Advertisement

Quick Links

User Manual
X
Z7
ORAYA
X
ML-Z7
ORAYA
Edition: 1.2.1 / December 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XORAYA ML-Z7 and is the answer not in the manual?

Questions and answers

Summary of Contents for X2E XORAYA ML-Z7

  • Page 1 User Manual ORAYA ML-Z7 ORAYA Edition: 1.2.1 / December 2022...
  • Page 2 This user manual is copyrighted; all customary rights reserved. Reproduction of this manual, even in part, is only allowed with permission of X2E GmbH. Offenders shall be liable to pay compensation and may be subject to prosecution. All product names and trademarks used in this manual are the property of their respective owners.
  • Page 3: Table Of Contents

    About this user manual ................5 Validity of the user manual ............... 6 Representation conventions ..............7 Pictograms ....................7 X2E-Wiki ....................9 Safety and warranty ......................10 Intended use ................... 10 General safety instructions ..............12 Product liability ..................15 Terms of use ...................
  • Page 4 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ABLE OF CONTENTS Repair ....................185 Storage, transport and disposal ................186 Storage ....................186 Transport ....................186 Disposal ....................187 Appendix..........................188 Technical data ..................188 Datalogger pin assignments ..............189 Cable pin assignments ................196...
  • Page 5: Introduction

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA NTRODUCTION Introduction About this user manual  Read this user manual completely before using the datalogger for the first time.  Please consider this user manual as part of the product and make sure it is easily accessible.
  • Page 6: Validity Of The User Manual

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA NTRODUCTION Validity of the user manual This user manual applies to X2E’s X Z7 and X ML-Z7 dataloggers. ORAYA ORAYA The exact type specifications can be found on the nameplate. (➔ Identification) The following instructions are key to operate the datalogger and must be strictly observed under all circumstances.
  • Page 7: Representation Conventions

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA NTRODUCTION Representation conventions Representation Meaning  User-executed action <Instruction>  Instruction options <Instruction option 1>  <Instruction option 2>  Outcome of an action or a series thereof <Outcome> ▪ <Level 1a> Maximum two-level enumeration −...
  • Page 8 ANUAL Z7 | X ML-Z7 ORAYA ORAYA NTRODUCTION License information: This symbol indicates license information. License information contains either general information about licenses for the datalogger or indicates whether a license is required for a particular function. 1.4.1 Meaning of warnings Warnings are systematized according to the severity and probability of their occurrence.
  • Page 9: X2E-Wiki

    ▪ Latest firmware ▪ Latest license file ▪ For access details, please send an email stating your contact data to wiki@x2e.de. We will send you the appropriate access data. You may request your access details at any time if necessary.
  • Page 10: Safety And Warranty

    Upon measuring, safety regulations of the professional associations must be observed. Please contact an expert or the service of X2E GmbH when in doubt about the operation, safety, or connection of the datalogger. Intended use The datalogger is used for real-time acquisition of data communication in automotive bus systems.
  • Page 11 ANUAL Z7 | X ML-Z7 ORAYA ORAYA AFETY AND WARRANTY The datalogger and the additional device X ESU meet the requirements ORAYA of the EMC Directive of the European Union if the connecting cables supplied are used. You can find the declaration of conformity at the end of this user manual.
  • Page 12: General Safety Instructions

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA AFETY AND WARRANTY General safety instructions Electric shock caused by damage to components Any damage to the datalogger, power source or connection cable may cause an electric shock. DANGER  Switch on the datalogger only if all components appear undamaged.
  • Page 13 CAUTION  Never open the datalogger.  Contact X2E GmbH should maintenance and repairs be required. Device damage due to penetration of dust or liquids Dust or moisture inside the datalogger may cause abnormal behavior or destruction of the device.
  • Page 14 Safety defects due to incorrect accessories and spare parts Accessories and spare parts that have not been recommended by X2E GmbH negatively affect the safety, CAUTION functionality and precision of the datalogger. X2E GmbH shall assume no responsibility whatsoever or...
  • Page 15: Product Liability

    Terms of use If the installation of the datalogger in a vehicle is intended for operation on public roads, the user and the X2E GmbH must jointly perform a risk analysis beforehand. This analysis must consider the specific installation requirements and the valid factory standards at the user's site.
  • Page 16 ORAYA ORAYA AFETY AND WARRANTY In particular, X2E GmbH cannot guarantee that the software meets any user requirements, or that it is compatible with any programs the latter may have selected. Responsibility for program selection and the consequences of program use lie entirely with the user.
  • Page 17: Product Description

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA RODUCT DESCRIPTION Product description The X dataloggers are processor-controlled storage units, designed to ORAYA record data from several and different data sources simultaneously. These dataloggers are indeed unique in the automotive industry thanks to their central 100-ns timestamp on all interfaces.
  • Page 18: Identification

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA RODUCT DESCRIPTION Identification The bottom side of the datalogger bears a silver nameplate, which contains the following information: Device type Product variant ▪ Serial number Unique identification number for this datalogger ▪ Configuration First block: Product ID ▪...
  • Page 19: Scope Of Delivery

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA RODUCT DESCRIPTION Scope of delivery The following components are part of the delivery: Datalogger (X Z7 with impact protection) ▪ ORAYA Power supply cable ▪ Software ▪ User manual ▪ Cable set, depending on the interface configuration ▪...
  • Page 20: Connections And Controls

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA RODUCT DESCRIPTION Connections and controls The front side of the datalogger contains ports, buttons and LEDs for operation and elementary functions. The log interfaces are located on the back side of the datalogger. Front side ML-Z7 (here with BroadR-Reach add-on) Status LEDs of custom log interfaces...
  • Page 21 − Connect the drive and the firmware is automatically updated. Generating the supportfile ▪ − The supportfile is a set of files that you can send to X2E support to help solve technical issues. − Create the folder xoraya_supportfile on the USB flash drive.
  • Page 22 ANUAL Z7 | X ML-Z7 ORAYA ORAYA RODUCT DESCRIPTION General status LEDs (D): These LEDs indicate the operating status of the datalogger. Meaning Connect Connection between datalogger and X Suite is established ORAYA Info Datalogger is DHCP server Logging Logging in progress LED flashes as the logging stops, because the stopping process may take longer depending on the queue fill level Error...
  • Page 23 Press the default button with a pointed object for at least 3 seconds to reset all datalogger settings to factory defaults. Service port (H): In case of errors, this interface is used as a debugging interface by the X2E support team. USB device port (I):...
  • Page 24 ANUAL Z7 | X ML-Z7 ORAYA ORAYA RODUCT DESCRIPTION Trigger/wake button (J): The function of this button depends on the datalogger state. The following table describes these functions as delivered. Users can configure this behavior via the X Suite in the settings of the button interface. ORAYA (➔...
  • Page 25 ANUAL Z7 | X ML-Z7 ORAYA ORAYA RODUCT DESCRIPTION Back side ML-Z7 (configuration example: 7x LIN, 12x CAN, 1x Dual-FlexRay, 12x BroadR-Reach) Built-in log interfaces BroadR-Reach add-on Custom log interfaces Built-in log interfaces (N): The built-in interfaces of each X Z7 are: ORAYA 20x CAN (4x CAN FD by default)
  • Page 26 ANUAL Z7 | X ML-Z7 ORAYA ORAYA RODUCT DESCRIPTION Custom log interfaces (O): The slots can be variably equipped with up to three (X Z7) or five ORAYA ML-Z7) additional interfaces. ORAYA Slot and channel number of each hardware interface are also displayed in multiple locations of the X Suite tool Configuration: ORAYA...
  • Page 27: Commissioning

     Please contact X2E GmbH immediately should the delivery be incomplete or upon damaged components.  Do not put any defective component into operation. X2E GmbH can only accept your complaint and replace the affected component upon prompt notification. Keep original packaging Keep the original packaging and packing materials for later storage or further transport.
  • Page 28 Installation:  Close all open programs.  Use the X Suite setup wizard from the supplied data medium. ORAYA  Download the latest version of the X Suite from the X2E-Wiki. ORAYA (➔ X2E-Wiki)  Start the setup wizard xorayasuitesetup_<Version>.exe.
  • Page 29: Connecting The Datalogger To The Measuring Environment

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA OMMISSIONING Connecting the datalogger to the measuring environment This section describes how to connect the datalogger to the measuring environment. Device damage due to incorrect connection sequence The incorrect connection sequence can lead to abnormal behavior or destruction of the datalogger.
  • Page 30 ANUAL Z7 | X ML-Z7 ORAYA ORAYA OMMISSIONING 4.5.2 Power supply This chapter describes the default connection to a DC power supply via the supplied power cable. If you use the optionally available power cable with AC adapter, please note the specifications on the adapter label. Electric shock due to improper connection of the power supply Introducing the 4-mm plugs of the supplied power cable...
  • Page 31: Oraya

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA OMMISSIONING Continuous current of the DC power supply A 12 V DC power supply must deliver a continuous current of 1 A with 3 A peaks. Use a regulated power supply or a car battery and note the required voltage and current values.
  • Page 32: Connecting The Datalogger To The Pc

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA OMMISSIONING The datalogger is equipped with an intelligent energy management system that lowers power consumption to about 1 mA (at 12 V supply voltage) in sleep mode. The device goes into sleep mode via the following actions or under the following conditions: Pressing and holding the power button (K) for at least 2 seconds.
  • Page 33: Configuring Switches

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA OMMISSIONING Configuring switches  Configure the built-in terminators via the rotary switches on the back of the datalogger.  For the LIN interface, select between internal or external power supply via the toggle switch. 4.7.1 4x CAN Position...
  • Page 34: Xoraya Suite

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Suite ORAYA This chapter describes the operation of the graphical user interface Suite. ORAYA Starting  Perform all commissioning steps. (➔ Commissioning)  Start the X Suite by double-clicking the desktop icon. ORAYA ...
  • Page 35: Menu Bar

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Menu bar This section describes the five main menus of the menu bar. Individual menu commands are not available in every tool. 5.2.1 File Among other things, you can use the File menu to open and save files, or close the tool.
  • Page 36 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.2.2 Logger Among other things, you can use the Logger menu to connect or disconnect the datalogger with the X Suite. ORAYA Command Description Connect Connects the selected datalogger Disconnect Disconnects the active connection to the datalogger Offline-Logging >...
  • Page 37 Update software Opens the X2E-Wiki to download the current Suite version ORAYA Show logfile Displays a log file for the tool Supportfile Generates a set of files that you can send to X2E support to help solve technical issues...
  • Page 38: Status Bar

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.2.5 Language Use the Language menu to change the language of the X Suite. ORAYA Setting Description German (Deutsch) Changes the language of the X Suite to German ORAYA English (Englisch) Changes the language of the X Suite to English ORAYA...
  • Page 39: Connecting And Disconnecting The Datalogger

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Connecting and disconnecting the datalogger The datalogger is connected and disconnected in the same way regardless of the X Suite tool. This section shows the process for the ORAYA Configuration tool as an example. 5.4.1 Connecting the datalogger Display available loggers...
  • Page 40 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Icons and text colors indicate the status of the datalogger: and name Network error, the datalogger is located on a different subnet and name black Disconnected datalogger and name Another user is connected to the datalogger and name blue You are connected to the datalogger...
  • Page 41 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.4.3 Favorites You access the favorites list via Display settings button in the Configuration, Online-Logging Hdd-Download tools. Refresh the device list Devices in the network Add currently connected device to Add selected device to favorites favorites Add a device to favorites manually Remove device from favorite list...
  • Page 42: Configuration

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE The symbols in the columns Scan Ping display the current reachability of the dataloggers in the list. Ping reaches beyond subnet boundaries. Meaning of the symbols: reachable not reachable Configuration This tool allows the configuration of the datalogger and its interfaces. ...
  • Page 43 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Release connection to logger Display settings Start Hdd logging Save configuration file Save changed configuration permanently Categories The tree structure on the left side of the window displays system settings, available interfaces and signals at the highest level. Expand the tree at the desired position and to the desired depth to access the sub-items.
  • Page 44 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE You can view the properties sorted either alphabetically or by category. Properties that cannot be modified by the user are greyed out. Configuration changes can be saved temporarily or permanently. Save temporarily: ...
  • Page 45 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.5.1 System configuration System settings are configured via properties stored on the datalogger. These properties fall under various categories: Main Settings ▪ Network ▪ Hard Disk ▪ Snapshot ▪ Versions ▪ Profile ▪...
  • Page 46 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default Name Freely selectable name of the datalogger <DataloggerType> -<SerialNumber> Comment Current system time, internally with a precision of 100 ns Also used as a timestamp during logging System Time Internally used property for the system time Automatically Time period after which the datalogger...
  • Page 47 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE System Settings > Network: Open MAC-IP assignments...
  • Page 48 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default dynamic assigned Activate DHCP IP-Address <DHCP-Server> Datalogger DHCP mode On: DHCP server Off: DHCP client IP Address IP address assigned to the datalogger if: 10.104.2.21 <DHCP-Server> ▪ fixed IP-Address ▪...
  • Page 49 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DHCP server mode is intended for direct connections to PCs. You can bind MAC addresses of up to five PCs to IP addresses. Type them in manually or double-click in a row of the table that contains the addresses of the PCs in the network.
  • Page 50 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE System Settings > Hard Disk: Compression method Activate ESU* Activate internal storage medium Remove ESU safely* * Only with connected X ORAYA These settings and displays refer to the currently active storage medium, represented by the blue background color.
  • Page 51 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default Overwrite Control the datalogger behavior if the storage medium is full On: Oldest session or measurement is overwritten Off: Recording is terminated Autostart Immediate recording after switching on the datalogger or after disconnecting with the X Suite ORAYA...
  • Page 52 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE System Settings > Snapshot: Snapshots can be created during the measurement to track particularly interesting time periods. The moment you raise the corresponding trigger, all data received for a user-definable time before and after this moment, are stored in an additional snapshot measurement.
  • Page 53 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default Trigger Pre-time Leading time of the snapshot for the default-queue (Default-queue) (in ms) Trigger Post-time Trailing time of the snapshot for the default-queue (Default-queue) (in ms) Trigger Pre-time Leading time of the snapshot for the stream-queue (Stream-queue)* (in ms)
  • Page 54 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE System Settings > Profile: You can save different datalogger configurations using profiles. The following names are reserved for special profiles: active the permanently saved configuration, which is ▪ loaded when the datalogger starts default the factory default configuration ▪...
  • Page 55 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Load default profile:  Press the default button for at least 3 seconds. Protect active profile:  Enter a Password.  Click Activate password protection (1).  In the main toolbar, click Save changed configuration permanently.
  • Page 56 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE System Settings > Export: You can save the export settings and output formats for the Hdd-Download tool on the datalogger itself. This way, the settings are centrally defined and do not depend on the PC used for downloading later. Upload client settings onto the Delete client settings from the logger...
  • Page 57 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE System Settings > DLN: Set up a Distributed Logging Network, consisting of data sink (master) and one or multiple probes. For further information, see the quick manual for the X µT-Z7 probe. ORAYA...
  • Page 58 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE System Settings > Versions: All properties in this category are immutable and purely informative. Among other things, this displays version numbers for various datalogger components, as well as additionally activated licenses.
  • Page 59 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.5.2 Interface configuration Interface settings are configured via properties stored on the datalogger. These properties fall under various categories: Settings ▪ Filter ▪ Trigger ▪ Routing ▪ Other ▪ Advanced ▪ Interface or channel selection: ...
  • Page 60 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Interfaces:  Double-click a row in the table to jump directly to the corresponding interface or to the corresponding channel. Reducing power consumption of the datalogger To reduce the datalogger power consumption, disable all channels unneeded.
  • Page 61 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE CAN: 4 CAN channels are always FD-capable. By default, the FD-specific settings are missing on the remaining channels. CANFD_4PLUS_# For each of these licenses, the number of CAN-FD- capable channels is increased by 4. Check in category Versions of system settings to verify...
  • Page 62 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default Enable Turn on logging for this channel CAN FD standard On: ISO 11898-1 Off: original standard by Bosch Alias Freely selectable channel name can# Bus ID Additional ID for subsequent evaluation Baudrate Transfer rate (in bit/s) 500 k...
  • Page 63 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE CAN > Trigger: Number of bytes for the trigger Number of bytes for the response 8-byte blocks of the trigger Byte values of the response...
  • Page 64 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE The following check boxes affect the IDs of the specified CAN messages in this category: Extended frame Use 29-bit ID instead of 11-bit ID ▪ Can FD Activate CAN FD mode ▪...
  • Page 65 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Configure trigger responses:  Select the check box Send as response following CAN message.  Specify the ID of the CAN message that is sent as response to a trigger.  Select the check boxes Extended Frame, Can FD...
  • Page 66 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE CAN > Routing: Here, you configure the routing of messages received on other CAN channels via the currently selected channel. The payload is not changed while the IDs of source and target message can differ. Add routing Save routing Delete routing...
  • Page 67 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE CAN > Other: Here, you specify if the datalogger sends general system statistics and interface statistics as CAN messages during data recording. These CAN messages contain signals, which hold the specific values. General system statistics are, for example: RAM queue fill level ▪...
  • Page 68 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE The user-defined Offset within the 29-bit ID is displayed in green. This offset applies to each generated ID. The rest of the ID in orange is reserved and is automatically adjusted for each interface channel by the software. Click the button to open the generated messages and signals as a DBC file in a text editor and to save them for later analysis.
  • Page 69 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE FlexRay: FlexRay > Settings: Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name flexray# Bus ID Additional ID for subsequent evaluation Channel Selection, which one of both bus channels is used Values: A, B Use Busspec Load configuration template provided by the vehicle...
  • Page 70 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE LIN: LIN > Settings: Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name lin# Bus ID Additional ID for subsequent evaluation Baudrate Transfer rate (in bit/s) 19200 Values: 20000, 19200, 9600, 4800, 2400 Use Busspec...
  • Page 71 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE LIN > Trigger: Configure triggers:  Select the check box Enable Trigger from following LIN message.  Under Id, specify the ID of the LIN message that raises a trigger. (➔ Changing the numbering system) ...
  • Page 72 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE RS-232:...
  • Page 73 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default Protocol Raw, GNLog Enable Turn on logging for this channel Alias Freely selectable channel name rs232_# or gnlog# or DLT# Bus ID Additional ID for subsequent evaluation Use Busspec Load configuration template provided by the vehicle manufacturer Debug level**...
  • Page 74 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE PSI5: PSI5 > Common Settings: Setting Description Default Sync pulse Synchronization pulse period period not 0: Applies to all active channels on this slot 0: Value defined by the used operation mode Enable Turn on logging for this channel...
  • Page 75 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE PSI5 > Settings: Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name Bus ID Additional ID for subsequent evaluation Sync pulse period* (Only changeable in common settings) Operation mode PSI5 operation mode P10P_500_3L...
  • Page 76 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Pre-defined operation modes: Communi- Error Operation mode Payload Cycle Slots Bit rate cation detection A8P_250_1L Asynch. 8 Bit Parity 250 µs 125 kBit/s A10P_250_1L Asynch. 10 Bit Parity 250 µs 125 kBit/s A16CRC_500_1L Asynch.
  • Page 77 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Analog: Analog > Common Settings: Setting Description Default Sample Rate Samples per second Applies to all channels of the interface Enable Turn on logging for this channel...
  • Page 78 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Analog > Settings: Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name analog# Bus ID Additional ID for subsequent evaluation Use Busspec Load configuration template provided by the vehicle manufacturer for CAN bus Configuration template for the CAN bus...
  • Page 79 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE MOST25: MOST25 > Common Settings: Setting Description Default change Settings Change settings for control channel and common asynchronous channel simultaneously Enable Turn on logging for these channels Prevent Sleep Datalogger will not go into sleep mode as Mode long as there is activity on these channels Alias...
  • Page 80 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE MOST25 > Control Channel: Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name most25_control# Bus ID Additional ID for subsequent evaluation Prevent Sleep Datalogger will not go into sleep mode as Mode long as there is activity on this channel MOST25 >...
  • Page 81 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Ethernet: For X ML-Z7 with BroadR-Reach switch or spy, there are additional ORAYA settings available here. Ethernet > Settings: Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name ethernet# Bus ID Additional ID for subsequent evaluation...
  • Page 82 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE BroadR-Reach switch: Reset link Link state of each port is represented as a red or green traffic light. Click (1) to reset the link. Data Sink switch operation mode, the data are only recorded. Pass Through mode, the BroadR-Reach ports are combined as pairs to allow a bus connection between ECU and BroadR-Reach component, for...
  • Page 83 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE A VLAN-ID is assigned to each port. During data recording, this ID is inserted into the Ethernet frame as the outer VLAN tag, so the measurement contains information on which port the data were received. You can change the VLAN-ID for each port separately via the property brr_vlan_outer_vid# the category other.
  • Page 84 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Ethernet > Filter: Add pre-filter Increase pre-filter priority Delete pre-filter Decrease pre-filter priority Save pre-filter The filter is executed in two successive steps: Pre-filter MAC address ▪ Queue dispatching filter EtherType and VLAN ▪...
  • Page 85 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Priorities of pre-filters Change the priorities of the pre-filters with the buttons (4) and (5). The X Suite applies the first pre-filter from the top ORAYA that matches the condition. The other pre-filters are ignored.
  • Page 86 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Ethernet protocols: In this configuration section, you can add, update and delete GNLog and DLT channels. Both protocols are recorded via the LAN host ports or the BroadR-Reach interface.
  • Page 87 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name gnlog# or DLT# Bus ID Additional ID for subsequent evaluation Source TCP (GNLog, DLT) or UDP (only DLT) IP address and port of the ECU Default sets the port to 851 (GNLog) or 3490...
  • Page 88 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE VIDEO: Connect camera:  Connect the camera to one of the Ethernet log interfaces (N). (➔ Connections and controls)  Connect another Ethernet log interface (N) to one of the LAN host ports (E).
  • Page 89 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name video# Bus ID Text box Bus ID Additional ID for subsequent evaluation To control an IP camera default enters the sample configuration of a Basler camera...
  • Page 90 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Configure triggers:  On the header of the desired trigger action, click Add trigger (1).  Select the desired Trigger type (2).  Create a single condition or multiple combined conditions for this trigger.
  • Page 91 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagCCP: DiagCCP > Settings: Clear all settings Open selection file Edit CAN interface channel Settings Open A2L file Traffic light for the bus load Traffic light for the EPK check...
  • Page 92 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE PROTOCOL_CCP PROTOCOL_CCP_SPY The available modes (Master, Spy) depend on the activation of these licenses. Check in category Versions of system settings to verify which licenses are activated for your datalogger. (➔ Versions) Setting Description Default...
  • Page 93 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE A2L configuration:  Click Open A2L file (3) and select the description file that corresponds with the ECU.  The X Suite reads the A2L file and configures the CCP ORAYA connection accordingly.
  • Page 94 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagCCP > Filter: Show all signals Export signals Search box Display CCP main settings Refresh signal list Add polling channel* Display selected signals Status of the signal definition file Clear selected signals Prescaler* Import signals * Only if supported by the A2L file...
  • Page 95 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE To allow a later MDF export of the data without A2L file, generate a signal definition file in the Other category and save it, optionally encrypted, on the datalogger. (➔ Other) Status of the signal definition file (10) displays the current state of the file and changes its state by clicking:...
  • Page 96 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagCCP > Trigger: Add trigger Delete trigger Trigger type Move trigger up Edit trigger Move trigger down Here, you create conditions that trigger the following actions: Trigger action Description ccp.start Start CCP data recording ccp.stop Stop CCP data recording Start and stop without trigger conditions...
  • Page 97 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagCCP > Other: Show/hide A2L signals Additional signals Delete signal Signal selection Delete signal definition file To allow a later MDF export of the data without A2L file, generate a signal definition file as a reduced A2L file and save it, optionally encrypted, on the datalogger.
  • Page 98 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagCCP > Advanced: Add basic structure of the function Execute function Input data This category displays an overview of the configured event channels and allows the definition of a seed and key function for the encrypted communication with the ECU.
  • Page 99 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagXCP: DiagXCP > Settings: Clear all settings Open selection file Edit interface channel Settings Open A2L file Traffic light for the bus load Traffic light for the EPK check Engine RPM* * Only for angle-synchronous event channels...
  • Page 100 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE PROTOCOL_XCP_MASTER PROTOCOL_XCP_SPY PROTOCOL_XCP_ON_CAN PROTOCOL_XCP_ON_FLEXRAY The available modes (Master, Spy) and physical buses (CAN, FlexRay) depend on the activation of these licenses. Check in category Versions of system settings to verify which licenses are activated for your datalogger. (➔...
  • Page 101 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Meaning of the symbols for the available CAN or FlexRay channels: transmission-capable transmission-capable, but currently set to passive not transmission-capable (only for CAN) not enabled Edit interface channel (2) button, you can enable it, activate its transmission capability or change its baudrate if necessary.
  • Page 102 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Signal configuration:  Click Open selection file (5) and select a suitable XML, CFG or LAB file.  Click Signal selection and select the signals manually. (➔ Filter)  The X Suite calculates the expected percentage of the bus load ORAYA increase.
  • Page 103 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagXCP > Filter: Show all signals Export signals Search box Display XCP main settings Refresh signal list Add polling channel* Display selected signals Status of the signal definition file Clear selected signals Prescaler* Import signals Change column order...
  • Page 104 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE To allow a later MDF export of the data without A2L file, generate a signal definition file as a reduced A2L file in the Other category and save it, optionally encrypted, on the datalogger. (➔ Other) Status of the signal definition file (10) displays the current state of the file and changes its state by clicking:...
  • Page 105 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagXCP > Trigger: Add trigger Delete trigger Trigger type Move trigger up Edit trigger Move trigger down Here, you create conditions that trigger the following actions: Trigger action Description xcp.start Start XCP data recording xcp.stop Stop XCP data recording Start and stop without trigger conditions...
  • Page 106 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagXCP > Other: Show/hide A2L signals Additional signals Delete signal Signal selection Delete signal definition file To allow a later MDF export of the data without A2L file, generate a signal definition file as a reduced A2L file and save it, optionally encrypted, on the datalogger.
  • Page 107 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE DiagXCP > Advanced: Add basic structure of the function Execute function Input data This category consists of the following elements: Overview of the configured event channels ▪ Timeout values (changeable) ▪ FlexRay buffer configuration (partly changeable) ▪...
  • Page 108 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Create and test the seed and key function:  Click Add basic structure of the function (1).  Insert the algorithm that corresponds with the ECU.  Define the Input data (2) to test the function.
  • Page 109 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Event: This interface must be activated for proper functioning of: Triggers ▪ Snapshots ▪ the Button interface ▪ Event > Settings: Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name event#...
  • Page 110 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Event > Trigger: Add trigger Delete trigger Trigger type Move trigger up Edit trigger Move trigger down Here, you create trigger conditions that write custom event messages. Configure triggers:  Click Add trigger (1).
  • Page 111 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Button: Use this interface to define which actions are triggered by the following trigger types. Each trigger type is assigned a channel of the button interface as follows (➔ Connections and controls): trigger_button Pressing the trigger button (J) ▪...
  • Page 112 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Setting Description Default Enable Turn on logging for this channel Alias Freely selectable channel name trigger_button or wake_line Bus ID Additional ID for subsequent evaluation Prevent Sleep Datalogger will not go into sleep mode as Mode long as there is activity on this channel Send Event...
  • Page 113 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.5.3 Signal configuration In this section, you configure signals and define signal processing and triggers. Messages and signals The payload of a message consists of signals with variable bit length. Messages and signals are assigned names for easier handling.
  • Page 114 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Signal processing: Configured signal processing Add signal processing Add the desired signal processing to the list (1). This list is stored temporarily or permanently on the datalogger. DATA_BINNING This license is required for signal processing. Check in category Versions of system settings to verify...
  • Page 115 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Log: Save signal processing Cancel signal processing Add signal processing:  Select an already configured Signal. (➔ Settings)  Specify the Interval.  Click Save signal processing (1).  The log signal processing is stored on the datalogger. Interval of the log signal processing If you specify an interval, the last measured value of the signal is counted in this time range.
  • Page 116 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Count: Save signal processing Cancel signal processing Add signal processing count:  Specify a Binning name.  Select an already configured Signal. (➔ Settings)  Select from Assignment way which three out of five text boxes, i.e. Number of classes, Begin, End, Width...
  • Page 117 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Interval of count signal processing If you specify an interval, the first measured value of the signal is counted in this time range. If you do not set an interval (corresponding to a in the text box), each signal value is counted.
  • Page 118 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Edit or delete signal processing: Configured signal processing Edit signal processing Delete signal processing Edit signal processing:  Select the signal processing in the list (1).  Click Edit signal processing (3).
  • Page 119 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Trigger: Add trigger Delete trigger Trigger type Move trigger up Edit trigger Move trigger down Here, you create conditions that trigger the following actions: Trigger action Description logger.logstart Start log process logger.logstop Stop log process logger.shutdown...
  • Page 120: Resetting To Factory Defaults

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Resetting to factory defaults For unwanted or defective system or interface configurations, it is recommended to reset the datalogger back to its factory defaults.  In the Logger menu, click Reset configuration to factory settings reset the system configuration or one or all interfaces to their factory defaults.
  • Page 121: Data Recording

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Data recording Data may be recorded in two ways: Online mode ▪ The datalogger transmits received messages directly to a PC, where they are stored in log files. To do so, the datalogger must be connected to the PC.
  • Page 122 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Release connection to logger Open the latest created session or measurement in the Viewer tool Start online logging Start Hdd logging Trigger acoustic signal to identify datalogger Display settings Displays the current bus traffic Display settings (6) to customize the following: Path and filename (➔...
  • Page 123 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Release connection to logger Displays the current bus traffic Stop online logging Trigger acoustic signal to identify datalogger Start Hdd logging Set Trigger for later evaluation Online logging information is distributed over several tabs. The following table describes the general function of each tab and the options offered in the context menu when right-clicking.
  • Page 124 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Function and context menu Interface Summary of recorded messages and errors grouped by interfaces and channels Context menu: ▪ Show or hide columns ▪ Hide inactive interfaces or channels Message Summary of recorded messages and errors grouped by messages Context menu: ▪...
  • Page 125 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Messages and signals The payload of a message consists of signals with variable bit length. Messages and signals are assigned names for easier handling. Timemaster An additional column Timediff. is displayed when you set the Timemasters on a particular record.
  • Page 126 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.7.2 HDD mode In this mode, the datalogger saves to one of the following media: Internal storage medium (default) ▪ USB flash drive if Record on USB stick in the Hard Disk category is ▪...
  • Page 127 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE New sessions are created under the following conditions: The HDD recording is started manually by a trigger or via the ▪ Suite. ORAYA The datalogger is turned on or woken up and Autostart in the Hard...
  • Page 128 X2E-Native format are stored in various files with the same base name but different file extensions. (➔ X2E-Native) The master file with the file extension DLI serves as link. This file contains information about the included log interfaces and references to the corresponding binary files.
  • Page 129: Hdd-Download

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Hdd-Download This tool allows downloading log data stored on the datalogger storage medium.  Connect the datalogger to the PC. (➔ Connecting the datalogger to the PC)  Optionally: Connect a X ESU to the corresponding port (F).
  • Page 130 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Release connection to logger Display settings Start Hdd logging Open last used path in Windows Explorer Start download Show download statistics Change disk* * Only with connected X ORAYA Click Change disk (4) to change between the internal storage medium and a connected X ESU.
  • Page 131 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE There are different ways to select the log data to download: Edit menu: Select all Select none ▪ Sessions Measurements tabs ▪ Calendar ▪ Time range ▪ Sessions/Measurements: You can show and hide the Sessions tab in the settings.
  • Page 132 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Calendar: Displayed date and Zoom:  Filter the displayed measurements, for example, by default or streaming queue (a).  Specify a start date (b).  Choose between Week (c) as the displayed time unit. ...
  • Page 133 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Time range:  Specify start date (a) and start time (b) of the desired time range.  Specify the end date (c). Use the arrows (d) optionally to apply the start date or to jump one day forward or backward.
  • Page 134 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Settings:  Specify the Export settings. (➔ Export settings)  Specify the Output formats. (➔ Output formats selection) Load settings from datalogger If you have previously used the Export category to save client settings on the datalogger, then you can load these via this button.
  • Page 135: Viewer

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Viewer This tool allows display and analysis of records. No datalogger connection is necessary to do this.  Start the Viewer tool of the X Suite. (➔ Starting) ORAYA The subsequent view is divided into four panels, which can be resized at will: Data (1) ▪...
  • Page 136 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.9.1 Data This panel displays the record set of the opened measurement. Open measurement Display settings Close selected measurement Opened measurements Open measurement:  Click Open measurement (1) and select the DLI file. ...
  • Page 137 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Close measurement:  Click Close selected measurement (2).  In the File menu, click Close.  Right click the desired measurement tab and then on Close the file. Right-click the desired record to view further options in the context menu: Set timemaster ▪...
  • Page 138 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE On the right edge of the panel, there are two scroll bars that can be adjusted independently. Left-click (1) to specify whether scrolling is by row numbers or time. Right-click (1) to specify how many rows or how much time is scrolled per click on the double-arrow buttons (2).
  • Page 139 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.9.2 Information This panel displays information about active measurement and search results. Tabs: Info ▪ Detail ▪ Search ▪ Trace ▪ Signals ▪ Comment ▪ Info: This tab displays general information about all records for the open measurement.
  • Page 140 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Detail: This tab displays detailed information about the currently selected record. The display changes depending on the interface type. Data Data values Raw data Raw data values Right-click anywhere on the white or green background part of the user interface to select whether the underlying raw data (2) is also displayed alongside the data (1).
  • Page 141 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Search: This tab displays records found by search processes using the button since cursor. The button All since cursor can be found in the following panels and tabs: Information panel, Signals ▪...
  • Page 142 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Signals: Use this tab to search for specific signals in the records of the opened measurement. The right-side view is different depending on whether Show signal details (13) or Manage signal lists (12) is activated.
  • Page 143 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Display signal details (15):  Select a message in the signals overview (14) to view details for all signals of this message.  Select a signal to view details for this signal. Display signals graphically: ...
  • Page 144 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Manage signal lists (12) is activated: Manage signal lists Add signal to list Signals overview Delete signal from list Signal lists Find signal Add new signal list Draw signal Create new signal list: ...
  • Page 145 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.9.3 Search, filter and export Use this panel to search the open measurement according to different criteria, filter records and export them to other output formats. Tabs: Browse ▪ Event ▪ Find ▪...
  • Page 146 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Depending on the search criteria, the search condition is either unique or not. You will find one record at the most when searching by: Message number (7) ▪ Date and time (8) ▪...
  • Page 147 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE History Click History (14) to access the latest search conditions. This list is reset every time you exit the tool. Bookmarks To add a record to the bookmarks, right-click it in the Data panel and select the appropriate option.
  • Page 148 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Search: User this tab to build complex searches. Field Next Relation All since cursor Value Previous Add constraint Cancel Constraint expression  Select the Field (1) that you would like to add to your search. ...
  • Page 149 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Navigate between records:  Click Previous (8) to go to the previous record found.  Click Next (6) to go to the next record found.  Click All since cursor (7) to display all records of this message, starting at the current position, in a list.
  • Page 150 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Apply filter:  Add the desired filter.  Click Start (1).  Records in the Data panel are filtered. Cancel filter:  Click Cancel (2). Export: Use this tab to export the records to various output formats. Export settings Source region selection Output formats selection...
  • Page 151 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Source region selection: Whole measurements All records ▪ Fine zone Zone specified in the Overview tab of the ▪ Graphical output panel (➔ Overview) Custom region Region specified in the Data panel (➔...
  • Page 152 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.9.4 Graphical output This panel displays the open measurement graphically. Tabs: Overview ▪ Graphic ▪ Video ▪ Overview: This tab displays the timeline of the opened measurement. Icons represent events, bookmarks and search results. You can also specify a Fine zone to filter the records to display and export.
  • Page 153 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Graphic: This tab shows selected values of the open measurement as time curves. Display data graphically:  In the Data panel, right-click a record of the interface channel that you would like to see in graphical format. (➔ Data) ...
  • Page 154: Statistic

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.10 Statistic This tool allows the evaluation of statistical data during datalogger operation, also simultaneous to data recording.  Connect the datalogger to the PC. (➔ Connecting the datalogger to the PC) ...
  • Page 155 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE The buttons in the toolbar change to reflect the current state of the statistic display: Freeze statistic Continue statistic Display remote statistic counter Statistic since the start of the tool and connection to the datalogger Display local statistic counter Statistic since last click on...
  • Page 156: Convert

    ORAYA ORAYA UITE 5.11 Convert This tool allows converting the log data recorded in the X2E-Native output format into various formats. (➔ Output formats) No datalogger connection is necessary to do this.  Start the Convert tool of the X Suite.
  • Page 157 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Manually sort log files in the list:  Select a row in the list.  Click Move selection up (3).  Click Move selection down (4). Automatic sorting Start and stop times of log files are displayed in red color if shown out of chronological order in the list.
  • Page 158 Open result DLI file (10) to open the path of the converted files in the Windows Explorer. If you select the output format X2E-Native, you have the choice between opening the DLI files in the Explorer of directly in the Viewer tool for analysis purposes.
  • Page 159: Firmware-Update

     Connect to the desired datalogger. (➔ Connecting the datalogger) Release connection to logger Open SWU/XSWU file Start Hdd logging Launch firmware update Perform firmware update  Download the latest firmware version from the X2E-Wiki. (➔ X2E-Wiki)  Click Open SWU/XSWU file (3).  In the File...
  • Page 160 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Do not interrupt the update process Power supply interruptions can destroy the datalogger.  Do not interrupt the datalogger power supply while CAUTION updating the firmware.  Confirm the datalogger restart twice, if Ask before restart in the Option...
  • Page 161: Tk Commandline

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.13 TK Commandline This tool provides access to the X Toolkit, a collection of commands ORAYA optimized for script-oriented application.  Connect the datalogger to the PC. (➔ Connecting the datalogger to the PC) ...
  • Page 162 Scans the network for dataloggers XLogFile Starts data recording in online mode and writes log data in various output formats XConvFile Filters X2E-Native log files and converts them into different output formats XJoinFile Joins X2E-Native log files XFileInfo Displays information about X2E-Native log files...
  • Page 163: Common Elements

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.14 Common elements This section describes GUI elements used in different parts of the Suite albeit in substantially the same way. ORAYA This manual refers to subsections of this section as required. 5.14.1 Changing the numbering system For numerical values in text boxes, you can switch the display between three...
  • Page 164 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.14.2 Set bits In certain interface configuration categories, you specify the bytes of messages: Trigger ▪ Trigger ▪ Ethernet Filter ▪  Click an in the bottom row of a byte (1) once or twice to set the desired bit to 0 or 1.
  • Page 165 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.14.3 Export settings This control element can be found in the following tools: Configuration, Online-Logging, Hdd-Download, Viewer and Convert. Download from datalogger* Store sessions in separate files** Attributes Overwrite files Browse for folder * Only in Hdd-Download ** Only in...
  • Page 166 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.14.4 Output formats selection This control element can be found in the following tools: Configuration, Hdd-Download, Viewer and Convert. Activate Delete Output format Show log file of export filter Filter settings Export settings Interface filter Save this export setting...
  • Page 167 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Save export setting for later reuse:  Enter a name in the text box Export settings (8).  Click Save this export setting (9). Load export setting:  Select the desired export setting in Export settings (8).
  • Page 168 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.14.5 Signal selection This control element can be found in the following tools: Configuration Online-Logging. The right-side view is different depending on whether Show signal details (9) or Manage signal lists (8) is activated.
  • Page 169 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Display signal details (11):  Select a message in the signals overview (10) to view details for all signals of this message.  Select a signal to view details for this signal. Add signal: ...
  • Page 170 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Delete signal list:  Select the signal list (11).  Click Delete signal from list (14). Display signal from signal list (11) in the signals overview (10):  Select the signal in the signal list (11). ...
  • Page 171 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.14.6 Signal description settings This control element can be found in the following tools: Configuration, Online-Logging and Viewer. Here, load description files and assign them to signal groups. Supported description file types: ▪...
  • Page 172 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.14.7 Create trigger conditions You use this control element to configure general signal triggers or triggers of the VIDEO, DiagCCP, DiagXCP and Event interfaces. The following trigger types are available: Value compare Raise trigger if a single condition or combined ▪...
  • Page 173 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Add condition:  Select an already configured Signal (9). (➔ Settings)  Select the Relation (10) between signal and value.  Select the Relation type (11).  Depending on the relation type, specify the Raw value or the time (in ms).
  • Page 174 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE Apply conditions:  Select the Execution time.  If necessary, change the automatically generated Description.  Only for event triggers: Under Arguments, specify the payload (32 bit) and the ID (8 bit) of the event message to be sent.
  • Page 175 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.14.8 Graph View This control can be found in the following tools: Online-Logging, Hdd-Download and Viewer. Toolbar Time pointer area Timeline Red time pointer To the left Blue time pointer* To the right Green time pointer Graph name * Only in...
  • Page 176 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE The following table describes the control elements on the toolbar (1) from left to right. Symbol Function Zoom in Zoom out Adjust the zoom level so that the Fine zone is visible Adjust the zoom level so that the entire measurement is visible Switch between previous and current zoom level Change the visibility of the blue time pointer, which represents the...
  • Page 177: Output Formats

    The following table shows an overview of all output formats relevant for the Z7 datalogger that you can select when downloading and converting log data. Output format File extension Exported message types X2E-Native DLI/DLM/DLF/DLS X2E Ascii DLASC Carmen-Journal (V3.0) Wireshark PCAP PCAP Ethernet Most OP2 MOST25...
  • Page 178 Maximum file size of a binary file (DLF) in MB WriteStatistics Create statistics file (DLS) CreateZIP Store log files as a compressed ZIP archive 5.15.2 X2E Ascii Setting Description Default ShowTimestamp Write time stamp for each message ShowCounter Write counter for each message...
  • Page 179 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.15.5 MOST OP2 Setting Description Default NewOP2onMaxFileSizeReached Create a new file when max file size is reached MaxFileSize_MB (x) Maximum file size in MB 5.15.6 MOST IMG Setting Description Default NewIMGonMaxFileSizeReached Create a new file when max file size is reached MaxFileSize_MB (x)
  • Page 180 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.15.8 Vector ASC Setting Description Default NewASConMaxFileSizeReached Create a new file when max file size is reached MaxFileSize_MB (x) Maximum file size in MB WriteCarmenBusMapping Write number and corresponding alias of the interface channels for further processing by CARMEN UseEcosCompatMode Do not write falling edges of button...
  • Page 181 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.15.12 Raw for RS232/RawSocket Setting Description Default NewRAWonMaxFileSizeReached Create a new file when max file size is reached MaxFileSize_MB (x) Maximum file size in MB Extension ( x ) File extension TimestampPrefix Write timestamp prefix for each message...
  • Page 182 ANUAL Z7 | X ML-Z7 ORAYA ORAYA ORAYA UITE 5.15.15 Video Extractor Setting Description Default DoJPEG Write images in JPEG format DoMPEG Write videos in MPEG-2 format DoH264 Write videos in MPEG-4/H.264 format 5.15.16 MDF Export Setting Description Default a2l_file_alternative_path ( x ) Alternative path for A2L file TimezoneOffsets_min ( x ) Time difference to UTC in minutes:...
  • Page 183: Maintenance

    Safety defects due to incorrect accessories and spare parts Accessories and spare parts that have not been recommended by X2E GmbH negatively affect the safety, CAUTION functionality and precision of the datalogger. X2E GmbH shall assume no responsibility whatsoever or...
  • Page 184: Cleaning

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA AINTENANCE Cleaning Device damage due to pollution Avoid any contamination in plugs and sockets to ensure a reliable contact. CAUTION  Keep the datalogger clean. Device damage due to penetration of dust or liquids Dust or moisture inside the datalogger may cause abnormal behavior or destruction of the device.
  • Page 185: Repair

     Contact X2E GmbH should maintenance and repairs be required. Upon malfunction or defect, return the datalogger without any accessories to X2E GmbH. You can find the address on page 2 of this manual. Before submission, please take the following measures:  Clean the datalogger. (➔ Cleaning) ...
  • Page 186: Storage, Transport And Disposal

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA TORAGE TRANSPORT AND DISPOSAL Storage, transport and disposal Storage If the datalogger will remain unused for an extended time, we recommend storing it in the original packaging. Please note the following storage conditions: Air temperature Rel.
  • Page 187: Disposal

    Phone: +49 6349 99599 211 E-mail: sales@x2e.de If more than 10 devices are returned at the same time, X2E must be informed in advance by the customer via the above e-mail address. Old devices to be returned must be clearly marked by the customer with the words "Disposal"...
  • Page 188: Appendix

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX Appendix Technical data The following table provides an overview of technical data and properties of the datalogger. Property Value/Characteristic Timestamp resolution 100 ns for all interfaces Internal storage capacity Max. 480 GB Operating ambient temperature -40 to +65 °C Air humidity...
  • Page 189: Datalogger Pin Assignments

    ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX Datalogger pin assignments The following tables show the pin assignments of the log interfaces and of the power/trigger/wake port. Figures show the external view of the datalogger contacts. 8.2.1 10x CAN Function CAN 1 High CAN 1 Low CAN 2 High...
  • Page 190 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.2.2 4x CAN Function CAN 3 Low CAN 1 Low CAN 4 Low CAN 2 Low CAN 3 High D-SUB9, M CAN 4 High CAN 1 High CAN 2 High 8.2.3 1x Dual-FlexRay Function FR BM A FR BM B...
  • Page 191 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.2.5 24x LIN Function LIN 1 LIN 2 LIN 3 LIN 4 3M, 10250-5212 PL LIN 5 LIN 6 LIN 7 LIN 8 LIN 9 LIN 10 LIN 11 LIN 12 LIN 13 LIN 14 LIN 15 LIN 16...
  • Page 192 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.2.6 8x RS-232 Function RX 8 TX 8 RX 7 TX 7 3M, 10220-5212 PL RX 6 TX 6 RX 5 TX 5 RX 4 TX 4 TX 1 RX 1 TX 2 RX 2 RX 3 TX 3...
  • Page 193 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.2.8 6x Analog Function Channel 3- Channel 4+ Channel 4- Channel 5+ Channel 5- D-SUB15, M Channel 3+ Channel 6+ Channel 6- Channel 1- Channel 1+ Channel 2+ Channel 2-...
  • Page 194 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.2.9 12x BroadR-Reach switch Function BR 4 P BR 4 N BR 3 N BR 3 P 3M, 10236-5212 PL BR 9 P BR 9 N BR 10 P BR 10 N BR 7 P BR 7 N BR 11 P...
  • Page 195 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.2.11 Power/trigger/wake Function Wake Trigger/Wake Trigger...
  • Page 196: Cable Pin Assignments

    PPENDIX Cable pin assignments The following pin assignments refer to the cables manufactured by X2E GmbH: on the left, you see the connection on the datalogger side and on the right, one or more connectors in the measurement environment or to the power supply.
  • Page 197 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.3.2 4x CAN (x4) Function Function CAN 3 Low CAN # Low CAN 1 Low CAN # High CAN 4 Low CAN 2 Low CAN 3 High CAN 4 High CAN 1 High CAN 2 High 8.3.3 1x Dual-FlexRay...
  • Page 198 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.3.4 7x LIN (x9) Function Color Function LIN 1 yellow LIN # LIN 2 VBAT LIN 3 black LIN 4 LIN 5 LIN 6 LIN 7 VBAT...
  • Page 199 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.3.5 24x LIN (x26) Function Color Function LIN 1 yellow LIN # LIN 2 VBAT LIN 3 black LIN 4 LIN 5 LIN 6 LIN 7 LIN 8 LIN 9 LIN 10 LIN 11 LIN 12 LIN 13...
  • Page 200 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.3.6 8x RS-232 (x8) Function Function RX 8 RX # TX 8 TX # RX 7 TX 7 RX 6 TX 6 RX 5 TX 5 RX 4 TX 4 GND* TX 1 GND* RX 1 TX 2...
  • Page 201 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.3.7 4x PSI5 (x16) Function Color Function GND 2 Active # Active 2 Black GND # GND 1 Bus Passive # Active 1 Black Sink Passive # GND 3 / GND 4 Active 4 Active 3 Sink Passive 4...
  • Page 202 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.3.8 6x Analog (x12) Function Color Function Channel 3- Channel #+ Channel 4+ black Channel #- Channel 4- Channel 5+ Channel 5- Channel 3+ Channel 6+ Channel 6- Channel 1- Channel 1+ Channel 2+ Channel 2-...
  • Page 203 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.3.9 12x BroadR-Reach switch (x12) Function Function BR 4 P BR # N BR 4 N BR # P BR 3 N BR 3 P BR 9 P BR 9 N BR 10 P BR 10 N BR 7 P BR 7 N...
  • Page 204 ANUAL Z7 | X ML-Z7 ORAYA ORAYA PPENDIX 8.3.10 4x BroadR-Reach spy (x4) Function Function BR 3 P BR # N BR 3 N BR # P BR 2 P BR 2 N BR 1 P BR 1 N BR 4 P BR 4 N 8.3.11 Power/trigger/wake...
  • Page 208 X2E GmbH Grosse Ahlmühle 19 76865 Rohrbach GERMANY Phone +49 6349 99599 200 E-mail xoraya@x2e.de Internet www.x2e.de Wiki wiki.x2e.de...

This manual is also suitable for:

Xoraya z7

Table of Contents