Amvex VR-CIU2-F2D Operating And Maintenance Manual

Amvex VR-CIU2-F2D Operating And Maintenance Manual

Continuous / intermittent digital & analog vacuum regulator

Advertisement

Quick Links

OPERATING AND MAINTENANCE MANUAL
- CONTINUOUS / INTERMITTENT -
DIGITAL & ANALOG VACUUM REGULATOR
DIGITAL (D)
VR-CIU2-F2D
VR-I2U2-F2D
VR-PIU2-F2D
VR-PPU2-F2D
VR-NIU2-F2D
VR-NNU2-F2D
25B East Pearce St., Richmond Hill, ON L4B 2M9 Canada | Tel: 905.764.7736 | Fax: 905.764.7743 | www.amvex.com
®
Models Included:
ANALOG (A)
VR-CIU2-F2A
VR-I2U2-F2A
VR-PIU2-F2A
VR-PPU2-F2A
VR-NIU2-F2A
VR-NNU2-F2A
Rx ONLY
1111 Lakeside Drive, Gurnee, IL 60031-4099 | Tel: 1.800.448.0770 | Fax: 847.855.6300
1
0413
0413
www.ohiomedical.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VR-CIU2-F2D and is the answer not in the manual?

Questions and answers

Summary of Contents for Amvex VR-CIU2-F2D

  • Page 1 VR-NIU2-F2D VR-NIU2-F2A VR-NNU2-F2D VR-NNU2-F2A Rx ONLY 0413 0413 25B East Pearce St., Richmond Hill, ON L4B 2M9 Canada | Tel: 905.764.7736 | Fax: 905.764.7743 | www.amvex.com 1111 Lakeside Drive, Gurnee, IL 60031-4099 | Tel: 1.800.448.0770 | Fax: 847.855.6300 ® www.ohiomedical.com...
  • Page 3: Important Safety Instructions

    Warranty, repair of this device is not to be performed by anyone other than a qualifi ed profes- sional and done in strict accordance to the written instructions provided by Amvex. If this device is subject to improper maintenance, repair, use and/or abuse leading to malfunction of the device, replacement is the sole responsibility of the user.
  • Page 4: Intended Use

    NOTE: When a battery icon appears on the gauge it indicates that the battery is low. Please take the unit out of service immediately and contact an Amvex/Ohio Medical Customer Service Representative for battery replacement. If the low battery condition is not addressed and the battery becomes fully depleted, the gauge will not show any readout including the low battery icon or gauge pressure.
  • Page 5 Procedures Prior to Use List: The following tests are recommended prior to use on each patient. WARNING: If the Vacuum Regulator does not pass one or more of the following tests, it should be evaluated, repaired and/or replaced by a qualifi ed individual. The following tests must be done with a minimum supply vacuum of -53 kPa(-400 mmHg): 1.
  • Page 6 8. Once the desired cycle time has been reached, slide the Face Assembly [1] back on the Back Body [11] and re-insert the four Cover Screws [16]. 9. Amvex recommends that the user complete the Procedures Prior to Use List to assure Vacuum Regulator is operating correctly.
  • Page 7: Cleaning Instructions

    Cleaning Instructions 1. Connect the supply port of the Vacuum Regulator to the patient port of a collection canister. 2. Attach the vacuum port of the collection canister to a vacuum source. 3. Connect a hose from the patient port of the Regulator to be cleaned and place the other end into a container containing 100cc of a cold sterilant.
  • Page 8: Replacement Parts

    Ohio Medical Corporation. Any use other than that authorized by Ohio Medical Corporation is prohibited. Ohio Medical Corporation, the Ohio Medical logo, Amvex and the Amvex logo are registered trademarks of Ohio Medical Corporation. NFPA is a registered trademark of National Fire Protection Association Inc.