Page 1
P1/3 thru P2 Introduction Penguin Series PSS vertical 316L stainless steel pumps have a liquid temperature range of -30 degrees F to 211 degrees F. Temperatures greater than 211 degrees F but less than 250 degrees F are acceptable for non-caustic, non-hydrocarbon service.
Maintenance Instructions Recommended installation for optimal performance and endurance. DISCHARGE PIPE GATE VALVE (NOTE 3) CHECK VALVE CONCENTRIC REDUCER MAX. LIQUID LEVEL MIN. LIQUID LEVEL Pump Installation Install the pump vertically in-tank with the pump immersed in the liquid approximately half way and the motor facing upward on the tank lip or structural beam on top of the tank.
Page 3
Maintenance Instructions • Keep friction head to a minimum by making the discharge line short and direct with as few fittings as possible. • The outlet piping should be supported as close to the pump as possible, using pipe hangers or pipe supports. •...
Page 4
Installation & Operation Instructions Motor Bearing Lubrication/Change-out • No motor bearing lubrication is required on motors that are furnished without plugs or grease fittings. These units are provided with permanently lubricated sealed bearings. Motors provided with grease fittings should be lubricated according to the motor manufacturer’s lubrication frequency schedule.
Spare Parts SERIES PS VERTICAL 316SS PUMP SPARE PARTS P-1/3S- P-1/2S- P-3/4S- P-1S- P11/2S- P-2S- DESCRIPTION MAT’L 3/4 X 1/2 1 X 3/4 1 X 3/4 1-1/2 X 1 1-1/2 X 1 1-1/2 X 1 SHAFT EXTENSION 316 PS-130-01 PS-130-01 PS-340-01 PS-130-01 PS-130-01...