay output
Quantity
Mode
Integration time
Contact
Contact material
VEGATOR 631 Ex • Signal conditioning instrument
Module unit with plug-in socket for mounting on
carrier rail 35 x 7.5 or 35 x 5 according to EN 50022
170 g (6 oz)
Noryl SE100, Lexan 920A
Noryl SE100, Noryl SE1 GFN3
20 ... 253 V AC, 50/60 Hz, 20 ... 72 V DC
1.5 W (1 ... 9 VA)
T 315 mA, 253 V
min. 35 A at 253 V AC or 125 V DC
1 x level detection or 1 x pump control (min./max.)
1 ... 200 kΩ adjustable
220 kΩ
max. 5 V eff., max. 1 mA
1 x 100 nF or 2 x 70 nF with min./max. control
15 %
for preadjustment of the integration time and mode
for switching point adjustment
Signal lamp green (LED)
Signal lamp red (LED)
Signal lamp yellow (LED)
1
A/B switch (A - max. detection or overfill protection,
B - min. detection or dry run protection)
500 ms
1 spdt for each output
AgNi, hard gold-plated
9 Supplement