Optic-electronic pir motion detector

Advertisement

6 INSTALLATION PLACE
1) Recommended installation height is 2.4-2.5 m.
2) Install detector on bearing walls and carri-
ers.
3) Alarm loop and power supply wires should
be located far from power cables.
To eliminate false alarm hazards
It is recommended to close all doors, air-vents,
switch off fans, air-conditioners and other
sources of intense air flows in the room during
protection
period.
Not recommended installation locations
7 INSTALLATION PROCEDURE
1) Remove cover
2) Remove PCB
3) Select installation
4) Installation on the
method 4) or 5)
wall
5) Installation
in
the
corner using bracket
6) Insert
PCB
and
perform wiring (see
sec.8)
7) Perform TEST-pass (see sec.9)
8 WIRING
Perform
wiring to detector`s terminals
accordance with control panel operating manual.
RELAY – terminals for detector connection to
alarm loop;
+12V, GND – power supply terminals.
9 TEST-PASS
1) Remove jumper from Ind plug. Install jumper
on Sens plug.
2) Close detector.
3) Power detector ON. LED starts flash during
60 sec.
4)
To detect sensitive zones carry out TEST-
pass
in the secured zone
with the speed of 0,3
m/sec.
Stop
upon
detection
(indicator lights up for 2sec),
mark position, then make a
step
back
and
continue
moving forward.
Repeat TEST-pass
inversely.
10 WARRANTY
The operation warranty period is 5 years from
the date of operation start-up but no longer than
5 years 6 months from the date of manufactur-
ing
subject to the requirements of Operating
Manual.