Model No: ES15V-Q1(R)

3.Servicing Procedures

 

3.1 Remove the shell.

Before maintenance, the shell should be removed.
Firstly, take off the red and blue rings; then remove four screws, after that the shell can be
removed,
Attention to the snap joint, Don't break them.
 
 
 
 
Join screw
 
 
 
 
 
 
 
                                           
     
 
 
 
 
 
 
 
 
 
Unfold the shell                                                      Remove the foam cushion 
3.2 Change Temperature Controller (thermostat)
Temperature control Knob 
                                                                                                                 
 
 
 
 
 
 
 
 
 
1. Remove the knob
 
Issue 
Rev. 
2. Remove two screws and remove
temperature controller
Nov. 2014
A
Remove the screws