8
Self clean mode
This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling
/ dry / AUTO (cooling) mode to keep the indoor unit clean.
The self clean time varies with the cooling / dry / Auto (cooling) operation time as follows.
•
Cooling / dry / Auto (cooling) operation time
Less than 10 minutes
10 minutes to less than 1 hour
More than 1 hour
"
" is displayed on the remote controller during self clean operation.
•
To stop self clean forcibly, push
CAUTION
The fan continues to run even after
•
This is normal because the self clean mode is in progress.
The louvers open slightly and are directed horizontally during self clean, and they close when the self clean is
•
completed.
The operation lamp (LED) does not light during the self clean mode (function).
•
The self clean mode (function) cannot clean the room or remove the already existing mold and dust inside the
•
indoor unit.
To cancel the self clean function, consult the dealer.
•
25-EN
self clean time
No self clean operation
1 hour
2 hours
button twice in succession.
button is pushed to stop operation in some modes.
– 13 –
9
Advanced settings
How to set up swing type
3
1
Push
for at least four seconds when
the air conditioner is not working.
•
, symbol, and numbers flash.
2
Select an indoor unit to be set by pushing
(left side of the button).
•
Each time you push the button, unit numbers
change as follows:
UNIT No.
UNIT No.
1-1
1-2
Not
UNIT No.
display
1-4
The fan of the selected unit runs and the louvers
start swinging.
3
Select a swing type by pushing TIME
buttons.
Swing setup code
Swing setup code
Swing of louvers
Standard swing
0001
(Factory default)
0002
Dual swing
0003
Cycle swing
5
4
1
2
CAUTION
Do not set the swing setup code to "0000".
(This setting may cause a failure of the louvers.)
4
Push the
button.
5
Push the
button to finish the setting.
UNIT No.
1-3
26-EN