Download Print this page

HBM SomatXR EX23-R Quick Start Manual page 2

Hide thumbs Also See for SomatXR EX23-R:

Advertisement

EX23-R Quick Start Guide
EX23-R PoE Switch
FRONT
BACK
Setting up the EX23-R
The EX23-R is designed to be used straight out of the box.
1. Connect the 1-NTX003 power supply or 1-KAB2115 power
pigtail cable from the power connector on the EX23-R to a
10-36 V
power source.
DC
NOTE
Connect only the red and black wires of the 1-KAB2115 cable. Do NOT
use a 1-KAB2110 cable to power the EX23-R from the CX23-R,
eDAQXR EXRCPU or eDAQXR-lite EXRLCPU.
2. Connect the desired devices to the Ethernet ports using
1-KAB2100, 1-KAB2106 or 1-KAB2107 Ethernet cables,
depending on the device.
CAUTION
Drawing PoE power lowers the maximum operating temperature. Please
refer to the data sheet for the exact de-rating specifications.
EX23-R Factory defaults
To reset to factory defaults, jumper port 1 to port 2 using a 1-KAB2107
cable and power cycle the unit.
NOTE
Reset to factory defaults will cause ports to auto negotiate. However,
Ports 5 and 6 must be manually configured to 100Mb full duplex (status
LED will be orange) for reliable PTP function. Contact HBM Customer
Service for assistance with manual configuration.
EX23-R Quick Start Guide
Configuring the EX23-R
1. Connect a PC to any open EX23-R port
using a 1-KAB2106 cable.
2. Open an internet browser and navigate to:
IP Config: 192.0.2.1/ip_config.htm or
Firmware: 192.0.2.1/upload.htm
3. Log on using the default credentials:
username: admin password: (blank)
EX23-R status LEDs
Power LED
Description
Off
Power input not in range
On
Unit is powered
Flashing (2 Hz)
Power error
Flashing (8 Hz)
Firmware update
Several issues can cause a power error:
Over temperature
n
Over voltage or over current input power
n
Internal power supply not working
n
Ethernet LED
Description
Off
No link
Green
Gigabit link is up
Orange
10 or 100 Mb link is up

Advertisement