Download Print this page

Motorola DCT2000 Installation Manual page 47

Digital consumer terminal
Hide thumbs Also See for DCT2000:

Advertisement

Table B-3 lists the error codes:
E 00*
NO ERROR
E 01*
NOT CONNECTED
E 02
PWR CYCLE
E 03
DRAM
E 04
DPSRAM
E 07
ROM
E 08
RAM
E 09
BATTERY
E 10
SERIALNO
E 11
UNIT ADDRESS
E 12
POST
E 13
BOOT
E 14
STARTUP
E 15
TSI INVALID
E 16
FLASH BAD NUMBER
E 17
BAD PLATVAL
*E 00 and E 01 cannot be displayed while the DCT 2000 is off. The other errors will display on
the LEDs when the DCT 2000 is off.
Indicates normal condition after initialization
DCT 2000 did not receive a connect message
Init Error
DRAM error
DP-SRAM error
ROM verification failure
Faulty RAM, ROM, EEPROM, or POST failure
(this is a hardware failure)
Dead battery or memory has not been
initialized; occurs if battery fails to keep the
RAM alive during power-down; causes
DCT 2000 to be disconnected
Invalid serial number
Invalid unit address
POST failed
Sys_boot initialization failure
DCT 2000 system startup failure
TSI structure is corrupted
Bad flash number specified for
InitiateFlashPlatform
Bad platform validation step number
D i a g n o s t i c s
Not applicable
Send a connect message
Restore out-of-band signal
Box needs a Power Cycle to
recover
Not used at this time
Not used at this time
Power cycle box; if repetitive,
return for repair
Return DCT 2000 for repair
Return DCT 2000 for repair;
requires factory initialization
message
Not used at this time
Return DCT 2000 for repair;
requires a unit creation message
Not used at this time
Power cycle box; if repetitive,
return for repair
Power cycle box; if repetitive,
return for repair
Power cycle box; if repetitive,
return for repair
Error logged, ignore
Error logged, ignore