  • Page 1 Fixturlaser EVO Fixturlaser EVO ©2017 VibrAlign, Inc. Q U I C K T I P S...
  • Page 2: Rough Alignment

    Fixturlaser EVO P R E - A L I G N M E N T 1. Rough Alignment • Vertical: Place scale or straightedge on highest hub and raise or lower the movable shaft to within 20 mils (0.020”) of the stationary hub.
  • Page 3 Fixturlaser EVO P R E - A L I G N M E N T Bolt Tightening Sequence 4. Make a Final Soft Foot Correction Loosen one bolt at a time and check for soft foot with a 2 mil (0.002”) shim or feeler gauge.
  • Page 4 Fixturlaser EVO S E T Set Up Turn on the EVO Display Unit. Mount the ‘S’ sensor on the stationary shaft or coupling hub and hand tighten the nut. Turn the sensor on by pressing the power button on the Bluetooth module.
  • Page 5: Enter Dimensions

    Fixturlaser EVO M E A S U R E Using the wrench, tighten the nuts another half turn. Enter Dimensions Starting on the left side of the screen display, touch the dimension entry block. Enter the indicated dimensions to the nearest 1/8” using the keypad.
  • Page 6 Fixturlaser EVO M E A S U R E Rotate the sensors to the 12:00 position, being sure they move outside the red portion of the circle on the screen. Press the measurement button again to take the second measurement.
  • Page 7: Evaluating The Results

    Fixturlaser EVO M E A S U R E The results will be displayed on screen. Evaluating the Results Vertical results are displayed at the top of the screen, horizontal results at the bottom. Green coupling icons indicate values which are in tolerance.
  • Page 8 Fixturlaser EVO C O R R E C T I O N Using the Verti-Zontal Process ™ First Correct the Vertical Misalignment Press the shim icon in the bottom right corner of the screen. Then press it again on the confirmation pop-up screen.
  • Page 9 Fixturlaser EVO C O R R E C T I O N If the sensors are not in proper position, values will not be displayed and the sensor position will be represented by a red circle. Make the largest adjustment first. The arrows indicate the direction of adjustment.
  • Page 10 Fixturlaser EVO R E - M E A S U R E & D O C U M E N T Re-Measure Press the re-measure button, then press it again on the confirmation pop-up screen. Re-measure to verify the results are within tolerance.
  • Page 11 Fixturlaser EVO VibrAlign is committed to helping you perform precise alignments. View Our Following Resources: • Training training.vibralign.com • VibrAlign Blog vibralign.com/blog • The Alignment Store shaftalignment.net • Videos youtube.com/vibralign • Free Alignment Apps vibralign.com/alignment-tools/apps Stay Connected: Like Us on Facebook facebook.com/VibrAlignUSA...
  • Page 12 Fixturlaser EVO Version 2.0 www.vibralign.com 800-379-2250 530 G Southlake Blvd. Richmond, VA 23236 Phone (800) 379-2250 Fax (804) 379-0189 ©2017 VibrAlign, Inc.