INTRODUCTION
micro poli is a wireless multifunction sensor, in compliance with the wireless bidirectional 868 MHz
protocol used by Ksenia Security. Inside a very small case characterized by an essential and minimalist
design, micro poli is much more than a simple magnetic contact.
micro poli is:
an anti-masking magnetic contact to detect the opening of doors and windows;
an inertial sensor to detect the vibrations of increasing intensity up to the breaking of glass/windows;
able to measure the inclination of the window/door frame it protects, it allows the management of any
type of window opening (casement window, tilt and turn window, bottom hung windows, etc.) which it
would otherwise be impossible with only the magnetic contact.
As anti-masking magnetic contact with two REEDs (long side/short side) inside the transmitter, it is
extremely suitable for any type of door or window frames thanks to the installation position of the magnet
with respect to the transmitter. It is also possible to activate only one REED to detect the opening of the
window, according to the type of installation; masking attempts by applying a more powerful magnet
outside the frame can be detected, in this case it triggers a masking signal while the opening of the contact
triggers a Zone Alarm.
As inertial sensor, thanks to the 3-Axis accelerometer based on MEMs technology, when the vibration
exceeds the programmed sensitivity threshold, it triggers an alarm.
As advanced sensor, thanks to the 3-Axis accelerometer, it measures the angle of inclination of the window
within which the zone is considered on idle and beyond which it triggers an alarm.
code R30049.110en
ed.12/2021
KSI5008000.301 - white
KSI5008000.302 - black
KSI5008000.304 - brown
www.kseniasecurity.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the micro poli and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ksenia micro poli

  • Page 1 KSI5008000.304 - brown INTRODUCTION micro poli is a wireless multifunction sensor, in compliance with the wireless bidirectional 868 MHz protocol used by Ksenia Security. Inside a very small case characterized by an essential and minimalist design, micro poli is much more than a simple magnetic contact.
  • Page 2: Technical Characteristics

    2 REEDs to detect the opening of doors and windows. Thanks to two REEDs placed in different positions inside the device, micro poli fits any type of frame and installation position; the double REEDs detect the masking attempts by applying a more powerful magnet outside the frame and trigger a masking signal.
  • Page 3: Installation

    3. if necessary, install the stackable shims for transmitter and magnet; 4. for positioning micro poli, please follow the instructions described below; 5. to fix the micro poli to the frame, use the adhesive strip provided or self-tapping/self-drilling screws, diameter 3.5mm, rounded cylindrical head;...
  • Page 4 Top view Base internal view with screws Back view with screws POSITIONING The transmitter can be installed in different positions, thanks to its two REEDs, as shown in the following image: Transmitter orientation long side short side Please find below some installation examples.
  • Page 5 Side-hung casement window • To use micro poli as a magnetic contact (figure A) place the transmitter on the frame and the magnet on the mobile door. Figure B shows an optional installation. • The distance between the magnet and the indicator on the transmitter must not exceed 10mm.
  • Page 6: Operating Distances

    Fixed glazing window • Place only the micro poli transmitter, without the magnet, directly on the glass (figure A) or on the frame (figure B). Operating distances On the mounting surface (not ferromagnetic), for all configurations and the axes of operation (x - y - z) based on how the device is installed.
  • Page 7 2. Replace the battery inside the upper cover Note: temperatures below +5 °C can cause the micro poli to report a false low battery indication. Operation below +5 °C will reduce the battery life significantly. Caution! Observe the correct polarity when installing battery.
  • Page 8 4. in a few seconds the icon of the radio signal level detected and other data will appear in the real time section, if correctly installed. The following images show an example of a micro poli real time section correctly acquired by the lares 4.0 control panel and the description of the values:...
  • Page 9 In case of installation on a casement window • micro poli has an anti-opening and removal tamper and the associated zone (or zones) generates a sabotage alarm if the device is opened or removed. Possibility to exclude the analysis of the tamper by disabling the sabotage.
  • Page 10 Summary table of Magnetic Contact Zone real time The real time of the zone (alarm / idle / masking) varies according to the REEDS contacts set up (long side or short side, identifiable by the indicators on the cover of the transmitter), and to the "Masking" parameter set up (valid for both REEDs contacts).
  • Page 11 5. in case of failure of the peripheral itself, on the Home page -> Faults and tampers section, the message “micro poli - Missing wireless peripheral” appears, it is even a link to click and open the related configuration page.